INTRODUCTION
These instructions contain the speciļ¬cations and
guidelines necessary to install, operate, and
maintain the Modular Pre-Amp/Mixer. The unit
provides connections for up to 4 remote input
modules. The mixer consists of a V-9983 Main
Control Module and a V-9984 Remote Input
Module.
The Modular Pre-Amp Mixer is used with
Valcom distributed ampliļ¬ed one way paging
systems providing additional audio source
inputs.
The V-9985 provides active mixing for 1
balanced microphone and 2 auxiliary inputs.
Also supplied is an additional audio input
(building page) with an override feature. Up to 3
additional Remote Input Modules (V-9984) may
be connected to the Main Control Module. Each
Remote Input Module adds 1 Balanced
Microphone and 1 Auxiliary input.
Applications
Valcom, Inc. Distributed Ampliļ¬ed One-Way
Paging Systems. Refer to Figure 1 for a
block diagram of a typical installation.
Features
Main Control Module V-9983
High impedance auxiliary input
Volume control for auxiliary input
3.5mm stereo mini jack for auxiliary input
Master volume control
Up to (4) four remote mixer modules may be
connected
Separate outputs for Horns and Speake rs
Page port connection (Building Page) with
override option switch
Remote Volume Control Connection
LED Signal Meter
Built in Compressor, option dip switch ā€“
controlled
Power "ON" indicator
Mounts in 3 gang electrical box
MAIN CONTROL MODULE WITH
REMOTE INPUT MODULE
Remote Input Module V-9984
Balanced microphone
XLR Mic. Connection
Phantom power for electret microphones
(Switch controlled)
Phantom power ā€œONā€ indicator
High impedance auxiliary input
Volume control for auxiliary input
3.5mm stereo mini jack for auxiliary input
Power "ON" indicator
Mounts in single gang electrical box
Connects to Main Control Module with 2 pair
24AWG station cable
Screw terminals for distribution connections
Dimensions
Main Control Module
5"W x 4.25"H x 2ā€D
(12.7cm W x 10.8cm D x 5.08cm H)
4 lbs. (1.5Kg)
Remote Input Module
1.64W x 4.25"H x 2ā€D
(4.17cm W x 10.8cm D x 5.08cm H)
lbs. (0.1Kg).25
947285
2
Speciļ¬cations
Outputs
Main Output: - dBm nominal, 100 Ohms 10
Frequency Response: 2Hz to 20kHz Ā± 1dB
Horn Output: - dBm nominal, 100 Ohms 10
Frequency Response 20Hz to 20kHz Ā± 1dB
(12 dB/Octave High pass at 300Hz)
Tone Controls
Bass (50 Hz) boost or cut up to 12 dB
Treble (10 kHz) boost or cut up to 12 dB
Signal to Noise
-80 dB from maximum output
Auxiliary Input Sensitivity
10mV RMS for -10 dBm output
Input Impedance: >40 kā„¦
Bldg Page Input Sensitivity
30mV RMS for -10 dBm output
Input Impedance: >4 kā„¦ (balanced input)
Signal Meter
-10 dBm output lights ļ¬rst 5 LED's
3 dB per LED segment
Compression Ratio: 2.5 ļ¬xed
Attack: 1.5 Ms
Release: 0.3 seconds
Remote Volume Control
10 kā„¦ linear taper (gives audio taper)
One pair connection
Power Requirements
Voltage: 24VDC
Current: 50mA
Remote Module
Connections: 1 pair audio, 1 pair 24VDC
(From main control module)
Input Impedance: >4 kā„¦ (balanced)
Maximum Input: 1Vrms
Microphone Input
40uVRMS (-10 dBm out) Input Sensitivity:
Max Input: 30mVRMS
Input Impedance: 3.5 kā„¦ Balanced
Signal to Noise
-65 dB from max output
Phantom Power
24VDC with 2.2 kā„¦
Auxiliary Input
Sensitivity
10mVRMS for -10 dBm output
Max Input: 1.4VRMS
Input Impedance: > 40 kā„¦
Environment
Temperature 0 to 50Ā°C
Humidity 0 to 85% non-precipitating
INSTALLATION
Figure 1 shows volume control locations,
microphone and auxiliary input connections.
Figure 2 shows output terminal strips and
switches on the back of the mixer. Figure 3
shows a typical connecting arrangement. The
V-9985 contains a Main Mixer Module and 1
Remote Module. Three additional remote
modules may be connected to the main mixer
module. Figure 4 shows other feature
connections. Figure 5 shows Remote Input
Module, Speaker and Power Connections.
All connections should be made to the mixer and
