INSTALLATION INSTRUCTIONS
No. 59-1901-0
Warning Caution
1PARTS IDENTIFICATION
2INSTALLATION HINTS
PASSIVE INFRARED DETECTOR
PASSIVE INFRARED DETECTOR
SAVER
SAVER
1 32 Knock out
4Wire Corner mounting >>Backside mounting >>
Twist
Push Pull
SIDE VIEWTOP VIEW
N.C. N.C.
+ –
12 VDC
SP SP
ALARM TAMPER
LED
ON
(default) OFF
SENSITIVITY
LOW MID
(default) Hi
5 10 15 20 25 30 35 40ft
6
4
2
15
10
5
20ft
2 4 6 8 10 12m
4
6
0
2
0
5
10
15
20ft
5 10 15 20 25 30 35 40ft
0
2.4m 12m1086420
8ft
Power wire maximum length
( using one unit on a single wire )
AWG 22 (0.33m2)
AWG 20 (0.52mm
2)
AWG 18 (0.83mm
2)
520m (1700’)
820m (2690’)
1310m (4290’)
1130m(3700’)
1780m(5830’)
2850m(9350’)
WIRE GAUGE 12V DC 14V DC
N.C. N.C.+ –
12 VDC
SP SP
ALARM TAMPER
(1) (2) (3) (4)
(1) Power input
(2) Spare
(3) Alarm output (N.C.)
(4) Tamper (N.C.)
Detect LED ON
EN
Model
Detection method
Coverage
Detection zones
Mounting height
LED alarm indicator
Alarm period
Alarm output
Tamper switch
Sensitivity/range
Warm up period
Power input
Current draw
Dimensions
Weight
Operating temperature
Environmental humidity
RF interference
SAVER
Passive infrared
12m x 12m (40ft x 40ft) 85°wide
78 zones
1.5 to 2.4m (5 to 8ft)
Switchable ON/OFF
Approx. 2.5 sec
N.C., 24VDC 0.2A max.
N.C., Open when cover is removed.
Switchable LOW/MID/HI
Approx. 60 sec
9.5 to 16VDC
8mA (normal), 11mA (max.) at 12VDC
93.4mm x 61.4mm x 46.0mm <HxWxD>
Approx. 70 g (with bracket: 90 g)
-20°C to +50°C (-4°F to +122°F)
95% max.
No alarm 10V/m
Tamper output 24VDC 0.1A max.
Unit: mm (inch)
61.4 (2.4)
93.4 (3.7)
46 (1.8)
LONG RANGE
(OPTIONAL LENS: FL-60N)
1.5m 10
5ft
20 30 40 50 60ft
0
1.5m 5 10 15 18m
0
5ft
0 10 20 30 40 50 60ft
18m15
1050
2.4m
NOTE
3INSTALLATION
The nix sign indicates prohibition
4DETECTION ZONE
5WIRING
6
SENSITIVITY AND LED
7
WALK TEST
8DIMENSIONS
9SPECIFICATIONS
10
OPTION
SIDE VIEW
TOP VIEW
11
COMPLIANCE
This unit is designed to detect movement of an intruder and activate
an alarm control panel.
Being only a part of a complete system, we can not accept
responsibility for any damages or other consequences resulting
from an intrusion.
Lens
Cover
Terminals
Sensitivity LOW/MID/HI
LED ON/OFF
Tamper switch
Sealing sponge