Lowell ACSP-1502-VTE Bedienungsanleitung

Lowell Nicht kategorisiert ACSP-1502-VTE

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Lowell ACSP-1502-VTE (3 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
INTERNAL USE ONLY: PN 24236
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1740
Model ACSP-1502-RPC Rev. 06-22-21 | pg. 1/3
Lowell’s Advanced Surge Suppression provides multiple layers of protection for
equipment on a single circuit. With TCR technology (Triple Clamping Redundancy),
these advanced devices can protect sensitive equipment from harmful power surges
and spikes up to 72,000A, when fully active.
FEATURES
LED Status Indicators (3): Each LED lights when protection is active
for its associated stage (1, 2, or 3). An LED will not light if its associated
stage is not functioning (alerting user to repair/replace the unit).
No Ground Contamination: Suppresses line to neutral with no ground wire con-
tamination.
1.75” x 6 x 9”Low-prole Chassis:
Convenient Access: Patented* outlet plate can be rotated 90˚ for front or side
access to outlets, making it easier to accommodate unwieldy power cords.
Mounting Aids: Universal mounting brackets mount the SPD to a wall, under a
counter, or inside a rack.
Approvals: ETL Listed (conforms to UL1449-4). ANSI C62.41 Compliant.
Warranty: 10 year limited factory warranty.**
Model ACSP-1502-RPC:
RPC Remote Power Control: This unit can be controlled by a low-
voltage sequencer, switch or control system that provides a maintained
dry contact closure (order separately).
Two (2) NEMA 5-15R outlets
– 6 ft. cord with NEMA 5-15P plug
A&E SPECIFICATIONS
The 15A single-circuit surge protector shall be Lowell model ACSP-1502-RPC with
two single outlets. It shall protect the line to neutral without ground wire contamina-
tion. It shall be capable of protecting electronic equipment from transient voltages,
spikes and surges up to 72,000A and have a response time of less than 5 nano-
seconds. It shall include mounting brackets and two 15A outlets mounted on a plate
that can be rotated 90º for front or side access. It shall include LED status indicators.
It shall include remote power control capability (by low-voltage sequencer, switch or
control system that provides a maintained dry contact closure, not included). It shall
be ETL Listed and conform to UL1449-4 and ANSI C62.41
Advanced Surge Suppression ACSP-1502-RPC
ACSP SERIES SUMMARY
VTE Over/Under RPC Remote Power Limited
Model No. Amperage Outlets Termination Voltage Protection Control Circuittry Warranty
ACSP-1502-VTE 15A (2) NEMA 5-15R 6' detachable cord Yes --- 10 years
ACSP-2002-VTE 20A (2) NEMA 5-20R 6' cord Yes --- 10 years
ACSP-1502-RPC 15A (2) NEMA 5-15R 6' detachable cord --- Yes 10 years
ACSP-2002-RPC 20A (2) NEMA 5-20R 6' cord --- Yes 10 years
ACSP-2002-RPC-HW 20A (2) NEMA 5-20R 6' flexible conduit --- Yes 10 years
* U.S. Patent No. D535178S
** 10 year warranty limited to repair or replacement of unit at manufacturer’s option (original purchaser only).
Remot e
Power Control S
Normal
Test
ON
Sw
Com
V+
MADE IN U.S.A.
WITH GLOBAL
COMPONENTS
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1740
Model ACSP-1502-RPC Rev. 06-22-21 | pg. 2/3
Remove screws from plate
(2 front, 2 top).
Pull plate out from chassis.
Rotate plate so outlets are
on top; reinstall screws.
MECHANICAL SPECIFICATIONS:
Dimensions 9"W x 1.75"H x 6"D ...........................
Weight 5 lbs. ..................................
Input Connections Detachable IEC cord with NEMA 5-15P plug ..................
Output Connections................ (2) single 15A receptacles mounted on 90˚ rotatable plate
Chassis Steel with black powder epoxy nish .................................
Mounting (2) brackets ...............................
PERFORMANCE SPECIFICATIONS:
