Valcom Page Zone Extender VIP-801 Bedienungsanleitung

Valcom Nicht kategorisiert Page Zone Extender VIP-801

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Valcom Page Zone Extender VIP-801 (3 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
1 947995
ISSUE 6
VIP-801
ENHANCED NETWORK AUDIO PORT
INTRODUCTION
The VIP-801 Enhanced Network Audio Port
enables voice access to a single zone of one-way
paging over an IP network, allowing page zones
to be extended anywhere network connectivity is
available. The VIP-801 can be programmed as a
SIP (Session Initiation Protocol) device for
connectivity to virtually any Voice over IP (VoIP)
telephone system.
SPECIFICATIONS
Features
1 Audio Output or Input
2 Form C Relays
1 Contact Closure Input
1 SIP identity for registering to a VoIP telephone
system
RJ-45 jack for network connection
Front panel activity LED
Provides audio for up to 40 Valcom one-way
amplified speaker assemblies
AUX audio input via RCA jack
Contact closure or VOX operation of audio input
Removable screw terminal connectors provided
for audio and relay interface
AUX input music mutes during page
Output control contact closure provided during
paging output
Compatible with 25 or 70 Volt amplifiers
2.5mm jack for optional DC power
Power over Ethernet (PoE) 802.3af compatible
Dimensions/Weight
1.38 H x 6.13" W x 5.25" D
(3.50cm H x 15.6cm W x 13.33cm D)
Weight: 1.25 lbs. (0.57 kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm nominal
Voice Switch Sensitivity: -21dBm
AUX Input Impedance: 8 to 600 Ohms
AUX Input Level: -10dBm nominal
Output Impedance: 50 Ohms
Output Level: - 10dBm nominal
Relay Current: 1 Amp @ 24VDC
Nominal Power Requirements
Via rear panel barrel connector:
Voltage: 24VDC
Current: 325mA
Via 802.3af PoE Ethernet Switch:
802.3af: Class 3
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
Packing List
Qty Item
1 VIP-801
1 VSP Document
2 Mounting Brackets W/ Hardware
4 Rubber Pads
2 947995
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service pe rsonnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present with in this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
INSTALLATION
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when
the equipment is operated in a commercial
environment. This equipment generates, uses
and can radiate radio frequency energy and if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area
may cause harmful interference in which case
the user will be required to correct the
interference at his own expense.
Precautionary Designations
Mounting
The VIP-801 is designed for wall or table mounting.
Table: Provided with the VIP-801 are four rubber
pads. Peel the pads from their carrier backing
and place at the four corners of the bottom of the
unit.
Wall: Using the brackets and screws provided,
secure the VIP-801 to the wall.
Power Connections
The preferred method of powering a VIP-801 is via
a power over Ethernet switch meeting the 802.3af
specification.
If the rear panel barrel connector is used for power,
the preferred power supply is a Valcom VIP-324D.
Make all required signal connections before
applying power to the unit. If powering via 802.3af,
make sure all signal connections via the back panel
are made then connect the VIP-801 to the Ethernet
switch.
If power is supplied via the barrel connector, make
sure all signal connections are secure. Attach the
unit to the network via the front panel RJ-45
Ethernet connector. Apply power by plugging the
power supply into the VIP-801 via the barrel
connector on the rear of the VIP-801.
Network Connection
The VIP-801 has one RJ-45 network connector on
the front panel. Use a standard Ethernet patch
cable to connect the VIP-801 to an Ethernet switch.
Signal Connections
The VIP-801 has 4 signal connectors on the rear
panel:
RCA jack for AUX audio input
2 Pin screw terminal for audio output
6 Pin screw terminal for relay connections
4 Pin screw terminal for audio input and contact
closure input
AUX Input: Local audio may be input via the
rear panel RCA jack. Nominal input impedance
is 600 Ohms. Connect any compatible audio
source using an RCA patch cable. Audio
supplied through the rear panel RCA jack is
transformer coupled to Audio Out when Audio Out
is idle. This is typically used for background music.
Audio Out: Typically connects to Self Amplified
Speakers or into an amplifier. AUX Input audio
mutes when Audio Out is receiving page audio.
Audio Input/Contact Closure: The audio input
and contact closure share a four pin terminal
connection. Neither input is polarity sensitive.
The contact closure is on the right two terminals
labeled "CC". The audio input is on the left two
terminals labeled "AUDIO".
3 947995
K1 K2 INPUTSAUDIOAUX
OUTIN AUDIO CC
+24V DC
N.C.
N.O.
N.C.
N.O.
COM
COM
STATUS
LINK
ACT
Relay Channels: Access to the two form C relays
is provided via a six pin screw terminal block. The
relays are labeled K1 and K2. Each relay is
brought out on three terminals. The common
contact is the middle terminal with the normally
closed contact on the right and the normally open
contact on the left. Relay contacts are rated for 1A
@ 24VDC.
Rear View
Status Indicator Lights
The VIP-801 has 3 status indication lights on the
front panel:
STATUS: Flashes during normal operation and
solid during system startup.
LINK: Indicates a 100 Mbit Ethernet connection
when illuminated. A non-illuminated LINK LED
indicates a 10 Mbit connection or no network
connection.
ACT: Indicator flashes to indicate network activity.
Front View
Setup
Information specific to your application will need
to be programmed into the VIP-801 using a
computer. The PC used for programming should
be connected to the same subnet as the VIP-801.
Setup will be done using the IP Solutions Setup
Tool. Download the latest version of the free IP
Solutions Setup Tool from the Valcom web site at
www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute
a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the
factory. Call (540) 563-2000 and press 1 for
Technical Support or via email at
support@valcom.com.
When requesting assistance, you should include all
available information. General information and
troubleshooting procedures are available on the
Valcom website at www.valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of
normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or refund
of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts
and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation,
maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the
specific Product covered by the warranty.
Disclaimer. Except for the Limited Warranty provided herein, the product is provided “as-is” without any warranty of any kind whatsoever including, without
limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road Roanoke, VA 24019-5056
Phone: (540) 563-2000 FAX: (540) 362-9800


Produktspezifikationen

Marke: Valcom
Kategorie: Nicht kategorisiert
Modell: Page Zone Extender VIP-801

Brauchst du Hilfe?

Wenn Sie Hilfe mit Valcom Page Zone Extender VIP-801 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Valcom

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-