Joblotron JK-16 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Joblotron JK-16 (2 Seiten) in der Kategorie Sicherheitskamera. Dieser Bedienungsanleitung war für 36 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
JK-16 PROFI 4/4 MGK24401
Control panel drilling template
JK-16 PROFI 1/4 MGK24401
JK-16 PROFI
• Installation instructions - only Jablotron distributor certified installers should install this kit.
• Detailed manuals for all included components can be found on the enclosed CD or on the Jablotron website
www.jablotron.com
1. Kit contents
All items in the kit are enrolled and preprogrammed. The
detectors and remote controls have batteries pre-installed.
Item description address
JA-60N wireless door sensor 1
JA-60P wireless motion detector 2
JA-63F wireless keypad c1
RC-44 remote control c2
UC-260 wireless indoor siren panel is enrolled
The RC-42 is the same remote control as the RC-44 except
that it is built into a housing with only two buttons ( & ), which
have identical functions to the left pair of RC-44 buttons.
2. Before installation
Decide upon suitable locations for all of the devices. The
wireless keypad should be within 20m of the control panel.
There should be power and a telephone line available for the
control panel.
3. Control panel installation
a) Install the control panel - see the drilling template on the
last page of this manual.
b) Install and connect the backup battery to the control panel
c) Connect the AC power to the control panel
d) The Green LED should flash in the control panel
e) Connect the keypad’s batteries (pull out the red tape to
activate batteries). P will be indicated on the keypad
(programming mode).
• If F is indicated, there is no communication with the control
panel.
• Enter F0 6060 to re-enter P mode if you accidentally exit it
by pushing the N key
To save the keypad batteries, close its cover.
RESET
Green LED
JK-16 PROFI 2/4 MGK24401
4. Detector and accessory installation
a) Install the JA-60N magnetic detector onto the door
(antenna pointing up or down)
b) Install the JA-60P PIR motion detector
c) Select Instant or Delay reactions via the DIP switches
inside the detectors.
d) Connect the detector’s batteries (pull out the red tape to
activate the batteries)
e) Attach the keypad to the desired location
f) Plug the UC-260 wireless siren into a power socket
g) Test the wireless doorbell button and install it.
5. Enrollment of additional accessories
If you install additional detectors (max. 32), you have to enroll
them. The system should be in P mode (if not enter F0 6060):
a) Press 1 to enter enrollment mode*
b) The next free detector position will be displayed on the
keypad.
c) Install batteries into all new detectors step by step to enroll
them (system will automatically offer the next free position)
d) To scroll through sensor positions, press 1 (up) or 7 (down)
e) To enroll a second detector to an occupied position press 5
before you install the detector’s batteries
f) To exit enrollment mode press the N key
The wireless keypad (JA-63F) enrolls after you install its
battery while in enrollment mode.
The remote control (RC-4x) enrolls after you press and hold
both and buttons while in enrollment mode.
The wireless outdoor siren (JA-63A) enrolls after it is
powered up while in enrollment mode
To enroll the control panel to UC receivers enter 299 on
the keypad while in P mode
Check individual device manuals for more details
• *Enrollment mode will also start after shorting the reset pins
in the control panel while it is in P mode.
6. Detector and controller testing
a) The system should be in P mode (if not enter F0 6060)
b) Trigger detectors – their addresses (1=door and 2=PIR) should
be indicated (if the PIR detector does not react, re-enter test
mode by opening and closing its cover)
c) Press button on the RC-4x remote control – c2 will be
indicated
7. To measure the strength of the radio signal
a) While in P 1 7 1 mode, press and then using scroll to position
b) Press 8 to start measuring
c) Activate the door detector to view its signal strength
d) Using the 1 key, scroll to the next position (2 PIR) and
check its signal strength (if the PIR detector does not react,
reenter its test mode by opening and closing its cover)
e) Repeat step d) to check all enrolled items. The wireless keypad
(c1) signal is indicated after you trigger its tamper. The remote
control (c2) is indicated after you press it’s button.
f) Change the location of an item if its signal is lower than 2
g) Return to P mode by pressing the N key
8. Programming the system
a) The system should be in P mode (if not enter F0 6060)
b) Using the following sequences you can program:
Function Sequence Comments
Your installer code* 5 xxxx xxxx 6060 factory default
xxxx new code
Exit delay 20x 3=30sec factory def.
Entrance delay 21x 3=30 sec factory def.
Alarm duration 22x 4=4min factory def.
Time & date 4 hh mm DD MM YY
See control panel installation manual for more details.
• Must be changed
•
9. Finishing the installation
a) Fill in the information on the sticker label and attach it inside
the keypad cover.
b) Switch the system to standby (by pressing the N key)
c) Instruct the user on how to operate the system
A
attach
C
open
B
click
rear tamper
lever
Don't tight
this screw
2
2,5
1,5
1
0,5
1,6 3,7 12 range [m]
height
[m]
120
ÅŸ
12m
zone A
zone B
zone C
zone A
zone B
zone C
JA-60P coverage
avoid locations against windows or close to a heater
JK-16 PROFI 3/4 MGK24401
10. Keypad operation
11. Specifications
Power 230 VAC, max 0.1 A, supervised, class II
Power supply A type (EN 50131-6)
Backup battery 12 V, 2.26 Ah, normal life time 5 years
Backup power output 13VDC, the max. permanent current is 0.4
or 1A for max. 15 min (1 cycle per hour),
Consumption of the control panel is 30 mA; JA-60E 25 mA
Hard-wired inputs 4 input zones, selectable triggering:
Wireless zones 16 zones (2 detectors can be enrolled to each
Wireless controllers max. 8 (JA-60F, RC-22, RC-44)
Access codes master code and 14 user codes.
Wired outputs Alarm relay dry contacts 1A/60V;
Programmable outputs PgX , PgY connect to the GND max. 0,1 A
Siren output 12 V, 0.7 A
Working frequency* 433.92 MHz; digital hopping code; supervised
communication
Comply with EN 50131-1, EN 50131-6
Security grade 2 (low to medium risk)
Environmental class II indoor – general (-10 to 40oC)
Safety EN 60950-1
EMC ETS 300683
Radio characteristics ETSI EN 300220
Can be operated according to ERC REC 70-03
Jablotron Alarms a.s. hereby declares that the JA-83K “OASiS“
control panel is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Dispose of batteries safely depending on the type of the
batteries and local regulation. Although this product does not
contain any harmful materials we suggest you to return the
product to the dealer or directly to the producer after usage.
Entry Function
User code Arming / Disarming (Setting\Unsetting)
F1 / Arming without a code
F2 / Partial arming
F3 / Door lock opening
F4 Memory reading
F5 New master code (example: F5 1234 2789 2789)
F6 User codes setting (example: F6 1234 03 3344)
F7 / Disarming under duress
F8 Appliance control (F81 = ON, F80 = OFF)
F0 M.code User test mode (example F0 1234)
N Escape & fault detail reading
Motion detector
JA-60P
Doors, Windows
JA-60N
Wireless keypad
JA-63F
Remote control
RC-4x
Indoor siren
UC-260
(230 V AC)
Control panel
JA-63KR
Power (230 V AC)

Produktspezifikationen

Marke: Joblotron
Kategorie: Sicherheitskamera
Modell: JK-16

Brauchst du Hilfe?

Wenn Sie Hilfe mit Joblotron JK-16 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Sicherheitskamera Joblotron

Bedienungsanleitung Sicherheitskamera

Neueste Bedienungsanleitung für -Kategorien-