Tripp Lite HT1000UPS Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Tripp Lite HT1000UPS (5 Seiten) in der Kategorie Unterbrechungsfreies Stromversorgungssystem. Dieser Bedienungsanleitung war für 29 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/5
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: HT1000UPS
Audio/Video Digital UPS - Line-Interactive UPS System with LCD Status Screen
Highlights
Automatic voltage regulation protects sensitive A/V components from
damaging power fluctuations
Reliable battery support preserves settings and recordings through blackouts
EMI/RFI line noise filtering improves component performance (fuller
audio/sharper video)
8 widely spaced AC outlets (4 UPS/surge, 4 surge-only); USB port and FREE
PowerAlert Software (Web download)
2-line 2.2 GHz cable/satellite/antenna coaxial surge protection plus single-line
tel/DSL surge protection
$100,000 Ultimate Lifetime Insurance (USA and Canada only)
Description
Tripp Lite's HT1000UPS Line-Interactive Digital UPS System offers voltage regulation, surge suppression and long-lasting battery support for
personal computers, home entertainment systems and media centers. Internal UPS circuits support entry-level PCs for up to 60 minutes or
individual VCR/DVR component for as long as 3 hours during power failures. Prevents data loss, viewing interruptions, lost recordings and loss of
component programming. Automatic Voltage Regulation (AVR) circuits regulate brownouts as low as 89 volts back to usable levels without
consuming battery power. EMI/RFI line noise filtering improves component performance, assuring fuller audio and sharper video. Includes 4
battery-supported outlets, plus 4 surge suppression-only outlets for items not requiring battery support. USB port enables optional unattended
system shutdown without data loss in the case of extended power failure. PowerAlert Software available via free download from www.tripplite.com.
HID-compliant USB interface enables integration with built-in power management and auto-shutdown features of Windows and Mac OS X. Built-in
single-line RJ-11 phone jacks provide surge protection for a modem, satellite receiver or other peripherals with a standard dialup/DSL phone
connection. Two sets of 2.2 GHz coaxial jacks protect against surges entering on CATV, satellite or broadcast antenna connections. Built-in audible
alarm and large LCD front panel voltage display indicates line power status, battery power status, battery low/replace status and voltage boost
operation. 1000VA/500W power-handling ability supports media center PCs, home entertainment systems and audio/video components including
flat-panel TVs, VCR/DVD players and PVRs (TiVo®). Offers 3 min. battery runtime with a full load of 1000VA/500W and 11 min. with a half load of
500VA/250W. $100,000 connected equipment insurance (USA and Canada Only).
Package Includes
HT1000UPS Audio/Video Digital UPS System
1 phone and 2 gold coaxial cables
Owner's manual with warranty information
Features
LCD status screen indicates input voltage, battery capacity and a variety of operating conditions. Display is rotatable for easy viewing wwith
UPS placed vertically or horizontally
Offers automatic voltage regulation, surge suppression and long-lasting battery support during blackouts
Supports entry-level PCs up to 60 min. or single VCR/DVR components for up to 3 hours during blackouts
Regulates brownouts as low as 89V back to usable levels without using battery power
4 UPS battery-supported outlets plus 4 additional surge suppression-only outlets
USB port enables unattended shutdown in the case of extended power failure
HID-compliant USB interface enables integration with built-in power management and auto-shutdown features of Windows and Mac OS X
PowerAlert Software available via free download from www.tripplite.com
Single-line phone suppression protects standard dialup/DSL phone connection
2-line 2.2 GHz coaxial surge protection for cable, satellite and antenna connections
EMI/RFI line noise filtering improves component performance, assuring fuller audio and sharper video
1000VA/500W power handling ability supports a variety of sensitive computer, home theater and other equipment
3 min. full load runtime (1000VA/500W), 11 min. half load runtime (500VA/250W)
Cabinet adapts to tower format or rackmount shelf format; 2U rackmount installation requires optional shelf, available separately
Supports battery replacement via built-in access panel
$100,000 connected equipment insurance (USA and Canada Only)
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
1000
Output Watt Capacity
(watts)
500
Nominal Output
Voltage(s) Supported
115V; 120V
Frequency compatibility 60 Hz
Output voltage
regulation (Battery
mode)
115V (+/- 5%)
Built-in UPS output
receptacles
8 5-15R outlet(s)
Surge suppression only
outlets
4 UPS outlets, 4 surge-only outlets
Output AC waveform
(AC mode)
Sine wave
Output AC waveform
(battery mode)
PWM sine wave
INPUT
Rated input current (at
maximum load)
12A
Nominal Input
Voltage(s) Supported
120V AC
UPS input connection
type
5-15P
UPS Input cord length
(ft.)
6
UPS Input cord length
(m)
1.8
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime
(minutes)
3 min. (500w)
Half load runtime
(minutes)
11 min. (250w)
DC system voltage (VDC) 12
Battery recharge rate
(included batteries)
Less than 20 hours from 10% to 90%
Battery Access Supports battery replacement via built-in access panel
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
Undervoltage correction Input voltages between 89 and 104 are boosted by 14%
LEDS ALARMS & SWITCHES
LED Indicators Front panel LCD display
Front panel LCD display Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and
replace battery status; LCD screen rotates for rack/tower viewing
Alarms Audible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert
software
Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
480
UPS AC suppression
response time
Instantaneous
UPS Dataline
suppression
1 line TEL/DSL (1 in / 1 out); Coax jacks (2 sets)
UPS Dataline
suppression details
HD-compatible 2.2GHz coaxial protection
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form factors
supported with included
accessories
Tower
Primary form factor Tower
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / inches)
12 x 3.5 x 6.5
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / cm)
30.5 x 8.9 x 16.5
Installed whole system
dimensions in
secondary form factor
(height x width x depth /
cm)
8.89 x 30.48 x 16.51


Produktspezifikationen

Marke: Tripp Lite
Kategorie: Unterbrechungsfreies Stromversorgungssystem
Modell: HT1000UPS

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tripp Lite HT1000UPS benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem Tripp Lite

Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem

Neueste Bedienungsanleitung für -Kategorien-