Instruction Manual
22mm in-line Magnetic Filter
Model: MD22S
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right
to change specification, design and materials of products listed in this brochure without prior
notice.
Head Office:
SALUS Controls
Units 8-10, Northfield Business
Park, Forge Way, Parkgate
Rotherham, S60 1SD
Email: sales@salus-tech.com
www.salus-controls.com
Issued: July 2021
V007
The following instructions are designed to help the engineer to install
and maintain the Magnetic Filter safely and eciently and should be
followed and adhered to at all times. Make sure there is a water-lling
pipeline behind the lter. During maintenance, check whether the lid
seals are worn or damaged. The best practice is to replace the lid seal at
each repair.
The Magnetic Filter is specially designed for central heating systems. It can
remove almost all the harmful black suspended iron oxide particles accumulated
in the central heating system and protect the complete central heating system.
The lter can be installed in a variety of ways, for example: be installed at any
location on the main pipeline. However, it is recommended to be installed
after the last radiator and before the boiler on the primary return pipework for
maximum protection and eciency.
Note: It is important to have adequate access for maintenance and
servicing when determining a suitable installation location.
1 Air vent valve
2 Magnet bar
3 Drain valve
4 Inlet valve
5 Outlet valve
Open vented system
Figure 2
Combination/Sealed system
Figure 1
1. INTRODUCTION
3. STRUCTURE INTRODUCTION
2. MOUNTING RECOMMENDATIONS
Recommended installation location
RETURN
Boiler
RETURN
Boiler
Pump
Header Tank
Vent
Pipe
2
1
3
4
5
4. INSTALLATION METHOD
5. MAINTENANCE AND SERVICING
Instruction manual of magnetic lter
1. Cut and remove the section of the pipe according to the product installation length;
2. Install the valves onto the pipework, hand tighten only at rst, then tighten securely the valve to the pipe;
3. Install the lter housing and tighten it;
4. Adjust the Angle and secure the lter;
5. Make sure the valves are open, allow the system to ll, open, and vent the lter through the air vent valve,
close when complete.
1. Close both the isolation valves;
2. Open the drain valve, place a bucket or similar receptacle below ready to collect the debris. Take out the
magnetic bar and store in a safe place;
3. Open the inlet valve to ush out the debris, once all the debris has been removed introduce a suitable
chemical inhibitor into the system, we recommend Salus LX1 inhibitor, ret the magnetic bar;
4. Open the inlet and outlet valve, vent the lter through the air vent valve close when complete.
Check for any leaks;
5. Complete any relevant documentation.
IE: Dates and inhibitor used.
1. The magnetic lter contains powerful magnets, please keep away from all electronic devices, bank cards
and other magnetic devices;
2. The Magnetic Filter contains powerful magnets and should always be used with caution especially for
devices such as pacemakers;
3. The Magnetic Filter is a pressurized device, pressure must be released prior to maintenance;
4. The Magnetic Filter device could be very hot during operation. Please be careful!
* In order to maintain grounding continuity in accordance with the current IEE regulations, appropriate grounding cables should be
installed on the pipe where necessary to bypass the product.
* Please read the product manual carefully before installation and use.
12 3 4
12 3 4
Note: Prior to carrying out any maintenance work, isolate the electrical supply to the boiler allowing
the water to cool down to a safe working temperature.
Note: It is recommended that the magnetic lter is installed and maintained by a competant and
qualied person. Any queries arising from either installation or servicing, contact SALUS Controls at
techsupport@salus-tech.com
Maximum working pressure: 6bar Maximum operating temperature: 95 °C
Flow rate: < 50 l/min Direction of ow: follow the arrow
Please note: