INTERNAL USE ONLY: PN 24328
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2023 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069, USA / tel. 800.325.9660 / tel. 636-257-3400 / www.lowellmfg.com
Spec 1778
Model RPC-3N1 | Rev. 1-12-23 | pg. 1/3
REMOTE POWER CONTROLS can be combined with a variety of switches or sequencers for an intrinsically
safe, low voltage method of controlling AC power to equipment at remote locations. Controlling power
distribution without directly accessing equipment minimizes the potential for unauthorized access, while
simplifying activation and deactivation of equipment.
Note: RPCs require an external trigger for activation (order separately).
Ideal for Lowell switches featuring main-
tained closure (order separately):
RPSB-P Black wall plate w/rocker switch
RPSW-P White wall plate w/rocker switch
RPSW-KP White wall plate w/key switch
RPSB-R Rack panel w/rocker switch
RPSB-KR Rack panel w/key switch
Model No.
RPC-3N1
Remote Power Control
actives remote equipment external trigger required
FEATURES
CHASSIS: Steel chassis (16"L x 3"W x 2.5"H)
with black finish and mounting holes.
POWER:
Power Rating: 125VAC 60Hz 15A
Outlets: Total of eight (8) NEMA 5-15R outlets,
which include 1 unswitched duplex and 3
switched duplexes.
Attached Cord: 6 ft. cord with NEMA 5-15P plug
ACTIVATION: Activation of the three individually
controlled duplexes is via contact closure be-
tween the common terminal and the (numbered)
control terminals.
Dry Contact Closure: Connect to SPST switch,
power sequencer, or independent control sys-
tem with dry contact closure.
: Contact Coil Rating
- Voltage: 24VDC
- Current: 37.5mA
ORIGIN: Made in the U.S.A. with global components
INSTALLATION: The RPC is typically installed near
the equipment to be controlled. Low voltage cable
is run from its terminal strip to (one or more) RPS
Series control switches (or other control method).
Systems can be configured with multiple RPCs
controlled by a single "Maintained Closure"
switch.
Systems can also be congured with a single
RPC controlled by multiple "Momentary Closure"
switches and Lowell's MSM2 module (which
converts momentary closure to maintained).
COMPATIBLE DEVICES: (order separately)
SPST Switch (RPS Series): Low voltage wall-
mount or rack-mount switch:
Switch with maintained closure con-
nects directly to RPC.
Switch with momentary closure requires
Lowell conversion module MSM2
placed between the switch and RPC.
Power Sequencer (SEQ Series): A low volt-
age sequencer can be used with the RPC
for time-delayed activation and deactivation
of connected equipment. Lowell standalone
sequencers will require a switch for activation,
while Lowell rack-mount sequencers include a
switch. See product spec sheets for information.
Certied
US Steel
Made In USA
with Global
Components
A&E SPECIFICATIONS
The device for remotely controlling AC power shall be Lowell model RPC-3N1 which shall feature a steel
chassis (16" x 3" x 2.5")with black powder epoxy finish, 125VAC 60Hz 15A power rating, NEMA 5-15R
outlets (1 unswitched duplex, 3 switched duplexes), 24VDC output, and 6 ft. cord with NEMA 5-15P plug.
The unit shall require an external trigger (not included) to activate switched outlets.
INTERNAL USE ONLY: PN 24328
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2023 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069, USA / tel. 800.325.9660 / tel. 636-257-3400 / www.lowellmfg.com
Spec 1778
Model RPC-3N1 | Rev. 1-12-23 | pg. 2/3
APPLICATION 1 (Switch): Using a remote switch to control individual duplex outlets:
Typical connections are made using low-voltage three-conductor cable run from the RPC terminal strip to remotely located RPS Series switches.
Connect the three barrier strip terminals on the RPC (marked “+24v Out”, “Com and “Switch”) to corresponding terminals on the RPS Series switch
(see Lowell switches with MAINTAINED closure on pg. 1).
Lowell
RPS Series
switches with
MAINTAINED
closure
Unswitched Duplex (1)
(always on)
Switched Duplexes (3)
Equipment to be controlled plugs into three
individually switched duplexes.
