INSTALLATION AND OPERATING INSTRUCTIONS FOR
Single Motor Low Voltage
Control System
2
Low Voltage Connections
The low voltage control (LVC) housing is divided into 3 compartments. the compartment labeled Low Voltage Connections is where
you will connect the wall switch or a central control panel. The compartment labeled “AC Power Connections is where the main power
and motor wire connections are made. The center compartment only requires access when connecting an infrared or radio frequency
remote receiver.
Wall Switch
WARNING: This unit must be used with the enclosed switch.
DO NOT USE the rocker switch included with screen.
AVERTISSEMENT: Cette unité doit être utilisée avec
l'interrupteur fourni. NE UTILISEZ PAS l'interrupteur à
bascule fourni avec l'écran.
1. Install wall switch where desired.
2. Use 3-conductor 2024 gauge wire to extend the switch wire to
the required length.
3. Connect the wire from the switch to the wire labeled “wall switch”.
Refer to diagram 1.
CAUTION: Never apply voltage to the wall switch lead or the
LVC will be damaged.
ATTENTION: N'appliquez jamais une tension aux ils du
commutateur mural sinon le tableau de contrôle basse
tension sera endommagé.
Control Panel
A control panel may be connected to the LVC by using the wall
switch wire lead. The control panel must provide a momentary,
dry contact closure of at least 1/2 second.
1. Use 3-conductor 2024 gauge wire to connect the control panel
to the wall switch lead.
2. A momentary closure across the white and red wires will be an
“up command.
3. A momentary closure across the white and black wires will be a
down” command.
4. A momentary closure across the white, red and black wires will
be a “stop” command.
CAUTION: Never apply voltage to the wall switch lead or the
LVC will be damaged.
ATTENTION: N'appliquez jamais une tension aux ils du
commutateur mural sinon le tableau de contrôle basse
tension sera endommagé.
Recommended Wire Size:
2024 AWG
Low-Voltage
Wall Switch
Black
Black
Red
White
Figure 1
Up
Stop
Down
Important Safety Instructions
When using your video equipment, basic safety precautions should always be followed, including the following:
1. Read and understand all instructions before using.
2. Position the cord so that it will not be tripped over, pulled, or
contact hot surfaces.
3. If an extension cord is necessary, a cord with a current rating at
least equal to that of the appliance should be used. Cords rated
for less amperage than the appliance may overheat.
4. To reduce the risk of electric shock, do not disassemble this
appliance. Contact an authorized service dealer when repair
work is required. Incorrect reassembly can cause electric shock
when the appliance is used subsequently.
5. The use of an accessory attachment not recommended by the
manufacturer may cause a risk of ire, electric shock, or injury to
persons.
Save These Instructions
WARNING: To prevent electrical shock or damage to the
LVC, do not apply power to the LVC until all connections
are complete. Make sure power is turned of on all wires
before making connections.
AVERTISSEMENT: pour éviter tout choc électrique ou
d'endommager le tableau de contrôle basse tension,
n'alimentez ce dernier qu'une fois tous les branchements
efectués. Vériiez qu'aucun câble n'est alimenté avant
d'efectuer les branchements.
Pre-Installation
3
AC Power Connections
Optional Wireless Remote Connections:
Optional RF Remote,
IR Remote Or Video Projector
Interface Connector
Optional RF Remote,
IR Remote Or Video Projector
Interface Connector
EYE AUX
EYE AUX
120VAC 60Hz 240VAC 50Hz
Radio Frequency Remote
1. Remove the cover plate labeled “Low voltage connections” and
the center cover plate.
2. Route the receiver wire through the round plastic bushing and
plug it into the onboard socket marked “EYE”. Refer to diagram 4.
Infrared Remote
1. Remove the cover plate labeled “Low voltage connections” and
the center cover plate.
2. Route the receiver wire through the round plastic bushing and
plug it into the onboard socket marked “EYE”. Refer to diagram 4.
Figure 4
Screen Motor
1. Connect the motor wires in the screen junction box to the
LVC wires labeled “motor wires”. Refer to diagram 2.
2. Use 1418 gauge wire to extend the motor wire to the
required length.
Screen
White-White
120VAC 60Hz 240 VAC 50Hz
Figure 2
Black-Black
Green
Ground
Red-Red
Up
Stop
Down
Up
Stop
Down
Ground Lug
Screen
Green/Yellow
Ground Ground Lug
Recommended Wire Size:
1418 AWG
Recommended Wire Size:
1418 AWG
Blue-Blue
Brown-Brown
Black-Black
AC Power Source
1. Connect power wires to the LVC wires labeled “AC power input”.
Refer to diagram 3.
2. Connect the building ground wire to the ground lug on the
metal housing.
Power
Source
120VAC
60HZ
Green Ground
Ground Lug
UP
STOP
DOWN
Power
Source
240VAC
50HZ
Green Ground
White Common Blue Common
Ground Lug
Black Hot Brown
Hot
Figure 3
Up
Stop
Down
Recommended Wire Size:
1418 AWG
Recommended Wire Size:
1418 AWG


Produktspezifikationen

Marke: Da-Lite
Kategorie: Nicht kategorisiert
Modell: 40973

Brauchst du Hilfe?

Wenn Sie Hilfe mit Da-Lite 40973 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Da-Lite

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-