2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings may
affect the warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or
direct sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F
(0Âş C and 40Âş C).
• Leave adequate space around all sides of the UPS for proper ventilation.
• Only set the UPS upright on a sturdy flat surface. Do not block fans or ventilation holes, as this will
seriously inhibit the unit's internal cooling and cause product damage not covered under warranty.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself;
this will damage the UPS.
• Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS ground
connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide clean,
ltered, computer-grade output.
• The mains socket outlet that supplies the UPS should be easily accessible and located near the
UPS.
Equipment Connection Warnings
Short Circuit backup protection and overcurrent protection is provided by the
building installation.
To reduce the risk of re, connect only to a circuit provided branch circuit
overcurrent protection. The plug on the power supply cord is intended to serve
as the disconnect device. Be sure the socket-outlet is installed near the
equipment and is made easily accessible.
• Use of this equipment in life support applications where failure of this equipment can reasonably
be expected to cause the failure of the life support equipment or to signicantly affect its safety or
effectiveness is not recommended.
• Do not connect surge protectors or extension cords to the output of your UPS. This might damage
the UPS and may affect the surge protector and UPS warranties.
• Connect the UPS to an outlet that is adequately protected against excess currents, short circuits
and earth faults as part of the building installation.
Important Safety Instructions
18-07-252-93388F.indb 2 10/3/2018 10:10:23 AM
3
Important Safety Instructions
Battery Warnings
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe
proper precautions. Do not dispose of the batteries in a re. Do not open the UPS or batteries.
Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before
performing battery replacement. Use tools with insulated handles. There are no user-serviceable
parts inside the UPS. Battery replacement should be performed only by authorized service
personnel using the same number and type of batteries (Sealed Lead-Acid).
The batteries are recyclable. Refer to your local codes for disposal requirements or visit
http://www.tripplite.com/support/recycling-program for recycling information. Tripp Lite offers a
complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the
Web at http://www.tripplite.com/products/battery-nder/ to locate the specic replacement
battery for your UPS.
CAUTION: A battery can present a risk of electrical shock and high short-circuit
current. Contact with any part of a grounded battery can result in electrical shock.
The following precautions should be observed when working on batteries:
• Remove watches, rings or other metal objects.
• Use tools with insulated handles.
• Wear rubber gloves and boots.
• Do not lay tools or metal parts on top of batteries.
• Disconnect the charging source and load prior to installing or maintaining the battery.
• Remove battery grounds during installation and maintenance to reduce likelihood of
shock.
• Remove the connection from ground if any part of the battery is determined to be
grounded.
• Unplug the UPS from the AC mains receptacle. Disconnect all cables, including the
equipment plugged into the UPS.
• Servicing of batteries should be performed or supervised by personnel knowledgeable
about batteries and required precautions.
• When replacing batteries, replace with the same type and number of batteries or battery
packs.
• CAUTION: Do not dispose of batteries in a fire. The batteries may explode.
• CAUTION: Do not open or mutilate batteries. Released electrolyte is harmful to the skin
and eyes. It may be toxic.
UPS and Battery Recycling
Tripp Lite products use sealed lead-acid batteries, which are highly recyclable.
Call Tripp Lite at 1.773.869.1234 or visit www.tripplite.com/support/recycling-program for
more information on recycling the batteries or any other Tripp Lite product. Please refer to
local codes for disposal requirements.
18-07-252-93388F.indb 3 10/3/2018 10:10:23 AM


Produktspezifikationen

Marke: Tripp Lite
Kategorie: Unterbrechungsfreies Stromversorgungssystem
Modell: OMNIVSX1500
Akustische Signale: Ja
USB Anschluss: Ja
Stecker: C14-Koppler
Ursprungsland: China
Reaktionszeit: 0 ms
Geräuschpegel: 40 dB
Ausgangsleistung: 900 W
Eingangsfrequenz: 50/60 Hz
Effizienz: 95 %
Anzahl der AC-Ausgänge: 8 AC-Ausgänge
USV-Topologie: Line-Interaktiv
Eingangs-Betriebsspannung (min): 220 V
Eingangs-Betriebsspannung (max): 240 V
Ausgangskapazität: 1.5 kVA
Ausgangs-Betriebsspannung (min): 220 V
Ausgangs-Betriebsspannung (max): 240 V
Automatische Spannungsregulierung: Ja
AC-Steckertypen: C13-Koppler
Typische Backup-Zeit bei halber Belastung: 6.5 min
Wellenform: Sine
Regulierung der Ausgangsspannung: -13 - 7 %
Stromstärke (maximal): 10 A
EMI/RFI Lautstärkefilter: Ja
Akustische Alarm-Modi: Alarm when on battery, Low battery alarm
Anzahl der Eingangs-Phasen: 1
Übertragungszeit (Line-Modus in Batterie-Modus): 6 ms
Anzahl der Ausgangs-Phasen: 1
Anstieg der Energiemenge: 312 J