Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA
773.869.1234 (USA) • 773.869.1212 (International)
www.tripplite.com
Important Safety Instructions 2
Installation 3
Basic Operation 5
Battery Replacement 11
Storage and Service 11
SmartOnline™
True On-Line Tower UPS Systems
Warranty Registration 12
Español
Français 25
13
Copyright ©2009 Tripp Lite. All rights reserved. SmartOnline
™ is a trademark of Tripp Lite.
Troubleshooting 9
Warranty
Registration:
register online today for a chance
to win a FREE Tripp Lite product—
www.tripplite.com/warranty
Not suitable for mobile applications.
2
UPS Location Warnings
• InstallyourUPSindoors,awayfromexcessmoistureorheat,conductivecontaminants,
dustordirectsunlight.
• Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF(0ºCand
40ºC).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.
• Donotmountunitwithitsfrontorrearpanelfacingdown(atanyangle).
 Mountinginthismannerwillseriouslyinhibittheunit’sinternalcooling,eventually
 causingproductdamagenotcoveredunderwarranty.
UPS Connection Warnings
• ConnectyourUPSdirectlytoaproperlygroundedACpoweroutlet.Donotplugthe
UPSintoitself;thiswilldamagetheUPS.
• DonotmodifytheUPS'splug,anddonotuseanadapterthatwouldeliminatetheUPS’s
groundconnection.
• DonotuseextensioncordstoconnecttheUPStoanACoutlet.Yourwarrantywillbe
voidedifanythingotherthanTrippLitesurgesuppressorsareusedtoconnectyourUPS
to an outlet.
• IftheUPSreceivespowerfromamotor-poweredACgenerator,thegeneratormust
provideclean,filtered,computer-gradeoutput.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentorto
significantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethis
equipmentinthepresenceofaflammableanestheticmixturewithair,oxygenornitrous
oxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.This
mightdamagetheUPSandwillvoidthesurgesuppressorandUPSwarranties.
Battery Warnings
Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.
Observeproperprecautions.Donotdisposeofthebatteriesinafire.DonotopentheUPS
orbatteries.Donotshortorbridgethebatteryterminalswithanyobject.Unplugandturn
offtheUPSbeforeperformingbatteryreplacement.Usetoolswithinsulatedhandles.
Therearenouser-serviceablepartsinsidetheUPS.Batteryreplacementshouldbe
performedonlybyauthorizedservicepersonnelusingthesamenumberandtypeof
batteries(SealedLead-Acid).Thebatteriesarerecyclable.Refertoyourlocalcodesfor
disposalrequirementsorintheUSAonlycall1-800-SAV-LEADor1-800-8-BATTERY
(1-800-822-8837)orvisitwww.rbrc.comforrecyclinginformation.TrippLiteoffersa
completelineofUPSSystemReplacementBatteryCartridges(R.B.C.).VisitTrippLiteon
theWebatwww.tripplite.com/support/battery/index.cfmtolocatethespecificreplacement
batteryforyourUPS.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation,operationandstorageofallTrippLiteUPSSystems.Failuretoheedthese
warningswillvoidyourwarranty.
2
Important Safety Instructions
1
2
3
1
33
Important Safety Instructions
Connection and Start-Up
Plug your UPS’s line cord into an
electrical outlet.
Your UPS must be connected to a dedicated
circuit of sufficient amperage.Note,however,
that the select models may be fitted with
differentplugtypes.Refertothe“OPRating/
PlugRating”chartprinted onthetopof your
UPS.
OnceyourUPSisplugged in,thefanandall
IndicatorLightswillturnON.The“LINE”and
“LOADACTIVEMETER”LEDswillilluminate
andtheUPSwillemitabeeptoindicatenormal
operation. However, power is not supplied to
your UPS’sAC outletsuntil theUPS isturned
on.
Plug your equipment into your UPS.
Your UPS is designed to support computer
equipmentonly.YouwilloverloadyourUPSif
you connect household appliances or laser
printerstotheUPS'soutlets.
Turn your UPS ON:
• Pressthe“ON/TEST”Button
• Holditforseveralsecondsuntilyou
 hearabeep
• Releaseit
Your UPS will begin providing AC power to its outlets.
The “ON LINE” LED will illuminate.
Your UPS will function properly without these
connections.
Phone Line or Phone/Network
Line Surge Suppression
Your UPS has jacks which protect against
surges on a phone or network line.* Using
appropriate network cords connect your wall
jack to the UPS jack marked “IN.” Connect
your equipment to the UPS jack marked
“OUT.”Makesuretheequipmentyouconnect
to the UPS's jacks is also protected against
surgesontheACline.
*NotcompatiblewithPoE(PowerOverEthernet)applications.
Your model may differ.
1
2
3
Your model
may differ.
Installation
Optional Connections
1
Your model may differ.


Produktspezifikationen

Marke: Tripp Lite
Kategorie: Unterbrechungsfreies Stromversorgungssystem
Modell: SU1000XLA
Akustische Signale: Ja
Breite: 171.4 mm
Tiefe: 336.6 mm
Gewicht: 13520 g
Produktfarbe: Schwarz
Höhe: 254 mm
Stecker: NEMA 5-15P
Verpackungsbreite: 246.4 mm
Verpackungstiefe: 454.7 mm
Verpackungshöhe: 353.1 mm
Paketgewicht: 15100 g
Ursprungsland: China
Anzahl Produkte pro Versandkarton: 1 StĂĽck(e)
Gewicht Versandkarton: 15100 g
Länge des Versandkartons: 454.7 mm
Breite des Versandkartons: 246.4 mm
Höhe des Versandkartons: 353.1 mm
Formfaktor: Tower
Ausgangsleistung: 800 W
Nachhaltigkeitszertifikate: RoHS
Eingangsfrequenz: - Hz
Anzahl der AC-Ausgänge: 6 AC-Ausgänge
USV-Topologie: Doppelwandler (Online)
Eingangs-Betriebsspannung (min): 100 V
Eingangs-Betriebsspannung (max): 120 V
Ausgangskapazität: 1 kVA
Ausgangs-Betriebsspannung (min): 100 V
Ausgangs-Betriebsspannung (max): 120 V
AC-Steckertypen: NEMA 5–15R
Typische Backup-Zeit bei halber Belastung: 14 min
Typische Backup-Zeit bei voller Belastung: 4.5 min
Hot-Swap-Batterie: Ja
Ausgang AnschlĂĽsse: 6x 5-15R

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tripp Lite SU1000XLA benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem Tripp Lite

Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem

Neueste Bedienungsanleitung fĂĽr -Kategorien-