SB1 OPTICAL SMOKE ALARM
USER MANUAL
Optical smoke alarms are suitable for detecting slow smouldering fires. Like other smoke alarms, they can be subject to nuisance alarms
from steam and should not be placed near bathrooms.
For the earliest warning, we recommend smoke alarms are fitted in all rooms where the temperature is between 0°C (32°F) and 40°C (104°F).
Prolonged exposure to temperatures outside those stated above will reduce product life.
Check with local building and fire regulations for your property, to ensure compliance.
This smoke alarm is suitable for use in mobile homes and caravans. This smoke alarm is not intended for any non-residential, commercial or
industrial application, nor for any other purpose than described.
© 2018 Sprue Safety Products Ltd.
Vanguard Centre, Coventry CV4 7EZ,
United Kingdom.
www.sprue.com
300mm
300mm
150mm
150mm
600mm
1. POSITIONING
Your smoke alarm is suitable for the
landing, hallway, bedroom, living room
and dining room.
Smoke alarms should be sited at least
300mm from light fittings and walls.
Ideally as central as possible in the room.
Smoke alarms should be positioned at
no more than 600mm vertically below the
highest point in the room.
If positioning your smoke alarm on the
wall, the top of the detection element
must be between 150mm and 300mm
below the ceiling, and at least 300mm
from any neighbouring wall.
1
The red operational LED on the front of the alarm should flash behind the plastic surface once every 32 seconds (approx.) to show that the alarm
is active.
Do not use any other test method except the
process described in this manual.
Remove the base plate from the
alarm by twisting it anti-clockwise
and insert the battery.
Fit the baseplate to ceiling
using the screws provided.
Push and twist the alarm
clockwise onto the base plate.
2c 2d
2b2a
2. INSTALLATION 3. MAINTENANCE
3a Test the alarm every month.
Replace the alarm every 10
years
3b Vacuum your alarm
every 3 months.
3c Do not use cleaners
or solvents. 3d Do not paint the alarm.
Smoke alarms can react to cooking fumes or other non emergency situations. Your alarm features ‘Silence’ technology. In the event of a
known false alarm you can temporarily silence it by pressing the test button. The red operational LED on the front of the alarm will flash
behind the plastic surface once every 8 seconds to show that it is in Silence mode. Your alarm will automatically return to full sensitivity
after 8 minutes. The alarm will sound continuously and the Red operational LED flashes behind the plastic surface every second when the
alarm senses smoke.
NEVER IGNORE ANY ALARM. If an alarm is sounding, it is warning you of a potentially hazardous situation. Do not ignore it. Ignoring the
alarm may result in injury or death. If your smoke alarm activates and you are not absolutely certain of the source of smoke, get everyone
out of the house immediately.
In a known false alarm, the alarm can be silenced temporarily.
The alarm will silence for 8
minutes.
4. SILENCE FEATURE
4b4a
3e
TROUBLESHOOTING GUIDE
Sprue Safety Products Ltd warrants to the original purchaser that its enclosed smoke alarm be free from defects in materials and workmanship
under normal residential use and service for a period of 3 (three) years from the date of purchase (not including the replaceable battery).
Provided product is sent back to Sprue Safety Products with proof and date of purchase, Sprue Safety Products Ltd hereby warrants that
during the 3 (three) year period commencing from the date of purchase Sprue Safety Products Ltd, at its discretion, agrees to replace the unit
free of charge. The warranty on any replacement SB1 alarm, will last for the remainder of the period of the original warranty in respect of the
alarm originally purchased – that is from the date of original purchase and not from the date of receipt of the replacement product. Sprue
Safety Products Ltd reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or
in stock. This warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable. Proof of purchase
is required.
This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or
applications not in accordance with the user manual. It does not cover events and conditions outside of Sprue Safety Products Ltd’s control,
such as Acts of God (fire, severe weather etc.). It does not apply to retail stores, service centres or any distributors or agents. Sprue Safety
Products Ltd will not recognise any changes to this warranty by third parties.
Sprue Safety Products Ltd shall not be liable for any incidental or consequential damages caused by the breach of any expressed or implied
warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited
in duration for 3 (three) years.
This warranty does not affect your statutory rights. Except for death or personal injury, Sprue Safety Products Ltd shall not be liable for any
loss of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by you or
any other user of this product.
DISPOSAL
Waste electrical products should not be disposed of with your other household waste. The alarm is ideally suited for disposal within the
waste electronic and electrical equipment (WEEE) recycling scheme.
Please recycle where facilities exist. Check with your local authority, retailer or contact our Technical Support team for recycling/disposal
advice as regional variations apply. The batteries should be removed before disposal of the detector. Both the batteries and the detector
should be disposed of in line with current regulations.
Do not attempt to open. Do not burn.
WARRANTY AND DISPOSAL
0359-C PR-0064 9
EN 4604:2 C:21 005 A + 008
Smo alke a srm device
DoP: SADOP-SB1-01
18
6. FAULT INDICATION
6a If there is a fault, the alarm will ‘chirp’ every
32 seconds followed by 2 Red operational
LED flashes behind the plastic surface.
If the alarm is still within warranty,
contact Technical Support.
6b
8
+
-
Your alarm requires 1 x 9V (PP3) battery. Under normal use, the battery should last approximately one year. Use of a battery other than those
recommended here may have a detrimental effect on the alarm: DC9V Gold Peak GP1604S, Raymax 6F22.
