Elite Screens KestrelTension FTE85C Bedienungsanleitung
Elite Screens
Projektionsfläche
KestrelTension FTE85C
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Elite Screens KestrelTension FTE85C (5 Seiten) in der Kategorie Projektionsfläche. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/5
Portable Floor Rising
Tensioned
Screen
Kestrel Tension Series
USER’S GUIDE
I ort t Safety Notesmp an
1. Please read this manual before use and follow the procedures specified:
a. Please retain this manual for future reference.
b. To avoid any damages to the screen, do not use any accessories or parts not recommended
by Elite Screens.
c. Handle the device carefully during transportation.
d. Do not set up screen on uneven surfaces.
e. To prevent electrical shock or fire; never over load the power cord, and avoid contacting
the motorized components with liquids or foreign objects.
2. The tubular motor equipped in the electric screen Kestrel Tension models feature an
overheat protection sensor. If the screen is consecutively brought up and down between 3-4
minutes, the motor will automatically shut-off to prevent the motor from sustaining damage
through overheating. If the automatic shutoff is activated, please allow 30 minutes cool
down time before resuming operation.
3. The Kestrel Tension Series Screen is equipped with a strong tension cross-spring system. Please
do not attempt any unnecessary repairs. It is at your own risk to open the inside cover or
dismantle/work on the screen. Individual modification to thi product are prohibited as s nd
will void the user warranty. ’s
4. When using the screen, please
a. Avoid strong wind, rain, or electrical storms.
b. No direct sunshine (UV Radiation) or m sture. oi
c. K p away f m re sour and high temperature devices. ee ro fi ces
d. Turn off the power before moving or maintaining this product.
Keep away from drenchil
Keep hands clear
from the closing
Rev. 2 www.elitescreens.com 6/26/2015
NOTE:
This equip nt has been tested and found to comply with the limi for a dig ame ts Class B it l
device pursuant to Part 15 of the FCC Guidelines.
The products ar sig d provid reasonabl prot tion agains rmfu interference de ne to e e ec t ha l e
in residential/commercial installat n and end user application and may radiate radio a io
frequency energy .
However, there is no g rantee that interference will not occur in a particular installation. If this ua
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. The power ou et should b close to the un and e i acce ible. tl e it as ly ss
2. Re-orient or relocat the receiving antenna.e
3. Increase the separation between the equipment and the receiver.
4. Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
5. Consult the dealer or an perien d radio/TV t hnician for additional help. ex ce ec
Accessorie Kestrel Tension Seriess for
Opti al Accessorie Kestrel Tension Serieson s for
Qty 1
In-wall RJ45
module
AAA Batteries x 2
Qty 1
5-12V DC
Trigger
Qty 1
IR “eye”
Receiver
Qty 1
Radio Frequency
Remote Control
Qty 1
Infrared Remote
Control
Qty 1
Low Voltage 3-way
Wall Switch
QTY 1
Wireless 5-12V Trigger
Part# -ZSP-TR02
Rev. 3 www.elitescreens.com 6/26/2015
Operating the Kestrel Tension Series Screen
Setup:
Remo the controls and wiring from the compartment the left de ofve on si
the Kestrel Tension
Floor Electric Screen shown the pictures below. as in
Connect the screen to the power supply and switch the power button on. Now it is ready for use.
Power:
About the Control System:
1. Wireless 5-12V Trigger: The ZSP-TR02 Wireless 5-12V trigger for your new Elite Kestrel allows
your screen to synchronize its rise and drop with the projectors power cycle by connecting the output
trigger, which is typically located on the back of most projectors, and the RF remote control via the ZSP-
TR02 cable. The screen rises when the projector powers up and retracts when the projector powers down.
2. RF (Radio Frequency) and Optional IR (Infrared) Remotes: The Kestrel Tension Series screen
includes both IR and RF receivers that enable the consumer to use either the RF or an optional IR remote
control. The RF remote is best used when the screen is concealed or long distance control is required. The
RF technology therefore more versatile as it does not require line of to operate the screen. The optional IR
requires a direct line of sight through the screen’s IR receiver window.
3. -wall RJ-45 Module In : The RJ-45 module connects to a local wall switch for Up/Down control of
your electric projection screen. Please follow the picture diagram below for instructions on how to
connect this accessory.
ON OFF
IR receiver window
Produktspezifikationen
Marke: | Elite Screens |
Kategorie: | Projektionsfläche |
Modell: | KestrelTension FTE85C |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Elite Screens KestrelTension FTE85C benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Projektionsfläche Elite Screens
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
Bedienungsanleitung Projektionsfläche
- Projektionsfläche Da-Lite
- Projektionsfläche Pyle
- Projektionsfläche Optoma
- Projektionsfläche Kodak
- Projektionsfläche NEC
- Projektionsfläche Celexon
- Projektionsfläche Elite
- Projektionsfläche AV:link
- Projektionsfläche Draper
- Projektionsfläche Oregon Scientific
- Projektionsfläche Duronic
- Projektionsfläche GPX
- Projektionsfläche Luxburg
- Projektionsfläche EluneVision
- Projektionsfläche Stewart
- Projektionsfläche Lumene
- Projektionsfläche Avers
- Projektionsfläche Elite ProAV
- Projektionsfläche KHOMO GEAR
- Projektionsfläche EPV
Neueste Bedienungsanleitung für -Kategorien-
12 Oktober 2024
2 Oktober 2024
29 September 2024
27 September 2024
20 September 2024
11 September 2024
7 September 2024
6 September 2024
6 September 2024
5 September 2024