Qubino ZMNHBA2 power relay Bedienungsanleitung

Qubino Nicht kategorisiert ZMNHBA2 power relay

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Qubino ZMNHBA2 power relay (2 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
Qubino
The INNOVATIVE SMALLEST and
Flush 2 relays
ORDERING CODE
Z-WAVE FREQUENCY
ZMNHBA2
868,4 MHz
ZMNHBA3
921,4 MHz
ZMNHBA4
908,4 MHz
ZMNHBA5
869,0 MHz
ZMNHBA6
916,0 MHz
This Z-Wave module is used for switching on or
off two electrical devices (e.g. lights, fans, etc ...).
The module can be controlled either through
Z-Wave network or through the wall switches.
The module is designed to be mounted inside a
“ ”flush mounting box , hidden behind a traditional
wall switch.
Module measures power consumption of two
electrical devices and supports connection of
digital temperature sensor. It is designed to act
as repeater in order to improve range and
stability of Z-wave network.
Supported switches
Module supports switches (push mono-stable
button) and switches. The module is bi-stable
factory set to operate with bi-stable switches.
Installation
Before the installation disconnect power
supply.
Connect the module according to electrical
diagram.
Locate the antenna far from metal elements
(as far as possible).
Do not shorten the antenna.
Danger of electrocution!
Module installation requires a great degree of
skill and may be performed only by a qualified
and licensed electrician.
Even when the module is turned off, voltage
may be present on its terminals. Any works
on configuration changes related to
connection mode or load must be always
performed by disconnected power supply
(disable the fuse).
Note!
Do not connect the module to loads exceeding
recommended values. Connect the module only
in accordance to the below diagrams. Improper
connections may be dangerous.
Package contents
Flush 2 relays
Electrical diagram 230VAC
Notes for the diagram:
Electrical diagram 24VDC
Notes for the diagram:
Durability of the device depends on applied load.
For resistive load (light bulbs, etc.) and 4A
current consumption of each individual electrical
device, the durability exceeds 70.000 switches of
each individual electrical device.
Module Inclusion (Adding to Z-Wave
network)
Connect module to power supply (with
temperature sensor connected - if
purchased),
bring module within maximum 1 meter (3
feet) of the main controller,
enable add/remove mode on main controller,
auto-inclusion (30 minutes after connected
to power supply) or
press service button for more than 2 S
second or
press push button three times within 3s I1
(3 times change switch state within 3
seconds)
Module Exclusion/Reset (Removing
from Z-Wave network)
Connect module to power supply
bring module within maximum 1 meter (3
feet) of the main controller,
enable add/remove mode on main controller,
press service button for more than 6 S
second or
press push button five times within 3s (5 I1
times change switch state within 3 seconds)
in the first 60 seconds after the module is
connected to the power supply.
By this function all parameters of the module are
set to default values and own ID is deleted.
If service button S is pressed more than 2 and
less than 6second module is excluded, but
configuration parameters are not set to default
values
Association
Association enables Flush 2 relays module to
transfer commands inside Z-Wave network
directly (without main controller) to other Z-Wave
modules.
Associated Groups:
Group 1: basic on/off (triggered at change of the
output Q1 state and reflecting its state) up to 16
nodes.
Group 2: basic on/off (triggered at change of the
output Q2 state and reflecting its state) up to 16
nodes.
Group 3: default reporting group (reserved for the
main controller).
Configuration parameters
Parameter no. Input 1 switch type 1
Available configuration parameters (data type is
1 Byte DEC):
default value 1
mono-stable switch type (push button) 0
-stable switch type 1 bi
Parameter no. 2 Input 2 switch type
Available configuration parameters (data type is
1 Byte DEC):
default value 1
mono-stable switch type (push button) 0
-stable switch type 1 bi
Parameter no. 10 - Activate / deactivate
functions ALL ON/ALL OFF
Available configuration parameters (data type is
1 Byte DEC):
default value 255
255 - ALL ON active, ALL OFF active.
- ALL ON is not active ALL OFF is not 0
active
- ALL ON is not active ALL OFF active 1
- ALL ON active ALL OFF is not active 2
On/Off module responds to commands ALL ON /
ALL OFF that may be sent by the main controller
or by other controller belonging to the system.
Parameter no. 11 - Automatic turning Off relay
Q1 after set time
Available configuration parameters (data type is
2 Byte DEC):
Default value 0
- Auto OFF disabled 0
1- 65535 = 10mseconds 655,35 seconds.
Auto OFF enabled, with define time, step is
10mseconds.
Parameter no. 12 - Automatic turning Off relay
Q2 after set time
Available configuration parameters (data type is
2 Byte DEC):
Default value 0
- Auto OFF disabled 0
1- 65535 = 10mseconds 655,35 seconds.
Auto OFF enabled, with define time, step is
10mseconds.
Parameter no. 30 - Saving the state of the
relays Q1 and Q2 after a power failure
Available configuration parameters (data type is
1 Byte DEC):
default value 0
Flush 2 relays module saves its state 0
before power failure (it returns to the last
position saved before a power failure)
- Flush 2 relays module does not save the 1
state after a er failure, it returns to "off" pow
position.
Parameter no. 40 Power reporting in Watts
on power change for Q1
Set value means percentage, set value from 0
