WHALE Orca 500 Bedienungsanleitung
WHALE
Wasserpumpe
Orca 500
Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr WHALE Orca 500 (28 Seiten) in der Kategorie Wasserpumpe. Dieser Bedienungsanleitung war fĂĽr 24 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/28
INSTALLATION AND OPERATION MANUAL
Orca Submersible Pump Range
* (B) suffix represents a bulk item code
Model Number Description
BE0500 Orca 500 - 12 V d.c.
BE0950 Orca 950 - 12 V d.c.
BE1450 Orca 1300 - 12 V d.c.
BE1454 Orca 1300 - 24 V d.c.
BE2002(B) Orca 2000 - 12 V d.c.
BE2004(B) Orca 2000 - 24 V d.c.
BE3002(B) Orca 3000 - 12 V d.c.
BE3004(B) Orca 3000 - 24 V d.c.
2
INSTALLATION AND OPERATION MANUAL
Thank you for purchasing this Whale® product. For over 60 years Whale® has led the way in the
design and manufacturer of freshwater and waste systems including:- plumbing, faucets, showers
and pumps for low voltage applications. The company and its products have built a reputation for
quality, reliability and innovation backed up by excellent customer service.
For information on our full product range visit: www.whalepumps.com
* Flow rates are stated in accordance with ABYC recommendations at a voltage of 13.6 V d.c.
The Orca submersible electric bilge pump range is designed for use as a bilge pump on marine
vessels. These high capacity pumps are compact and powerful, designed for bilge water evacuation.
Read the following instructions carefully before installing and using the equipment.
Check that the product is suitable for the intended application, follow these installation instructions
and ensure all relevant personnel read the points listed below. Also ensure that these operating
instructions are passed on to the end user.
This Whale Orca Electric Bilge Pump is designed for use as a bilge pump in marine vessels to pump
bilge water only.
1. This pump outlet must be mounted at least 305mm (12”) above the water
line when connected to an intake located below the water line.
2. Not suitable for pumping flammable liquids, diesel, chemicals etc. For use
in a bilge system only.
3. This pump is designed to exhaust standing water only. These pumps are not intended
for damage control. Bilge pump capacities may not be sufficient to prevent flooding
from rapid accumulation of water due to storms, rough weather and/ or rapid leaks
created by hull damaged and or unsafe navigational conditions.
4. With all applications, it is important that a system of safe working practice is applied to
installation, use and maintenance. Ensure the electric supply is turned off.
5. In order to securely fasten this unit, ensure that the mounting surface is a minimum
1. SPECIFICATION
2. PRINCIPALS OF OPERATION
3. TO THE USER
4. TO THE FITTER
Model 500 US GPH
(32 ltrs/min)
950 US GPH
(57 ltrs/min)
1300 US GPH
(82 ltrs/min)
2000 GPH
(126 ltrs/min)
3000 GPH
(189 ltrs/min)
Product Code BE0500 BE0950 BE1450 BE1454 BE2002(B) BE2004(B) BE3002(B) BE3004(B)
Open Flow Rate @
13.6 V d.c
500 GPH
(32 ltrs/min)
950GPH
(57 ltrs/min)
1300GPH
(82 ltrs/min)
2000 GPH
(126 ltrs/min)
3000 GPH
(189 ltrs/min)
Flow Rate @
1m (3ft) Head
450 GPH
(26ltrs/min)
850 GPH
(52 ltrs/min)
1100 GPH
(65 ltrs/min)
1650 GPH
(104 ltrs/min)
2700 GPH
(170 ltrs/min)
Nominal Voltage 12 V d.c. 24 V d.c. 12 V d.c. 24 V d.c. 12 V d.c. 24 V d.c.
