Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. All rights reserved.
1
Metered Rack PDU
PDUMV15-24, PDUMV15-36
(Series Number: AG-00E1)
PDUMV20-24, PDUMV20-36, PDUMV20-72
PDUMV15-72, PDUV20-72
(Series Number: AG-00DD)
Important Safety Instructions 2
Installation 3
Features 4
Warranty & Product Registration 5
Español 6
Français 11
WARRANTY REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR®
surge protector in our monthly drawing!
tripplite.com/warranty
20-09-043-933381.indb 1
20-09-043-933381.indb 1
20-09-043-933381.indb 1
20-09-043-933381.indb 120-09-043-933381.indb 1 10/9/2020 10:00:34 AM
10/9/2020 10:00:34 AM
10/9/2020 10:00:34 AM
10/9/2020 10:00:34 AM10/9/2020 10:00:34 AM

SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed
during the installation, operation and storage of this product. Failure to
heed these instructions and warnings may affect the product warranty.
Important Safety Instructions
2
• The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line
noise protection for connected equipment.
• The PDU is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
• Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
• The PDU must be installed by a qualified technician only.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
• Connect the PDU to an outlet that is in accordance with your local building codes and that
is adequately protected against excess currents, short circuits and earth faults.
• The electrical outlets supplying power to the equipment should be installed near the
equipment and easily accessible.
• Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
• Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
• Never attempt to install electrical equipment during a thunderstorm.
• Individual equipment connected to the PDU should not draw more current than the
individual PDU’s outlet’s rating.
• The total load connected to the PDU must not exceed the maximum load rating for the
PDU.
• Do not attempt to modify the PDU, input plugs or power cables.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-
serviceable parts inside.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
20-09-043-933381.indb 2
20-09-043-933381.indb 2
20-09-043-933381.indb 2
20-09-043-933381.indb 220-09-043-933381.indb 2 10/9/2020 10:00:34 AM
10/9/2020 10:00:34 AM
10/9/2020 10:00:34 AM
10/9/2020 10:00:34 AM10/9/2020 10:00:34 AM