N
+VDC
L
-VDC
Q1
Output for electrical device no. 1
Q2
Output for electrical device no. 2
I2
Input for switch to control electrical
device no.2
I1
Input for switch to control electrical
device no.1
TS
Terminal for digital temperature sensor
(only for Flush 2 relays module
compatible digital temperature sensor,
which must be ordered separately).
N
Neutral lead
L
Live lead
Q1
Output for electrical device no. 1
Q2
Output for electrical device no. 2
I2
Input for switch to control electrical
device no.2
I1
Input for switch to control electrical
device no.1
TS
Terminal for digital temperature sensor
(only for Flush 2 relays module
compatible digital temperature sensor,
which must be ordered separately).
S
Service button (used to
add or remove module
from the Z-Wave
network).
100 = 0% - 100% Available configuration .
parameters (data type is 1 Byte DEC):
default value 1
Reporting Disabled 0
100 = 1% - 100% Reporting enabled. 1
Power report is send (push) only when
actual power in Watts in real time changes
for more than set percentage comparing to
previous actual power in Watts, step is 1%.
NOTE: if power changed is less than 1W, the
report is no send (pushed), independent of t
percentage set.
Parameter no. 41 Power reporting in Watts
on power change for Q2
Set value means percentage, set value from 0
100 = 0% - 100% Available configuration .
parameters (data type is 1 Byte DEC):
default value 1
Reporting Disabled 0
100 = 1% - 100% Reporting enabled. 1
Power report is send (push) only when
actual power in Watts in real time changes
for more than set percentage comparing to
previous actual power in Watts, step is 1%.
NOTE: if power changed is less than 1W, the
report is not send (pushed), independent of
percentage set.
Parameter no. 42 Power reporting in Watts
by time interval for Q1
Set value means time interval (0 65535) in
seconds, when power report is send. Available
configuration parameters (data type is 2 Byte
DEC):
default value 300 (power report in Watts is
send each 300s)
Reporting Disabled 0
65535 = 1 second 65535 seconds. 1 – –
Reporting enabled, Power report is send
with time interval set by entered value.
Parameter no. 43 Power reporting in Watts
by time interval for Q2
Set value means time interval (0 65535) in
seconds, when power report is send. Available
configuration parameters (data type is 2 Byte
DEC):
default value 300 (power report in Watts is
send each 300s)
Reporting Disabled 0
65535 = 1 second 65535 seconds. 1 – –
Reporting enabled, Power report is send
with time interval set by entered value.
Technical Specifications
110 - 230 VAC ±10%
50/60Hz, 24-30VDC
2 X 4A / 230VAC
2 X 4A / 30VDC
2 X 920W (230VAC)
2 X W (24VDC) 96
P=0-200W, - +/ 2W
P>200W, - +/ 3%
- + 50 ~ 125°C
-10 ~ + 40°C
up to 30 m indoors
(depending on
building materials)
41,8x36,8x16,9mm
(79x x22) 52
28g (34g)
0,4W
Ø ≥ 60mm or 2M
Relay (2x)
*In case of load other than resistive, pay attention
to the value of cos φ and if necessary apply load
lower than the rated load. Max current for cos
φ=0,4 is 2A at 250VAC 3A at 24VDC.,
Z-Wave Device Class:
BASIC_TYPE_ROUTING_SLAVE
GENERIC_TYPE_SWITCH_BINARY
SPECIFIC_TYPE_POWER_SWITCH_BINARY
Z-Wave Supported Command Classes:
COMMAND_CLASS_BASIC
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_METER_V3
COMMAND_CLASS_SENSOR_MULTILEVEL_ V3
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_VERSION
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC
Endpoint 1 (I1):
Device Class:
GENERIC_TYPE_SWITCH_BINARY
SPECIFIC_TYPE_POWER_SWITCH_BINARY
Command Classes:
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_METER_V3
Endpoint 2 (I2):
Device Class:
GENERIC_TYPE_SWITCH_BINARY
SPECIFIC_TYPE_POWER_SWITCH_BINARY
Command Classes:
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_METER_V3
This product can be included and operated in any
Z-Wave network with other Z-Wave certified
devices from any other manufacturers. All
constantly powered nodes in the same network
will act as repeaters regardless of the vendor in
order to increase reliability of the network.
Important disclaimer
Z-Wave wireless communication is inherently not
always 100% reliable, and as such, this product
should not be used in situations in which life
and/or valuables are solely dependent on its
function.
Warning!
Do not dispose of electrical appliances as
unsorted municipal waste, use separate
collection facilities.
Contact your local government for information
regarding the collection systems available. If
electrical appliances are disposed of in landfills
or dumps, hazardous substances can leak into
the groundwater and get into the food chain,
damaging your health and well-being. When
replacing old appliances with new once, the
retailer is legally obligated to take back your old
appliance for disposal at least for free of charge.
This user manual is subject to change and
improvement without notice
Qubino
Goap d.o.o. Nova Gorica
Ulica Klementa Juga 007
5250 Solkan
Slovenia
E-mail: info@qubino.com
Tel: +386 5 335 95 00
Web: www.qubino.com
Date: .2.2015 20
Document: Qubino_Flush 2
relays user maual_V6 _eng .4


Produktspezifikationen

Marke: Qubino
Kategorie: Nicht kategorisiert
Modell: ZMNHBA2 power relay
Gewicht: 28 g
Produktfarbe: Blau
AC Eingangsspannung: 110-230 V
AC Eingangsfrequenz: 50 - 60 Hz
Abmessungen (BxTxH): 41.8 x 15.4 x 36.8 mm
Anzahl der Pole: 2
Reihe von Modulen: 1

Brauchst du Hilfe?

Wenn Sie Hilfe mit Qubino ZMNHBA2 power relay benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Qubino

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-