Jøtul F 50 TL Rangeley Bedienungsanleitung

Jøtul kachel F 50 TL Rangeley

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Jøtul F 50 TL Rangeley (28 Seiten) in der Kategorie kachel. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/28
Jøtul F 50 TL Rangeley
tul F 50 TL Rangeley
Wood Stove
Installation and Operating Instructions
for the U.S. and Canada
The Jøtul is listed to burn solid wood F 50 TL
only. Do not burn any other fuels.
Read this entire manual before you install
and use this appliance.
Save these instructions for future reference
and make them available to anyone using or
servicing the fireplace insert.
This wood heater requires periodic inspection
and repair for proper operation. See this
manual for specific maintenance information.
It is against federal regulations to operate
this wood heater in a manner inconsistent
with the operating instructions in this
owner’s manual.
2
139262 Rev_S F 50 TL Rangeley 1/20
Table of Contents
Standards / Codes ................................................... 3
Accessories ...................................................................................3
Safety Notices ............................................................................ 4
1.0 Installation
1.1. Assembly Before Installation 5 ..............................................
1.2 Flue Collar Installation 6 ..........................................................
1.3 Flue Collar Heat Shield 6 ..........................................................
1.4 Bottom Heat Shield Installation......................................... 6
1.5 Leg Leveller Installation 6 ........................................................
1.6 Chimney Connector 6 ...............................................................
2.0 Chimney Requirements
2.1 Masonry Chimneys 7 ...............................................................
2.2 Prefabricated Chimneys 8 .......................................................
2.3 Chimney Height 8 .....................................................................
2.4 Wall Pass-Throughs 8 ...............................................................
3.0 Connecting to the Chimney
3.1 Masonry Chimneys 9 ...............................................................
3.2 Hearthmount into a Masonry Fireplace 9 ...........................
3.3 Prefabricated Chimneys 10 .......................................................
3.4 Mobile Home Requirements 10 ..............................................
4.0 Clearances to Combustibles
4.1 Floor Protection 11 ......................................................................
4.2 Clearances to Walls and Ceilings 11 ........................................
4.3 Using Shields to Reduce Clearances 11 ..................................
4.4 Alcove Installation 12 .................................................................
4.5 Fireplace Clearances, Mantel and Trim ................................ 12
4.6 Clearance Diagrams 13 ..............................................................
5.0 Operation
5.1 Combustion Efficiency 14 ..........................................................
5.2 CO Emissions 14 ...........................................................................
5.3 Wood Fuel and Performance 14 ...............................................
5.4 F 50 TL Rangeley Functionality............................................15
5.5 Air Control 15 ................................................................................
5.6 Top Loading 15 .............................................................................
5.7 Controlling the Fire 16 ................................................................
5.8 Break-in Procedure 16 ................................................................
5.9 Starting and Maintaining a Fire 16 ........................................
5-10 Adding Fuel 17 .............................................................................
5.11 Open Door Fire-viewing 17 ......................................................
5.12 Creosote Formation 17 ..............................................................
5.13 Ash Removal 17 ...........................................................................
6.0 Maintenance
6.1 Glass Care 18 .................................................................................
6.2 General Care 18 ............................................................................
6.3 Glass Removal or Replacement 18 ..........................................
6.4 Gaskets .....................................................................................19
6.5 Gasket Replacement 19 .............................................................
6.6 Chimney System 19 ....................................................................
7.0 Appendix
7.1 Blower Installation 20 ................................................................
7.2 Outside Air Kit Installation 22 .................................................
7.3 Mobile Home Floor Bracket 23 ................................................
8.0 Illustrated Part List ........................................................... 24
9.0 Warranty Statement 26 ....................................................
Installation and Operation
Instructions for USA/Canada
Safety Notice: If this solid fuel room heater is not
properly installed, a house fire may result. For your
safety, follow the installation directions. Contact
local building or fire officials about restrictions
and installation inspection requirements in your
area. Save these instructions for future reference.
3
139262 Rev_S F 50 TL Rangeley 1/20
Jøtul F 50 TL Accessories
Spark Screen #157232
Enjoy the warmth of open door fire-viewing with use of
this custom fit spark screen.
Stove-Top Thermometer #5002
We recommend the use of a magnetic stove-top ther-
mometer to monitor the surface temperature of the
stove.
The optimum surface temperature range for the most
efficient performance is between 400
0 F - 7000 F
(2050 C - 3160 C).
Outside Air Kit #157320
This kit includes a plenum assembly which attaches to
the stove bottom. It permits connection of duct work
from an outside source directly to the air intake of the
stove. A direct outside air connection is required for
mobile home installations.
Mobile Home Floor Bracket Kit #157321
This kit includes two brackets used to fulfill the mobile
home requirement that the stove be secured directly to
the floor.
Blower Kit #156431
This kit includes components for mounting a thermo-
statically controlled 120 cfm blower to the back of the
stove to enhance heat convection into the living area.
Standards
The Jøtul F TL Rangeley wood stove has been tested 50
and listed to:
U.S: ANSI/UL 1482-2011 and ANSI/UL 737-2011
Canada: CAN/ULC-S627- and ULC-S00 628-93
Certified Safety Tests conducted
and listed by:
ITS, Intertek Testing Services
Middleton, WI
Manufactured by:
Jøtul North America
55 Hutcherson Drive
Gorham, Maine 04038-2644
WARNING !
THIS WOOD HEATER HAS A MANUFACTURER-
SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL
REGULATIONS TO ALTER THIS SETTING
OR OTHERWISE OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
This heater meets the 2015 U.S.
Environmental Protection Agency’s
emission limits for wood heaters
manufactured after May 15, 2015.
This appliance may not be sold after
May 15, 2020.
Check Building Codes
When installing, operating and maintaining your
Jøtul F TL Rangeley woodstove, follow the guidelines 50
presented in these instructions, and make them
available to anyone using or servicing the stove.
Your city, town, county or province may require a
building permit to install a solid fuel burning appliance.
In the U.S., the National Fire Protection Association’s
Code, NFPA 211, Standards for Chimneys, Fireplaces, Vents
and Solid Fuel Burning Appliances, or similar regulations,
may apply to the installation of a solid fuel burning
appliance in your area.
In Canada, the guideline is established by the CSA
Standard, CAN/CSA-B365-M93, Installation Code for
Solid-Fuel-Burning Appliances and Equipment.
Always consult your local building inspector or authority
having jurisdiction to determine what regulations apply
in your area. Your local officials have final authority in
determining if a proposed installation is acceptable. Any
requirement by the local authority having jurisdiction
that is not specifically addressed in this manual, defaults
to NFPA 211, and local codes in the U.S. or in Canada, CAN/
CSA-B365-M and local codes.
The Jøtul F TL Rangeley is approved for use in mobile 50
homes. Install in accordance with 24 CFR, Part 3280
(HUD).

Produktspezifikationen

Marke: Jøtul
Kategorie: kachel
Modell: F 50 TL Rangeley

Brauchst du Hilfe?

Wenn Sie Hilfe mit Jøtul F 50 TL Rangeley benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung kachel Jøtul

Bedienungsanleitung kachel

Neueste Bedienungsanleitung für -Kategorien-