double-checked prior to connecting DC power.
Connect the microphone to balanced XLR cables
and the microphone XLR connector on the
Remote Input Module. If the microphone is a
condenser type it will require Phantom Power.
Turn ā€œONā€ the Phantom Power Switch located on
the Remote Module using a small scribe or paper
clip. The Phantom Power LED will illuminate.
The microphone volume control is located on the
remote module. Other sources such as CD and
MP3 players, tuners, and computer sound cards
may be connected to the auxiliary inputs located
on the remote and main modules. Volume
controls for the auxiliary inputs are located on the
remote input and main control module.
An additional audio input is available with a
volume control located on the PC board for
connection to a low level audio source such as a
telephone page port o Valcom One-Way Page r
Control. An option dip switch located on the PC
board enables the input to override the
microphone and auxiliary inputs.
A compressor is available to even out a userā€™s
voice to compensate for poor microphone or
vocal technique and allow more microphone gain
before feedback. All auxiliary and microphone
inputs are routed through the compressor when
enabled. An option dip switch located on the PC
board enables the compressor.
947285
3
A connection is provided to a remote volume add
control. This is a 2 wire connection using a 10K
Ohm linear potentiometer.
Speaker Connections
Connect Tip and Ring of Valcom Amplifed
Speakers to the output screw terminals located
on the Main Mixer Module. Connect Tip and Ring
of Valcom Ampliļ¬ed Paging Horns to horn audio
output screw terminals.
When setting the system up, it is recommended
that the master gain control be set 2/3 and aux
volume controls be set to 1/4.
OPERATION
The V-9985, Four Channel Pre-Amp/Mixer
actively mixes any signals present on the inputs.
Each input is equipped with its own volume
control to allow blending of the input sources.
The unit also has a master volume control to
allow a volume level adjustment of all mixed
signals. Bass and treble controls allow up to
12dB of boost or cut at 50Hz and 10kHz.
An audio input is available on the main control
module allowing connection of a low level signal
that will override all other inputs. An option dip
switch controls the override feature.
The integrated compressor feature is controlled
by an option dip switch. Microphone and
auxiliary inputs are routed through the
compressor when the compressor is active.
Two outputs are provided by the V-9985 modular
mixer.
An output to drive full range speakers
An output to drive limited range paging horns
TECHNICAL ASSISTANCE
When trouble is reported, verify there are no
broken connections. Assistance in
troubleshooting is available from the factory.
Call (540) 563-2000 and press 1 for
Technical S ort, or visit our website at upp
http://www.valcom.com.
Valcom equipment is not ļ¬eld repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating company
name, address, phone number, contact person
and nature of the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from
the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty
period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus
parts and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any anticipated
proļ¬ts, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product.
This warranty speciļ¬cally excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notiļ¬ed
immediately. Claims for such damage should be ļ¬led with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019-5056
Phone: (540) 563-2000
FAX: (540) 362-9800


Produktspezifikationen

Marke: Valcom
Kategorie: Mischpult
Modell: V-9984

Brauchst du Hilfe?

Wenn Sie Hilfe mit Valcom V-9984 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Mischpult Valcom

Bedienungsanleitung Mischpult

Neueste Bedienungsanleitung fĆ¼r -Kategorien-