Current Draw 1.5 amps 3.5 amps 5.0 amps 2.5 amps 10.0 amps 5.0 amps 18.0 amps 9.0 amps
Recommended Fuse 2.0 amps 5.0 amps 7.0 amps 5.0 amps 15.0 amps 8.0 amps 27.0 amps 13.0 amps
Weight 0.28 kg
(0.62lbs)
0.45 kg
(0.99lbs)
0.82 kg
(1.81lbs)
1.32 kg
(2.91lbs)
2.64 kg
(5.82lbs)
Hose Connections 3/4” (19 mm) 1” (25mm) and 1 1/8” (28mm) 1 1/8” (28mm) 1 1/4” (32mm)
Wire Size 1.3mm² (16 AWG) 2mm² (14 AWG)
Materials Pump body: ABS, Seals: Nitrile, :Impeller
Acetal
Pump body Seals: Polypropylene, : Nitrile,
Impeller: Acetal
Maximum Discharge
Head
3.0 m
(9.8 ft)
3.5 m
(11.5 ft)
4.5 m
(14.8 ft)
4m
(13ft)
4.6m
(15ft)
5. APPLICATION
6. WARNINGS
ENG
3
thickness of 19mm (3/4”). Do screw directly onto the hull, it must be mounted to NOT
a bulkhead or on an additional board.
1 x Orca Pump 1 x Screw Kit
BE9003 / BE9006 - Electric Field Sensor Switch (Available separately)
WARNING: Please note that incorrect installation may invalidate the warranty.
Preparation - Always disconnect power sources before installing.
9.1 Location
• Position pump in the lowest accessible
part of the bilge. On sailboats, location
should be centred over keel (Fig 1).
• mount the pump directly onto Do not
the hull. The base strainer must be
mounted to a bulkhead or an additional
board at least 19mm (3/4”) thick.
9.2 Mounting Instructions
Before drilling, ensure that the mounted pump will be correctly positioned with the pump nozzle
pointing towards thru-hull connector.
To remove pump body, place hand over body, depress locking tabs and lift body from strainer base.
Note: Motor will be removed with body (see figure 2 and 3).
For Orca 500, 950, 1300 and 2000
• Use base as template to mark 3 mounting holes for Orca in
mounting pad.
• Remove base. Drill three 1/8" (3mm) pilot holes for Orca at
marked locations.
• Replace base. Attach with #8 stainless steel fasteners
(supplied).
• Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figures 2
and 3).
For Orca 3000
• Use base as template to mark 4 mounting holes for Orca
3000 in mounting pad.
• Remove base. Drill four 1/8" (3mm) pilot holes for Orca
3000 at marked locations.
• Replace base. Attach with #8 stainless steel fasteners
(supplied).
• Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figure 3).
9.3 Plumbing
IMPORTANT: To prevent airlock, hose must rise continually upward to the thru-hull connector with
no dips or sharp bends. Hose support clips should be used at regular intervals where necessary.
• Orientate the pump outlet for a direct path to the hull connector ensuring an
unobstructed hose path.
• Secure all connections with hose clamps.
• If no thru-hull connector exists, install at 12" (305mm) minimum height above water
line. Apply marine sealant around thru-hull flanges on interior and exterior of hull.
7. PARTS LIST
9. INSTALLATION
Press both
locking tabs
to release
cover
Figure 2 - Release Cover
Orca 500, 950 and 1300
Press
both
locking
tabs to
release
cover
Figure 3 - Release
Cover Orca 2000
and 3000
8. OPTIONAL EXTRAS
Figure 1 -
Mounting Location
Skin Fittings
Suitable Mounting Pad
Hose must rise upwards
with NO DIPS
Outlet 12”
(305mm)
minimum
above
water line
Produktspezifikationen
Marke: | WHALE |