Technical Support
Online: www.fireangel.co.uk/support
E-mail: technicalsupport@fireangel.co.uk
Phone: 0800 141 2561 (EIRE Phone: 1-800 523 171)
Note: This user manual is also available in large text and
other formats. Please email: technicalsupport@sprue.com
or call 0800 141 2561 for further information.
GN5040R4
If your smoke alarm does
not sound during testing:
If your smoke alarm
activates when no smoke
is visible:
If your smoke alarm
sounds unusual or
‘chirps’ intermittently:
If you experience
frequent unwanted
alarms:
• Check that your battery is connected.
• If testing after first installation, allow a few seconds for the alarm to settle.
• Push and hold the centre of the test button firmly.
• If the alarm has been silenced and is in low sensitivity mode it may not test.
Wait 15 minutes then try again.
• Replace the battery.
• Check the location of your smoke alarm.
• Clean the smoke alarm.
• Check the location of your smoke alarm.
• Clean the smoke alarm.
• Check that your smoke alarm is definitely the source of the chirping; make sure the
noise isn’t coming from another alarm.
• Check the location of your smoke alarm.
• Clean the smoke alarm.
ALARM TEST:
Press and hold the test
button for 5 seconds.
The alarm will sound.
Press and hold the test
button for 5 seconds.
5. LOW BATTERY WARNING
5a Replace the battery
immediately.
5b Always test the
alarm after replacing
the batteries.
5c
+
-
+
-
When the alarm battery is low,
the alarm will ‘chirp’ and the
Red operational LED will flash
once every 32 seconds behind
the plastic surface.
Produktspezifikationen
Marke: | FireAngel |
Kategorie: | Rauchmelder |
Modell: | SB1-T |
Brauchst du Hilfe?
Wenn Sie Hilfe mit FireAngel SB1-T benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Rauchmelder FireAngel
7 Oktober 2024
22 September 2024
16 September 2024
5 September 2024
2 September 2024
1 September 2024
28 August 2024
28 August 2024
28 August 2024
28 August 2024
Bedienungsanleitung Rauchmelder
- Rauchmelder Hama
- Rauchmelder Nedis
- Rauchmelder Trust
- Rauchmelder Brennenstuhl
- Rauchmelder Clas Ohlson
- Rauchmelder Cotech
- Rauchmelder REV
- Rauchmelder Bosch
- Rauchmelder Siemens
- Rauchmelder Eminent
- Rauchmelder IKEA
- Rauchmelder Schwaiger
- Rauchmelder Alecto
- Rauchmelder Denver
- Rauchmelder EMOS
- Rauchmelder Gira
- Rauchmelder König
- Rauchmelder MarQuant
- Rauchmelder TFA
- Rauchmelder Blaupunkt
- Rauchmelder Pyle
- Rauchmelder Vivanco
- Rauchmelder Abus
- Rauchmelder Elro
- Rauchmelder Olympia
- Rauchmelder Smartwares
- Rauchmelder Yale
- Rauchmelder Ferguson
- Rauchmelder Gigaset
- Rauchmelder Nexa
- Rauchmelder GEV
- Rauchmelder Gloria
- Rauchmelder Honeywell
- Rauchmelder B/R/K
- Rauchmelder First Alert
- Rauchmelder Flamingo
- Rauchmelder Netatmo
- Rauchmelder Hager
- Rauchmelder Bavaria
- Rauchmelder JUNG
- Rauchmelder Nest
- Rauchmelder Ei Electronics
- Rauchmelder Kidde
- Rauchmelder Kogan
- Rauchmelder M-e
- Rauchmelder Stabo
- Rauchmelder HQ
- Rauchmelder Busch-Jaeger
- Rauchmelder Swann
- Rauchmelder Sygonix
- Rauchmelder Chuango
- Rauchmelder FlammEx
- Rauchmelder Insafe
- Rauchmelder Pyrexx
- Rauchmelder Homematic IP
- Rauchmelder EQ3
- Rauchmelder Elgato
- Rauchmelder ESYLUX
- Rauchmelder Fito
- Rauchmelder Fito Profi-line
- Rauchmelder Indexa
- Rauchmelder Interlogix
- Rauchmelder KlikaanKlikuit
- Rauchmelder Mercury
- Rauchmelder Satel
- Rauchmelder Steren
- Rauchmelder X-Sense
- Rauchmelder Dahua Technology
- Rauchmelder Inovonics
- Rauchmelder Heatit
- Rauchmelder Pentatech
- Rauchmelder H-Tronic
- Rauchmelder FireX
- Rauchmelder Lupus Electronics
- Rauchmelder System Sensor
- Rauchmelder Malmbergs
- Rauchmelder Chacon
- Rauchmelder Fibaro
- Rauchmelder ORNO
- Rauchmelder WisuAlarm
- Rauchmelder Cavius
- Rauchmelder DSC
- Rauchmelder Cordes
- Rauchmelder STI
- Rauchmelder Deltronic
- Rauchmelder Minute Man
- Rauchmelder Gewiss
- Rauchmelder Calex
- Rauchmelder Mobeye
- Rauchmelder Qolsys
- Rauchmelder Ajax
- Rauchmelder AngelEye
- Rauchmelder FirstAlert
- Rauchmelder FireHawk
- Rauchmelder ETiger
- Rauchmelder TEF
- Rauchmelder Jalo Helsinki
- Rauchmelder Pristine
- Rauchmelder Jemay
- Rauchmelder Mircom
- Rauchmelder BRK DICON
- Rauchmelder Egardia
- Rauchmelder Frient
- Rauchmelder SAVS
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
14 Oktober 2024
14 Oktober 2024
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
8 Oktober 2024
4 Oktober 2024
3 Oktober 2024