Eastron SDM530D Bedienungsanleitung


Lesen Sie kostenlos die đŸ“– deutsche Bedienungsanleitung fĂ¼r Eastron SDM530D (10 Seiten) in der Kategorie Messgeräte. Dieser Bedienungsanleitung war fĂ¼r 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/10
Three phase din rial meter user manualSDM530D
JIAXING EASTRON ELECTRONIC INSTRUMENTS CO., TLD.
Address: No.1369, Chengnan Road, Nanhu, Jiaxing, Zhejiang, China
Tel: +86-573-83698881 83698882 Fax: +86-573-83698883
Email: Web: www.eastrongroup.comsales@eastrongroup.com
SDM530D
THREE PHASE FOUR WIRE ENERGY METER WITH S0 PULSE OUTPUT
(SEVEN MODULE)
User manual
------------
1.1
Safety
instruction
1.2
Foreword
1.3
Performance
criteria
1.4
Specifications
1.5
errors
1.6
Dimension
&
material
1.7
Installation
1.8
Operating
1.9
CT
ratio
setting
(SDM530D
CT
only)
1.10
Technical
support
Three phase din rial meter user manualSDM530D
JIAXING EASTRON ELECTRONIC INSTRUMENTS CO., TLD.
Address: No.1369, Chengnan Road, Nanhu, Jiaxing, Zhejiang, China
Tel: +86-573-83698881 83698882 Fax: +86-573-83698883
Email: Web: www.eastrongroup.comsales@eastrongroup.com
1.1 Safety instructions
Information for Your Own Safety
This manual does not contain all of the safety measures for operation of the equipment (module,
device), because special operating conditions, and local code requirements or regulations may
necessitate further measures. However, it does contain information which must be read for your
personal safety and to avoid material damages. This information is highlighted by a warning triangle
and is represented as follows, depending on the degree of potential danger.
Warning
This means that failure to observe the instruction can result in death, serious injury or
considerable material damage.
Caution
This means hazard of electric shock and failure to take the necessary safety
precautions will result in death, serious injury or considerable material damage.
Qualified personnel
Operation of the equipment (module, device) described in this manual may only be performed by
qualified personnel. Qualified personnel in this manual means person who are authorized to
commission, start up, ground and label devices, systems and circuits according to safety and
Regulatory standards.
Use for the intended purpose
The equipment (device, module) may only be used for the application specified in the catalogue and
the user manual, and only be connected with devices and components recommended and approved
by Eastron Electronic.
Proper handling
The prerequisites for perfect, reliable operation of the product are proper transport, proper storage,
installation and assembly, as well as proper operation and maintenance. When operating electrical
equipment, certain parts of this equipment automatically carry dangerous voltages. Improper
handling can therefore result in serious injuries or material damage.

Use
only
insulating
tools
.

Do
not
connect
circuit
is
live
(hot)
.

Place
the
meter
only
in
dry
surroundings
.

Do
not
mount
the
meter
in
an
explosive
area
or
expose
the
meter
to
dust,
mildew
and
insects.

Make
sure
the
used
wires
are
suitable
for
the
maximum
current
of
this
meter
.

Make
sure
the
AC
wires
are
connected
correctly
before
activating
the
current/voltage
to
the
meter.

Do
not
touch
the
meter
connecting
clamps
directly
with
your
bare
hands,
with
metal,
blank
wire
or other material as you may get an electrical shock.

Make
sure
the
protection
cover
is
placed
after
installation
.

Installation,
maintenance
and
reparation
should
only
be
done
by
qualified
personnel
.

Never
break
the
seals
and
open
the
front
cover
as
this
might
influence
the
functionality
of
the
meter, and will avoid any warranty.

Do
not
drop,
or
physical
impact
to
the
meter
as
there
are
high
precision
components
inside
that may break.
Three phase din rial meter user manualSDM530D
JIAXING EASTRON ELECTRONIC INSTRUMENTS CO., TLD.
Address: No.1369, Chengnan Road, Nanhu, Jiaxing, Zhejiang, China
Tel: +86-573-83698881 83698882 Fax: +86-573-83698883
Email: Web: www.eastrongroup.comsales@eastrongroup.com
Disclaimer
We have checked the contents of this publication and every effort has been made to ensure that the
descriptions are as accurate as possible.
However, deviations from the description cannot be completely ruled out, so that no liability can be
accepted for any errors contained in the information given. The data in this manual is checked
regularly and the necessary corrections are included in subsequent editions. We are grateful for any
improvements that you suggest.
Subject to technical modifications without notice.
Copyright
Copyright Eastron Electronic Instruments Co., Ltd. All rights Reserved.
It is prohibited to pass on or copy this document or to use or disclose its contents without our express
permission. Any duplication is a violation of the law and subject to criminal and civil penalties. All
rights reserved, particularly in the event of a patent award or utility model registration.
1.2 Foreword
the Eastron SDM530D DIN rail three phase four wire energy meter. The Eastron SDM530D energy
meter is the most advanced type electronic kWh meter available at the market. With the Eastron
product range we have introduced a large scale of energy meters on the market suitable for 110V AC
to 400V AC (50 or 60Hz).
The Eastron SDM530D has two versions, direct connection version and CT connection version. The
direct connection version SDM530D can be connected to load up to 100A. While the SDM530D CT
version shall be connected with 5A secondary output current transformer. The CT ratio can be
programmable via the buttons on the front panel.
The meter adopts big size LCD display with a highlight blue color backlit. The backlit has 3 modes
(always on, always off, on for 30seconds after each button click) programmable from the front button.
With high accuracy and long lifespan design, the SDM530D is a perfect option for any three phase
applications. 18 month quality warranty is offered, Eastron is responsible for replacement of any
failure meters, which caused by production or design mistake.
1.3 Performance criteria
Operating humidity ≤ 85%
Storage humidity ≤ 95%
Operating temperature -10°C-+50°C
Storage temperature -30°C-+70°C
International standard IEC 62053-21
Accuracy class 1
Protection against penetration of dust and water IP51
Insulating encased meter of protective class â…¡


Produktspezifikationen

Marke: Eastron
Kategorie: Messgeräte
Modell: SDM530D

Brauchst du Hilfe?

Wenn Sie Hilfe mit Eastron SDM530D benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Messgeräte Eastron

Bedienungsanleitung Messgeräte

Neueste Bedienungsanleitung fĂ¼r -Kategorien-