Activation of these outlets is by contact closure
between the common terminal and the (numbered)
control terminals.
SERIES OVERVIEW
Model No. Chassis Outlets Input Power Rating Surge Suppression ConnectionsExternal Activation Required
RPC-15 Standalone NEMA 5-15R (2) 6' attached cord 125VAC 60Hz 15A --- Dry contact closure Terminal Strip
RPC-15-S Standalone NEMA 5-15R (2) 6' attached cord 125VAC 60Hz 15A Dry contact closure Terminal StripYes
RPC-15-SCD-RJ Standalone NEMA 5-15R (2) 6' attached cord 125VAC 60Hz 15A Dry contact closure or VT* TS or RJ45Yes
RPC-15-U Standalone IEC C13 (2) 6' detachable cord (2) 100-240VAC 50/60Hz 15A --- Dry contact closure or VT* Terminal Strip
RPC-20-CD Standalone NEMA 5-20R (2) 6' attached cord 125VAC 60Hz 20A --- Dry contact closure or VT* Terminal Strip
RPC-20-SCD Standalone NEMA 5-20R (2) 6' attached cord 125VAC 60Hz 20A Dry contact closure or VT* Terminal StripYes
RPC-20-SCD-RJ Standalone NEMA 5-20R (2) 6' attached cord 125VAC 60Hz 20A Dry contact closure or VT* TS or RJ45Yes
RPC-3N1 Standalone NEMA 5-15R (8) 6' attached cord 125VAC 60Hz 15A --- Dry contact closure Terminal Strip
RPC-4CD Rack-mount NEMA 5-15R (8) 6' attached cord 125VAC 60Hz 15A --- Dry contact closure Terminal Strip
RPC-20-HW Standalone NEMA 20A (2) 6'  exible whip 125VAC 60Hz 20A --- Dry contact closure or VT* Terminal Strip
RPC-20-SHW Standalone NEMA 20A (2) 6'  exible whip 125VAC 60Hz 20A Dry contact closure or VT* Terminal StripYes
RPC-30-SHW Standalone Twistlock 30A (1) 6'  exible whip 125VAC 60Hz 30A Dry contact closure or VT* Terminal StripYes
* VT indicates the RPC can also accept a voltage trigger provided by an independent control system.
T H I S
SPEC
INTERNAL USE ONLY: PN 24328
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2023 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069, USA / tel. 800.325.9660 / tel. 636-257-3400 / www.lowellmfg.com
Spec 1778
Model RPC-3N1 | Rev. 1-12-23 | pg. 3/3
APPLICATION 2 (Switch & Sequencer) Using a remote switch and sequencer for time-delayed activation/deactivation of duplex outlets.:
Typical connections are made using low-voltage two-conductor cable from the RPC terminal strip “Com” and “Switch” connections to corresponding
terminals on the sequencer. “Com terminals can be tied together on one conductor. Note: “+24v Out” connection on the RPC is not used in sequencer
applications.
The switch connections are made from the sequencer’s barrier strip terminals (marked “24v Out”, “Com” and “Switch”) to corresponding terminals on
the RPS Series switch (see Lowell switches with MAINTAINED closure on pg. 1).
Lowell
SEQ Series
sequencer
Lowell RPC Series
remote power control
(use if additional circuit is desired)
Unswitched Duplex (1)
(always on)
Lowell SEQ Series sequencer
can be plugged into the
unswitched outlet.
Switched Duplexes (3)
Equipment to be controlled plugs into the three
individually switched duplexes.
Lowell
RPS Series
switch with
MAINTAINED
closure
Lowell #SEQ-4


Produktspezifikationen

Marke: Lowell
Kategorie: Nicht kategorisiert
Modell: RPC-3N1
Breite: 406.4 mm
Tiefe: 63.5 mm
Produktfarbe: Schwarz
Höhe: 76.2 mm
Eingangsspannung: 125 V
Eingangsfrequenz: 60 Hz
Anzahl der AC-Ausgänge: 8 AC-Ausgänge
Stromstärke (maximal): 15 A
Ausgangsleistung (max.): - W