Vemer Sensor 360L Bedienungsanleitung

Vemer Bewegungsmelder Sensor 360L

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Vemer Sensor 360L (1 Seiten) in der Kategorie Bewegungsmelder. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/1
User manual
Movement detector
Read all instructions carefully
The
Sensor-360L
proximity switch is an electronic switching device containing
micro-disconnection (μ) of opening between the contacts (EN 60669-2-1).
The output circuit is activated when a heat source moves in front of the device
and is deactivated when no movement is intercepted, after a settable period of time.
The movement detector circuit only reacts when the light conditions are below
the selected level.
SAFETY WARNINGS
During installation and operation of the device, comply with the following
instructions:
1) The device must be installed by a skilled person, in strict compliance with
the connection diagrams
2) Do not power on or connect the device if any part of it is damaged
3) In the building where the device is to be installed, there must be a switch
and a device for protection from overloads
4) Before touching the terminals make sure that the conductors to be
connected to the device are not live.
Code Model Description
VE787800 Sensor-360L Movement detector 360° - ceiling mounting
VE787900 TC.Sensor Infrared remote control for Sensor-360L
TECHNICAL CHARACTERISTICS
Power supply: 230V AC 50Hz
Breaking capacity: 10A 250V AC (resistive load)
Consumption: 8VA (1W)
Range of brightness: from 10 to 1000 lux
Time range: from 1 second to 10 minutes (approximate)
Detection angle: 36
Maximum installation height: 12 meters
Blue LED to indicate the status of the device
Operating temperature: -10 °C ÷ +40°C
Protection degree: IP44
Insulation: class II
INSTALLATION
The device must be installed far from inductive loads (motors, transformers,
telephone antennas, transformer plants, industrial machinery, etc.) as
especially strong magnetic elds may alter operation.
The device must also be protected from rain and sunlight, it must not be
placed near lights, near devices that are subject to temperature changes
(heating, air conditioning) and far from highly reective surfaces.
The detection area directly depends on the installation height; in particular, an
installation at 12 meters height, permits to detection a eld of 8.5 meters ray.
Dimensions
Ø140 43
68
PUTTING INTO SERVICE
Detection range adjustment
To set the detection area:
1. Rotate the selector to the maximum position, the SENS LUX selector
in position and the selector in position TIME
2. Then move within the limits of the detection range to check coverage.
If necessary, use the selector to reduce the limits of the detection eld.SENS
Sensor 360L is supplied with a detection area limiter , which is divided into 8
sectors with three heights. Each sector covers an angle of 45°.
The limiter of area must not be used if you want to allow the detection over the
36 area. Otherwise, cut the limiter according to the area to be covered and place
it on the sensor 360L lens.
Luminosity adjustment
The device activates the output circuit only when the lighting conditions are
below the level selected with the selector.LUX
Rotate the selector to the position so that the device works in any light LUX
condition; vice versa, rotate it to the position to make the device work only in
low light conditions.
To set an intermediate brightness level:
1. Rotate the selector to the LUX position and wait for the the desired level
of brightness
2. Then begin to rotate the selector towards higher values until, movingLUX
within the detection range, the output circuit is activated
Note: brightness measurement occurs only when the output circuit is open.
Intervention time adjustment
The intervention time indicates how long the output circuit remains open (relay
ON) following a detection.
Use the selector to adjust the intervention time:TIME
- impulse function : 1 second ON, 4 seconds OFF (minimum time)
- 10 or 30 seconds
- 1, 2, 3, 5 or 10 minutes (maximum time)
The timings from 10 seconds to 10 minutes are repeated at each detection.
At the end of the adjustment operations, replace the front cover in its seat,
taking care to insert the teeth of the cover in the appropriate seats and turn it
clockwise.
The adjustments made with the selectors have an effect on the device from the
moment you leave the detection area and wait for the circuit to open.
The status of the device is indicated by the blue LED:
- permanently on: output circuit closed (relay ON)
- ashing: the lighting conditions are below the set level.
The device is in standby waiting for detection
- off: the luminosity conditions are above the set level
12 m
Ø17 m
Connection diagram
L'L
L
N
N
230 V~
µ
1000 VA
2200 W
2000 VA
1200 VA
2200 W
500 VA
900 VA
The sensitivity is instead inuenced by the environment temperature
(the higher the temperature, the worse the sensitivity) and by the direction
of the movement to be detected.
GREATER SENSITIVITY
direction of
movement
direction of
movement
LESS SENSITIVITY
PROGRAMMING WITH THE REMOTE CONTROL TC.SENSOR
The remote control
TC.SENSOR
allows remote
programming (max. 8 m) of the installed detector,
without the need to intervene directly on the device
selectors and therefore without the use of stairs.
When the
Sensor-360L
receives a signal from the
remote control, the blue LED ashes for a moment.
Test mode
Allows you to check the detection of each movement
detector.
Press the button and move inside the detection
area and check its coverage.
In this mode, the proximity switch detection action
occurs regardless of the brightness.
If the mode is not changed manually, after 5
minutes it will switch to mode.AUTO
Auto mode
To program the automatic operation of the movement detector, press the
button and then select the time ( ) for the system to be switched on.TIME 1
You can select between (1 second ON and 4 seconds OFF), 10 seconds, 30
seconds, 1 minute, 2 minutes, 3 minutes, 5 minutes or 10 minutes.
Then you select the luminosity (value below which the detection of the LUX
movement detector will take place) being able to choose one of these values:
(detection only at night), 100 Lux, 500 Lux or (detection in any situation
of luminosity both during the day than at night).
To set the sensitivity choose one of the following values: 20%SENS
(minimum sensitivity), 50%, 75% or 100% (maximum sensitivity).
TC.Sensor has an internal memory for saving the last set of parameters set.
This allows you to replicate the programming of parameters on multiple
Sensor-360L, simply by pressing the “Copy” button.
SPECIAL programmings MODES
Mode 5h ON
Press so that it stays on continuously for 5 hours to allow for cleaning,
maintenance, etc. After this time has elapsed, it will automatically switch
to AUTO mode.
Holiday mode
The holiday mode means that, during long periods of absence, our system
simulates a daily presence. When programming this function,
the presence detector will turn on the system for one hour when the selected
lighting conditions occur; after this period of time it will carry out random
ignitions over the next two hours with ignition operations varying between 5
and 15 minutes.
Alarm mode
With the function the movement detector, after the detection of a “Alarm”
movement, it will activate the system with an on-off alarm sequence of 1
second for a duration of 30 seconds.
During the last 3 seconds, the on-off sequence will happen every 0.5 seconds.
REFERENCE STANDARDS
Conformity to the EU directives:
2014/35/EU (LVD)
2014/30/EU (EMCD)
is declared with reference to harmonized standard:
EN 60669-2-1
ISCOM084-2106
Mod. Sensor-360L
Description
2
3
1
4
5
6
7
Fixing base
Terminal block
Cable entries
Sensor
Selectors
Front cover
Detection area limiter
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.


Produktspezifikationen

Marke: Vemer
Kategorie: Bewegungsmelder
Modell: Sensor 360L

Brauchst du Hilfe?

Wenn Sie Hilfe mit Vemer Sensor 360L benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Bewegungsmelder Vemer

Bedienungsanleitung Bewegungsmelder

Neueste Bedienungsanleitung für -Kategorien-