2
1B
1A
3
4
5
PDUMV15-24
and PDUMV15-36
PDUMV20-24, PDUMV20-36
and PDUMV20-72
PDUMV20-24, PDUMV20-36
and PDUMV20-72
1C
3
Installation
3
1A
Zero U Rack Configuration. Attach the two mounting
clips supplied with the PDU to the rack enclosure using
the included hardware. The mounting clips should be
attached along a vertical plane at equidistant points
which roughly correspond to the center and ends of the
PDU. The exact mounting configuration may vary
depending on the rack and enclosure. If possible, use
pre-existing mounting points within the enclosure.
1B
Wall or Under-Counter Configuration. Attach the two
mounting clips supplied with the PDU to a wall or
similar flat, secure surface using the included hardware.
The mounting clips should be attached along a vertical
or horizontal plane at equidistant points which roughly
correspond to the center and ends of the PDU. If
possible, use pre-existing mounting points. WARNING:
Do not attempt to mount the PDU with the outlets
facing downward; the mounting clips are not
designed to support the weight of the PDU in that
manner.
1C
Zero U Rack Configuration. For toolless mounting:
Position the PDU as desired in the rack enclosure, align
the buttons with the rack mounting slots and slide the
PDU into position.
Note: Mounting buttons come preinstalled with select
models.
Note: Regardless of configuration, the user must
determine the fitness of hardware and procedures
before mounting. The PDU and included hardware are
designed for common rack and rack enclosure types
and may not be appropriate for all applications.
2
Attach the PDU to the mounting clips. Using an
assistant, place a rear corner of the PDU on the inside
edge of the mounting clips, pivot the PDU toward the
alternate inside edge and snap into place.
3
Attach the input plug of the PDU to a grounded
outlet. Insert the plug directly into a grounded outlet
that does not share a circuit with a heavy electrical
load (such as an air conditioner or refrigerator).
4
Attach equipment to the PDU. Do not exceed the
load rating of the PDU. The total electrical current used
by the PDU will be displayed on the digital meter in
amperes.
5
Optional Installation (Models PDUMV20-24,
PDUMV20-36 and PDUMV20-72). The PDU includes
an adapter that converts the L5-20P input plug to a
5-20P input plug. The adapter is optional; the PDU will
work properly without connecting the adapter.
20-09-043-933381.indb 3
20-09-043-933381.indb 3
20-09-043-933381.indb 3
20-09-043-933381.indb 320-09-043-933381.indb 3 10/9/2020 10:00:35 AM
10/9/2020 10:00:35 AM
10/9/2020 10:00:35 AM
10/9/2020 10:00:35 AM10/9/2020 10:00:35 AM
Produktspezifikationen
Marke: | Tripp Lite |
Kategorie: | Anbaustein |
Modell: | PDUMV15-72 |
Breite: | 38.1 mm |
Tiefe: | 41.7 mm |
Gewicht: | 2790 g |
Produktfarbe: | Schwarz |
Höhe: | 1840.7 mm |
Stecker: | NEMA L5-15P |
AC Eingangsfrequenz: | 50/60 Hz |
Verpackungsbreite: | 168.9 mm |
Verpackungstiefe: | 1925.1 mm |
Verpackungshöhe: | 61 mm |
Paketgewicht: | 3480 g |
Montage: | Senkrecht |
Zertifizierung: | UL60950-1 (USA), CSA60950-1, NOM |
Display: | LED |
Ursprungsland: | China |
Kabellänge: | 4.6 m |
Betriebsanleitung: | Ja |
Gehäusematerial: | Aluminium |
LED-Anzeigen: | Ja |
Temperaturbereich bei Lagerung: | 5 - 95 °C |
Anzahl Produkte pro Versandkarton: | 6 StĂĽck(e) |
Gewicht Versandkarton: | 22500 g |
Länge des Versandkartons: | 1944.9 mm |
Breite des Versandkartons: | 359.9 mm |
Höhe des Versandkartons: | 214.9 mm |
Nachhaltigkeitszertifikate: | RoHS |
Rackmontageset: | Ja |
Höhe bei Betrieb: | 0 - 3000 m |
Hauptkarton GTIN (EAN/UPC): | 10037332255836 |
Anzahl der AC-Ausgänge: | 36 AC-Ausgänge |
AC-Steckertypen: | NEMA 5–15R |
Stromstärke (maximal): | 15 A |
Nominale Eingang Spannung: | 100-127 V |
Nominale Ausgang Spannung: | 100-127 V |
Rack-Kapazität: | 0U |
PDU-Typen: | Messgerät |
Ladekapazität: | 1800 VA |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Tripp Lite PDUMV15-72 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Anbaustein Tripp Lite

28 März 2024

27 März 2024

21 März 2024

7 März 2024

27 Februar 2024

20 Februar 2024

12 Februar 2024

7 Februar 2024

29 Januar 2024

16 Januar 2024
Bedienungsanleitung Anbaustein
- Anbaustein Hama
- Anbaustein Nedis
- Anbaustein Philips
- Anbaustein Brennenstuhl
- Anbaustein REV
- Anbaustein Ewent
- Anbaustein Icy Box
- Anbaustein Bachmann
- Anbaustein Kopp
- Anbaustein Kindermann
- Anbaustein Digitus
- Anbaustein DataVideo
- Anbaustein APC
- Anbaustein CyberPower
- Anbaustein EnerGenie
- Anbaustein Steren
- Anbaustein AMX
- Anbaustein EVOline
- Anbaustein StarTech.com
- Anbaustein Panduit
- Anbaustein Legrand
- Anbaustein ATen
- Anbaustein Lanberg
- Anbaustein Oehlbach
- Anbaustein Middle Atlantic
- Anbaustein Geist
- Anbaustein Anton/Bauer
- Anbaustein Adam Hall
Neueste Bedienungsanleitung fĂĽr -Kategorien-

20 Juni 2024

17 Juni 2024

24 Mai 2024

24 Mai 2024

23 Mai 2024

17 Mai 2024

9 Mai 2024

7 Mai 2024

6 Mai 2024

4 Mai 2024