Kategorie: | Wasserpumpe |
Modell: | Orca 500 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit WHALE Orca 500 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Wasserpumpe WHALE
5 September 2024
5 September 2024
5 September 2024
5 September 2024
2 September 2024
14 August 2024
10 August 2024
3 August 2024
31 Juli 2024
13 Juli 2024
Bedienungsanleitung Wasserpumpe
- Wasserpumpe Cotech
- Wasserpumpe LG
- Wasserpumpe Makita
- Wasserpumpe Bosch
- Wasserpumpe Parkside
- Wasserpumpe Vonroc
- Wasserpumpe Cocraft
- Wasserpumpe Topcraft
- Wasserpumpe Trotec
- Wasserpumpe Dometic
- Wasserpumpe Atlantic
- Wasserpumpe Einhell
- Wasserpumpe Mitsubishi
- Wasserpumpe Eheim
- Wasserpumpe Eurom
- Wasserpumpe Hitachi
- Wasserpumpe Hyundai
- Wasserpumpe Metabo
- Wasserpumpe Kärcher
- Wasserpumpe GĂĽde
- Wasserpumpe Scheppach
- Wasserpumpe Meec Tools
- Wasserpumpe Fieldmann
- Wasserpumpe King Craft
- Wasserpumpe Westfalia
- Wasserpumpe Vaillant
- Wasserpumpe Remko
- Wasserpumpe Pattfield
- Wasserpumpe Silverline
- Wasserpumpe Sthor
- Wasserpumpe Maxxmee
- Wasserpumpe Florabest
- Wasserpumpe Germania
- Wasserpumpe Hecht
- Wasserpumpe Kranzle
- Wasserpumpe De Dietrich
- Wasserpumpe Wiltec
- Wasserpumpe Zipper
- Wasserpumpe Yato
- Wasserpumpe Fluval
- Wasserpumpe Tetra
- Wasserpumpe Vetus
- Wasserpumpe Viessmann
- Wasserpumpe Jabsco
- Wasserpumpe Dimplex
- Wasserpumpe Buderus
- Wasserpumpe Hayward
- Wasserpumpe Gre
- Wasserpumpe Bavaria
- Wasserpumpe Toolcraft
- Wasserpumpe Fujitsu
- Wasserpumpe JUNG
- Wasserpumpe Bestway
- Wasserpumpe Intex
- Wasserpumpe AL-KO
- Wasserpumpe Gardena
- Wasserpumpe CMI
- Wasserpumpe Alphacool
- Wasserpumpe SereneLife
- Wasserpumpe Neptun
- Wasserpumpe Bulex
- Wasserpumpe Danfoss
- Wasserpumpe Hozelock
- Wasserpumpe Eden
- Wasserpumpe Swim & Fun
- Wasserpumpe Nibe
- Wasserpumpe Daikin
- Wasserpumpe Norsup
- Wasserpumpe Duro Pro
- Wasserpumpe Duromax
- Wasserpumpe Eurogarden
- Wasserpumpe Ferrex
- Wasserpumpe Flojet
- Wasserpumpe Garden Feelings
- Wasserpumpe Gardenline
- Wasserpumpe Grizzly
- Wasserpumpe Hydro-Pro
- Wasserpumpe Kibani
- Wasserpumpe Maxicool
- Wasserpumpe Oase
- Wasserpumpe OKAY
- Wasserpumpe Plantiflor
- Wasserpumpe Tanaka
- Wasserpumpe Wingart
- Wasserpumpe Esotec
- Wasserpumpe Sunforce
- Wasserpumpe T.I.P.
- Wasserpumpe Wolfcraft
- Wasserpumpe Heissner
- Wasserpumpe DAB
- Wasserpumpe VT
- Wasserpumpe Truper
- Wasserpumpe JANDY
- Wasserpumpe Liberty Pumps
- Wasserpumpe Elpumps
- Wasserpumpe For_Q
- Wasserpumpe Pontec
- Wasserpumpe Ashland
- Wasserpumpe Proviel
- Wasserpumpe Zoeller
- Wasserpumpe Anova
- Wasserpumpe Yellow Garden Line
- Wasserpumpe Fiap
- Wasserpumpe Little Giant
- Wasserpumpe Waterco
- Wasserpumpe Ergotools Pattfield
- Wasserpumpe Sunnydaze Decor
- Wasserpumpe Ebara
- Wasserpumpe Pentair
- Wasserpumpe Flotide
- Wasserpumpe Ribimex
- Wasserpumpe Coral Box
- Wasserpumpe Nowax
- Wasserpumpe GARANTIA
- Wasserpumpe Reefe
- Wasserpumpe AquaForte
- Wasserpumpe Maxbear
- Wasserpumpe Tallas
Neueste Bedienungsanleitung fĂĽr -Kategorien-
11 Oktober 2024
8 Oktober 2024
4 Oktober 2024
4 Oktober 2024
2 Oktober 2024
30 September 2024
29 September 2024
27 September 2024
20 September 2024
18 September 2024