WHALE AquaSmart Bedienungsanleitung

WHALE Wasserpumpe AquaSmart

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für WHALE AquaSmart (2 Seiten) in der Kategorie Wasserpumpe. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
Carbon Filter
(Product
Code WF3000)
AQUASMART® WATER SYSTEM
AQUASMART® WATER SYSTEM – TROUBLE SHOOTING
Munster Simms Engineering Ltd.
2 Enterprise Road, Bangor, N. Ireland BT19 7TA Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421
Web: www.whalepumps.com Email: info@whalepumps.com
Ref No: 180.39_v5_0114
Please read carefully before use.
To the Fitter:
Ensure all relevant personnel read and that a copy is passed
on to the end user.
To the User:
Read the user guide overleaf before use of equipment.
SERVICE KITS
Service kits are available from Whale dealers worldwide. To
ensure correct service kits, check Whale website
www.whalepumps.com or contact Whale service desk: Email:
info@whalepumps.com.
REPLACING FILTERS
A pack containing two replacement filters (Product Code
WF3000) is available. Filters will need to be replaced after
filtering 3000 litres (approx. 33 days of normal use). These
filters are not designed for removing bacteria and should not
be used on water supplies of an unknown bacterial quality.
Plug and Hose Assembly
with Dust Cover
(UH0814)
Dust
Cover
Whale Quick
Connect Fitting
(WU1204)
Whale Quick
Connect 12mm
tubing
(WX7112)
Watermaster On
Board Pump
(FP0814)
STANDARD SYSTEM
3-Way
Solenoid
Valve
Whale Quick
Connect
Fitting
(WU1202)
ELECTRIC SYSTEM FOR USE
WITH ONBOARD TANKS
2-Way
Solenoid
Valve
ON-BOARD TANK
ON-BOARD TANK
MANUAL SYSTEM FOR USE
WITH ON-BOARD TANKS
3-Way
Valve
(WU1271)
Take care to retain the o-ring seal when replacing filters
Wall
Socket
FAULT CAUSE SOLUTION
No power to pump
Check power supply
Attach leads/ clean connections
Check tap microswitch is present
Fuse has blown Replace fuse – do not exceed recommended fuse size
Pump doesn’t run
Blockage in pipework Check pipework for kinks
No water getting to pump
Check water tank is not empty
Check filter is not blocked
Check filter is fully submerged in water
Check all connections from tank to inlet of pump are
secure, any leaks will prevent prime.
To test for air leaks hold showerhead underwater and
operate pump. If air bubbles visible coming from the
showerhead then leak is present
Pump runs but no water
appears
Water leak at outlet side of pump Check pipework and fittings for leaks and repair
Check system drain plugs are closed
Water leak at outlet side of pump Check pipework/ fittings for leaks and repair
Check system drain plugs are closed Pump runs but will not switch
off No water Check water supply level
Check and replace filter if clogged
Pump cycles on and off
periodically when all the taps
are closed (Normal with
partially opened tap)
Water leaking at outlet side of pump Check pipework/ fittings for leaks and repair
Check system drain plugs are closed
Pump cycles on and off
excessively when tap(s) open Excessive back pressure Check pipework for kinks and filters etc. are clear
Check shower rose & taps for blockages and repair
Pump drawing air See CAUSE ‘NO water getting in pump’
Noisy Operation Noise created by vibration
Check pump is secured to a solid surface
Check pump body is clear of hard surfaces
Locate away from interfering surfaces
Check pipework is securely supported
Bore of pipework / connections too
small
8.5mm minimum bore recommended for pipework
(Whale Quick Connect 12mm tubing – Product code
WX7112 blue/cold and WX7114 red/hot)
Check for kinks in pipework
Check pipework is not blocked
Power supply to the pump
Check power supply to pump uses correct wire
(2.5mm2) to give full voltage at pump
Check battery is not flat
Pipework/ Connections crushed due to
over tightened jubilee clips Replace damaged connections
Pump too far from water tank Pump should be situated beside inlet/ water tank
Water leaking at outlet side of pump Check pipework fittings for leaks and repair
Check system drain plugs are closed
Low flow
Valves internal filters clogged (if
present)
Remove manual/ electric valve, inspect internal filters
If necessary remove fitting nearest filter
Clean and refit filter and plumbing
OPERATIONS
Onboard Tanks:
If manual valves are included in
this system they must be
positioned appropriately (figs.1 to
4) when switching between the
three functions of the water
system; using an external water
supply, filling the onboard tank, and
using the onboard tank. If electric
valves are included in this system
the three functions are selected
by the three positions of the
switch.
For optimum flow use the
onboard tank.
Priming:
1. Select external water supply
(position the manual valves as
shown in fig.1)
2. Open one hot tap (e.g. kitchen
sink)
3. Place carbon filter fitted to hose,
into water container.
4. Insert plug into wall socket and
close lid to lock plug in place (see
fig.5).
5. Adjust dust cover over water
container opening (please note dust
cover should not be secured to
water container as air must be
allowed to enter container to
replace water being drawn out).