Operating Voltage/Current ...... 120VAC / 15A, 60Hz
Maximum Surge Current 72,000A (exceeds UL1449-4 6000V, 3000A) ........
Initial Clamping Voltage .......... 205V, UL rating 400V
Endurance IEEE C62.41-1991, B3 (C1), Pulses (lifetime): 1kv≥1,000,000; 3kv≥100,000; 6kv≥5000 .............................
Transient Noise Reduction 29dB@100kHz, 70dB@1MHz ......
Response Time ...................... Less than 5 nanoseconds
Operating Temperature ........... 25˚C (77˚F) nominal
Protection Mode Line to neutral, zero ground leakage ....................
UL1449-2 Adjunct Results ...... 1000 surges, 6000 volts, 3000A, C1, and B3 waveforms (IEEE C62.41), NO FAILURES
Federal GSA specs (1996) Grade A, Class 1, Mode 1 ......
Diagnostic LEDs (surge)** One green LED for each stage. All stages active when all lit. .......
Applicable Standards Conforms to UL1449-4, IEEE standard 587-80 A & B, IEEE standard C62.41-1991, IEC .............
1000-4-5-1995 (IEC 801-5).
Safety Agency Approvals......... ETL Listed US and Canada
Surface-mount with brackets
exposed.
Surface-mount with brackets
concealed behind unit.
Mount inside rack to the rail
supports or 10-32 tapped rail.
ACCESSIBLE OUTLETS: ROTATING THE OUTLET PLATE.
MOUNTING BRACKETS:
** TCR surge suppression technology provides the assurance of Grade A, Class 1, Mode 1 endurance and performance with visual diagnos-
tic LEDs. Three stage SPD (surge protective device) has a green LED indicator for each stage to show on-line status. If one stage goes
off-line, remaining stages still provide protection at the same clamping level. In the unlikely event that one or more stages goes off-line,
contact Lowell for repair or replacement under the unit’s 10 year warranty.
INTERNAL USE ONLY: PN 24223
INTERNAL USE ONLY: PN 24236
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1740
Model ACSP-1502-RPC Rev. 06-22-21 | pg. 3/3
REMOTE POWER CONTROL: OPTIONS
TCR
Surge ecProt tion
Remote
Power Cont ol
ON
Switch
Common
V+
Active When Lit
Mode
Normal
Test
No connection
TCR
Surge ecProt tion
Remote
Power Control
ON
Switch
Common
V+
Do NOT co ecnn t V+ to
‘Common’ or ‘Switch’ terminals
Switch
Common
N. .O
Normally Open
N.C.
Normally Closed
Compatible
sequencer
REMOTE POWER CONTROL
using Lowell (classic) sequencer *
* NOTE: This unit is only compatible with a sequencer from the Classic
Connection series. It is not compatible with Pass-through sequencers.
For additional control connections, see the FAQ page on the
website (www.Lowellmfg.com/Resources). Power Question P3
REMOTE POWER CONTROL
using a switch or control system (by others)
that provides a maintained dry contact closure.
Active When Lit
Mode
Normal
Test
REMOTE POWER CONTROL
using Lowell RPS Series switches
TCR
Surge ectProt ion
Remote
Power Cont ol
ON
Active When Lit
Mode
Normal
Test
On
Maintained closure SPST
(single pole single throw) switch
with rocker or key activation
Switch
(Sw)
Com Com
V+
Switch
+24v
Green LED
3 conductor
Minimum Size: 24 ga.
Maximum Distance: 6000 ft.
AC power is applied
to receptacles when
connection is made
between “Common
and “Switch
terminals.
2.2K 1/2W
Resistor
Schematic


Produktspezifikationen

Marke: Lowell
Kategorie: Nicht kategorisiert
Modell: ACSP-1502-VTE
Breite: 228.6 mm
Tiefe: 152.4 mm
Gewicht: 4535 g
Produktfarbe: Schwarz
Höhe: 44.45 mm
Stecker: NEMA 5–15P
AC Eingangsfrequenz: 60 Hz
Kabellänge: 1.8 m
LED-Anzeigen: Status
Anzahl der AC-Ausgänge: 2 AC-Ausgänge
AC-Steckertypen: NEMA 5–15R
Nominale Eingang Spannung: 120 V
Gewährleistungsfrist: 10 Jahr(e)
Nominale Stromabgabe: 15 A
Überstromschutz: Ja
Anstieg der Energiemenge: 72000 J

Brauchst du Hilfe?

Wenn Sie Hilfe mit Lowell ACSP-1502-VTE benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Lowell

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-