Sani-Lav 725 Bedienungsanleitung
Sani-Lav
SpĆ¼lbecken
725
Lesen Sie kostenlos die š deutsche Bedienungsanleitung fĆ¼r Sani-Lav 725 (7 Seiten) in der Kategorie SpĆ¼lbecken. Dieser Bedienungsanleitung war fĆ¼r 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/7
1
H A N D S - F R E E F L O O R M O U N T S I N K
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 372 Low-Lead
Operating Manual for Hands-Free Floor Mount Stainless Steel Sink
Models 725 and 725-0.5
of Domestic and Foreign Parts
H A N D S - F R E E F L O O R M O U N T S I N K 2
C O L U M B I A S P E C I F I C AT I O N S
800.626.2117 columbiasinks.com info@columbiasinks.com
Ā©2021 Columbia Products
Installation Instructions
Step 1
1. Attach upper and lower leg support brackets to legs with hardware (provided).
2. Place wash station sink on leg assembly and secure with hardware (provided).
3. Establish sink location.
4. Mark the floor where the four holes are at the base as shown in illustration A.
5. Drill holes as required for mounting hardware. (Hardware not included).
Step 2
1. Install spout assembly to the sink.
2. Install elbow fitting (provided) to the spout assembly.
3. Connect one side of the supply line (provided) to the spout assembly.
4. Install strainer assembly.
Step 3
1. Install elbow fitting to valve.
2. Install foot pedal valves under the leg assembly cross bar if not mounted already.
3. Attach connecting tube from the spout to the foot pedal valve.
Step 4
1. Secure wash station to the floor.
2. Connect waste line to strainer assembly.
3. Connect water supplies (hot and cold) to valves.
Step 5
1. Remove aerator from the spout assembly and flush water line by pressing pedal for
30 seconds.
2. Check connections for leaks. Replace aerator onto the spout assembly.
3. Seal gap between bowl and leg assembly as shown in illustration B.
4. When mounting against wall, we recommend sealing top of backsplash to wall as shown in
illustration C.
Parts List
(1) Floor mount sink
(1) Leg assembly set
(6) Nuts, bolts and washers for leg assembly
(4) Nuts and washers for connecting sink to leg assembly
(1) Double foot pedal valve
(2) Valve mounting nuts
(1) Swivel gooseneck spout with aerator
(1) Connecting tube for valve to spout connection
(2) Fittings, brass, 0.375ā male compression and 0.375ā male NPT
(1) Strainer assembly with basket
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certiīed under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Go to for more information on replacement parts and installation videos.columbiasinks.com
Illustration A
Illustration B
Illustration C
H A N D S - F R E E F L O O R M O U N T S I N K 3
C O L U M B I A S P E C I F I C AT I O N S
800.626.2117 columbiasinks.com info@columbiasinks.com
Ā©2021 Columbia Products
Valve Repair Instructions
Note: Valves are designed to be repaired without having to be disconnected from mount or plumbing.
1. Turn off water source. Do not remove valve from sink.
2. Remove pedal assembly using a 15/16ā open end wrench or socket wrench. As shown in
illustration A.
3. Using a 1ā deep socket wrench remove insert assembly parts as show in illustration B.
4. Replace with new repair kit as shown on illustration C.
5. Reinstall pedal assembly and turn water source on.
Trouble Shooting Guide
Problem Possible Cause To Diagnose Remedy
Water drips from spout
or valve stem assembly.
Flat washer on the
stem/plunger is worn.
To determine if the leak source is from the hot or cold side shut
cold water source off. See if water still leaks from the spout. If
leak continues then repair hot side if not repair cold side.
We recommend installing valve repair
kit.
Water leaks from the
front of the valve.
O-Rings on the
plunger are worn out.
Visually determine whether the cold or hot side is leaking. We recommend replacing threaded
insert, plunger assembly & spring.
See illustrations below.
Illustration A
Illustration B
Illustration C
Produktspezifikationen
Marke: | Sani-Lav |
Kategorie: | SpĆ¼lbecken |
Modell: | 725 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Sani-Lav 725 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung SpĆ¼lbecken Sani-Lav
21 August 2024
6 Mai 2024
1 Mai 2024
1 April 2024
13 MƤrz 2024
11 MƤrz 2024
5 MƤrz 2024
18 Februar 2024
6 Februar 2024
28 Januar 2024
Bedienungsanleitung SpĆ¼lbecken
- SpĆ¼lbecken Concept
- SpĆ¼lbecken Teka
- SpĆ¼lbecken Smeg
- SpĆ¼lbecken Caple
- SpĆ¼lbecken Kernau
- SpĆ¼lbecken Saro
- SpĆ¼lbecken Foster
- SpĆ¼lbecken Leisure
- SpĆ¼lbecken Gustavsberg
- SpĆ¼lbecken CDA
- SpĆ¼lbecken Schock
- SpĆ¼lbecken Rangemaster
- SpĆ¼lbecken BLANCO
- SpĆ¼lbecken Elkay
- SpĆ¼lbecken Deante
- SpĆ¼lbecken Roca
- SpĆ¼lbecken Artusi
- SpĆ¼lbecken Advance Tabco
- SpĆ¼lbecken Cookology
- SpĆ¼lbecken Tot Mate
- SpĆ¼lbecken Eagle Group
- SpĆ¼lbecken Kuchinox
- SpĆ¼lbecken Oliveri
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
18 August 2024
17 August 2024
10 August 2024
21 Juni 2024
21 Juni 2024
21 Juni 2024
13 Juni 2024
13 Juni 2024
13 Juni 2024
13 Juni 2024