Hager EE855 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hager EE855 (4 Seiten) in der Kategorie Bewegungsmelder. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
6 m ( 140°)α
8 m ( 200°)α
6 m ( 140°)α
8 m ( 200°)α
α
Description
Detection zone
Installation
Setting
Shutters
Plate for wall  xing
Swivelling detection head
Connection by PIN system
(4 plug-in pins)
Vertical adjustment
α = 360°
Fixed time
(length of time
of lighting)
Luminosity Sensitivity
(modification
of the range)
Setting potentiometers
EE85. α = 140°
EE86. α = 200°
The optimal height of installation is 2.5 m.
The detection field must remain free.
8 m 16 m
2,5 m
0,5 m
16 m
4 m
LED A LED B
Accessories for corner  xing
For use in Australia and New Zealand
Caution!
This device is to be installed only by a professional
electrician tter according to local applicable
installation standards.
Do not plug in or unplug this product when it is live.
DETECTOR 140°
EE850 White
EE851 Charcoal
DETECTOR 220°
EE860 White
EE861 Charcoal
ACCESSORY FOR
CORNER FIXING
EE855 White
EE856 CharcoalE857
Alu
6E7578.C1
6E7578.C
EE85., EE86.
izMotion detectors comfort 140°, 220°
Testing and validating
the detection zone
Put the potentiometer on Test mode and if 2
necessary, use the shutters to define the detection
zone.
The Test mode is available for 3 min. Every
movement detected switches on the light for 1s.
After 3 min without detection of movement, the
product returns to normal operation.
Limiting the detection zone
You can limit the detection zone by using the
shutters provided or by tilting the head.
“Normal” operation (on/off)
The lighting is activated whenever the level of
luminosity defined by the potentiometer is 2
judged to be insufficient and a movement is
detected.
After detection, the light stays on for the length
of time predefined by the potentiometer 1.
The fixed timing is reset after each detection.
Please note: when the potentiometer is on “auto
test”, the settings are predefined.
Control by timer
An impulse is generated every 10 s whenever the
level of luminosity is judged to be insufcient and
a movement is detected when the potentiometer
1 is on V.
This pulse mode is not suitable for connections to
power devices (except at low power loads).
Using the remote control (option, ref.
EE806)
The detector receives instructions from the remote
control when the Lux potentiometer is on the “auto
test” position.
If the potentiometer is put on another value, the
local setting resumes.
The LED B of the detector lights up to confirm the
signal with the remote control.
It flashes quickly for 2 s when an instruction is
received and 5 s for a reset.
When an instruction is not authorised, the LED
lights up for 1 s.
The available settings are:
- fixed time
- level of luminosity
- sensitivity
- on / off
- holidays (simulation of presence)
- activation of the detection A.
Operating precautions
In order to obtain optimal detection conditions, it is recommended that the following advice:
- the detection is sensitive to solar radiation and bad weather. Detection performance is optimal up to
35 °C and above 40 °C.
- It is preferable to maintain à distance of 1 m. between a light source and the detector.
When mounting on a box, make sure that you do not distort the wall plate through excessive tightening
of the screws.
Montage
Surface-mounting or ceiling-mounted :
- x the wall plate using the screws provided
- connect the wall plate terminal block (see cabling plans in annex)
- fully insert the detector on the wall plate
- tighten the screws to ensure the product is sealed.
For corner xing, the wall plate is to be xed between the accessory and the detector.
Cable entry (breakable partitions) are possible:
- by the back (box mounting) or by the bottom.
Product presentation
and operating principles
This detector allows automatic control of a
light source for a dened length of time when a
movement is detected in the surveillance zone.
The LED A indicates a movement. It is inhibited by
default except in Test mode.
Settings and Test
The detectors have 2 modes of operation:
Fixed time and Control by timer.
Power supply
The detector switches the light on for 40 s.
After 40 s, it activates the Normal mode.
Ateha raceways
ref. ATA 12200
or ATA 63000
Wiring and connections (provide installation with xed wiring)
Action Settings Potentiometer
Use Auto settings
(factory) or set by
the remote control
to switch the light
automatically for a
given time.
Auto Settings
Put the Lux potentiometer on
“auto test”.
The settings are predefined:
Lux = o
(operating at night only)
time = 3 min,
sensitivity = max.
Remote control settings
(Manual Settings inhibited).
Automatically switch
on the light for a
defined time.
Installer settings
Control a timer, a bell
etc.
Impuls V
Auto settings are usable with
time = 1s. (cannot be changed)
Test and validate the
detection zone.
Test mode
Move the potentiometer 2 to
“auto test”. On this position, the
remote control can be used.
Adjust the sensitivity. Allows setting the range
to avoid disturbance.
6E7578.C2
6E7578.C3
6 m ( 140°)α
8 m ( 200°)α
6 m ( 140°)α
8 m ( 200°)α
α
Beschrijving
Detectiezone
Installatie
Instelling
Afdekplaten
Wandmontageplaat
Draaibare detectiekop
Aansluiting d.m.v. PEN-systeem
(4 insteekbare pennen)
Verticale instelling
α = 360°
Lichtsterkte Gevoeligheid
(wijziging van het
bereik)
Instelpotentiometers
EE85. α = 140°
EE86. α = 200°
De optimale montagehoogte bedraagt 2,5 m.
Het detectieveld moet vrij zijn.
8 m 16 m
2,5 m
0,5 m
16 m
4 m
LED A LED B
Toebehoren voor hoekmontage
6E7578.C
EE85., EE86.
ziBewegingsmelders comfort
140°, 22
Tijdvertraging
(verlichtingsduur)
Opgelet!
Het toestel mag alleen door een elektroinstallateur
worden geïnstalleerd volgens de installatienormen
die van toepassing zijn in het land.
De contactpennen van het product niet vast- of
loskoppelen wanneer het onder spanning staat.
140°-BEWEGINGSMELDER
EE850 Wit
EE851 Zwart
220°-BEWEGINGSMELDER
EE860 Wit
EE861 Zwart
TOEBEHOREN VOOR
HOEKMONTAGE
EE855 Wit
EE856 ZwartE


Produktspezifikationen

Marke: Hager
Kategorie: Bewegungsmelder
Modell: EE855

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager EE855 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Bewegungsmelder Hager

Bedienungsanleitung Bewegungsmelder

Neueste Bedienungsanleitung für -Kategorien-