6. Switch on 12 volt DC supply at
main panel isolator switch.
7. Water will flow from the open
tap after filling the water heater.
This can take a few minutes if the
heater is empty. The water may
at first be grey in colour which is
quite normal, the discolouration is
due to harmless media being
flushed out of the new filter
cartridge.
8. When water is flowing smoothly
close hot tap and open cold tap to
expel any remaining air in the
plumbing system
9. The system is now ready for
use. Hose can be inserted into
plug groove (fig.6) to keep filter
off ground while refilling water
container. Keep socket lid shut at
all times when plug is removed
10. When the caravan is
left unattended or water supply
has been allowed to empty, to
prevent the pump running
continuously, turn off at isolating
switch.
WINTERISING
If water is allowed to freeze in the
system, serious damage to the
pipework and pump may occur. To
best avoid this damage, completely
drain the water system.
1. Ensure that both the hot and cold
systems are fully drained by draining
separately. The cold drain plug (if
fitted) is a separate drain plug from
the heater drain plug.
2. Open all the taps (including drain
valve) and allow pump to purge
remaining water from the system,
then turn the pump off
3. Position manual valves (if fitted)
as shown in fig. 4.
4. Remember to leave all tapso
including showers open to avoid any
damage.
AQUASMART® WATER SYSTEM – USER GUIDE
WARNING
When using with an AquaSource system,
do not sleep or leave the vehicle
unattended without turning off the mains
tap.
NOTICE
This product is designed for use with water.
If it is intended for use with any other
liquid, it is the users responsibility to ensure
that the materials are fully compatible with
the liquids to be used and that a system
of safe working practice is applied to
installation, use, and maintenance. A
planned maintenance schedule of regular
inspection is recommended, replacing
components as necessary.
We recommend the pump head be
replaced every 5 years (Product Code
AK1318).
WARRANTY
This Whale product is covered by 2
years warranty.
Please see the enclosed document for
details of our statement of limited
liability.
AQUASMART® WATER SYSTEM – USER GUIDE
PLEASE NOTE: The following
section covers installation of an
AquaSmart® System in a new
vehicle. For retro fitting to an
existing vehicle see separate
leaflet ‘AquaSmart® Water
System – Installation Guide
Existing Vehicle Upgrade’ ref. no.
180.38. Please read the relevant
leaflet before installation.
LOCATION
When looking for a suitable
location to fit the Whale
AquaSmart® System, the
following points should be
considered:
1. The carbon filter should reach
the bottom of the water container.
2. There should be access to the
back of the socket.
3. Ideally, the AquaSmart system
should be fitted close to the water
heater or kitchen sink to avoid long
runs of pipework.
4. Locate the pump in a dry position,
free from submersion and spray, with
adequate ventilation, no more than 2
metres above the water tank.
5. Pump should be mounted
vertically (pump head below
motor).
6. Wire length from the battery to
the pump (via the isolating switch)
should be kept as short as possible
to minimize voltage drop and hence
reduction in pump performance.
INSTALLATION
1. Use template enclosed when fitting
the wall socket.
2. Before installing wall socket, fill
outer groove around flange with
sealant (see fig.7) and secure with
four screws.
3. Ensure correct flow direction
through pump (as indicated on
pump body) and attach pipework
using appropriate adapters (see
fig.8).
4. Pump feet are adjustable to
allow easy installation. Use No.8
stainless steel screws to fasten
the pump to a solid surface
which supports the pump
securely.
5. Connect pump red wire to
+12V DC supply via tap micro-
switches if present, the isolating
switch, and a 5A fuse. Connect
pump black wire to battery earth.
Recommended wire size is
2.5mm2 (AWG 13). Connect the
remaining wire to the pump
running light if present.
Fig.8 Plumbing Guide
Fig.1 Fig.2
Fig.3 Fig.4
Fig.5
Fig.6 Fig.7
Using an
external water
supply
Using the
on-board tank
Filling the
on-board tank
Winterising
Pipe System Used Fitting required
12mm semi-rigid Connect directly using Whale Quick Connect 12mm
fittings
15mm semi-rigid
Use Whale Quick Connect adaptor WU1512 for the
Water Master
Socket and 12mm semi-rigid pipe WX7112 plus
WU1512 x 2 for the pump
3/
8" (10mm) bore flexible hose Use Whale Quick Connect WU1280 x 2 (included in
retail pack) attaching with Stainless Steel hose clips
1/
2" (13mm) bore flexible hose Use Whale Quick Connect adaptor WX1509 for the
Water Master Socket and WU1282 x 2
(included in the retail pack)
for the pump attaching with stainless steel hose clips.


Produktspezifikationen

Marke: WHALE
Kategorie: Wasserpumpe
Modell: AquaSmart

Brauchst du Hilfe?

Wenn Sie Hilfe mit WHALE AquaSmart benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Wasserpumpe WHALE

Bedienungsanleitung Wasserpumpe

Neueste Bedienungsanleitung für -Kategorien-