Owner’s Manual
PDUMH15NET2LX/PDUMH20NET2LX
Switched Rack PDU
120V, 50/60 Hz AC Input and Output
(AG-0091, AG-0092)
Important Safety Instructions 2
Installation 3
Features 5
Configuration and Operation 7
Technical Support 7
Warranty and Product Registration 8
Español 9
Français 17
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2017 Tripp Lite. All rights reserved.
17-02-374-9336CB.indb 1 6/2/2017 2:14:57 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation, and storage of this
product. Failure to heed these instructions and warnings may
affect the product warranty.
• The PDU provides the convenience of multiple outlets, but DOES NOT provide surge
or line noise protection for connected equipment.
• The PDU is designed for indoor use only, in a controlled environment, away from
excess moisture, temperature extremes, conductive contaminants, dust or direct
sunlight.
• Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
• The PDU must be installed by a qualified technician only.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Install in accordance with National Electrical Code standards. Be sure to use the
proper overcurrent protection for the installation, in accordance with the plug/
equipment rating.
• Connect the PDU to an outlet that is in accordance with your local building codes
and that is adequately protected against excess currents, short circuits and earth
faults.
• The electrical outlets supplying power to the equipment should be installed near the
equipment and easily accessible.
• Do not connect the PDU to an ungrounded outlet or to extension cords or adapters
that eliminate the connection to ground.
• Be sure to provide a local disconnect device on any models that are permanently
installed without a plug that is easily accessible.
• Never attempt to install electrical equipment during a thunderstorm.
• Individual equipment connected to the PDU should not draw more current than the
individual PDU’s outlet’s rating.
• The total load connected to the PDU must not exceed the maximum load rating for
the PDU.
• Do not attempt to modify the PDU, input plugs or power cables.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-
serviceable parts inside.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Use of this equipment in life support applications where failure of this equipment
can reasonably be expected to cause the failure of the life support equipment or to
significantly affect its safety or effectiveness is not recommended.
17-02-374-9336CB.indb 2 6/2/2017 2:14:57 PM
1-1
1-2
1-3
C
B
A
C
C
C
C
A
A
B
B
1-4
A
B
C
3
Installation
Mounting the PDU
The PDU supports four primary mounting configurations: 1U Rack, 0U Rack (Vertical),
Wall and Under-Counter.
Note: Regardless of configuration, the user must determine the fitness of hardware and procedures before
mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may
not be appropriate for all applications. Exact mounting configurations may vary. Screws for attaching the
mounting brackets and cord retention shelf to the PDU are included. Use only the screws supplied by the
manufacturer or their exact equivalent (#6-32, 3/16" flat head).
1-1 1U Rack Mounting: Use 4 screws
A to attach each of the 2
mounting brackets B to the PDU
as shown. Mount the PDU in the
rack by inserting 4 user-supplied
screws C through the mounting
brackets B and into the mounting
holes of the rack rails.
1-2 0U Rack Mounting: Use 4 screws
A to attach each of the 2
mounting brackets B to the PDU
as shown. Mount the PDU
vertically by inserting 2 or more
user-supplied screws C through
the mounting brackets B and into
mounting points in the rack or
rack enclosure.
1-3 Wall Mounting: Use 4 screws A
to attach each of the 2 mounting
brackets B to the PDU as shown.
Mount the PDU to the wall by
inserting 2 or more user-supplied
screws C through the mounting
brackets B and into secure
mounting points.
1-4 Under-Counter Mounting: Use 4
screws A to attach each of the 2
mounting brackets B to the PDU
as shown. Mount the PDU under
the counter by inserting 2 or more
user-supplied screws C through
the mounting brackets B and into
secure mounting points.
17-02-374-9336CB.indb 3 6/2/2017 2:15:00 PM

Produktspezifikationen

Marke: Tripp Lite
Kategorie: Anbaustein
Modell: PDUMH15NET2LX
Breite: 444.5 mm
Tiefe: 108 mm
Gewicht: 2360 g
Produktfarbe: Schwarz
Höhe: 44.4 mm
Stecker: NEMA 5–15P
AC Eingangsfrequenz: 50 - 60 Hz
Relative Luftfeuchtigkeit in Betrieb: 5 - 95 %
Verpackungsbreite: 300 mm
Verpackungstiefe: 519.9 mm
Verpackungshöhe: 54.1 mm
Paketgewicht: 3140 g
Montage: Horizontal
UnterstĂĽtzte Netzwerkprotokolle: IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Zertifizierung: UL 60950-1 (USA). CAN/CSA-C22.2 NO. 60950-1 (Canada), Class A Part 15 (Emissions), NOM\n(Mexico), TAA Compliant
Display: LCD
Ursprungsland: Taiwan
Typ: Einphasig
Kabellänge: 3.66 m
Betriebsanleitung: Ja
Gehäusematerial: Metall
LED-Anzeigen: Ja
Temperaturbereich bei Lagerung: -15 - 50 °C
Ein-/Ausschalter: Ja
Anzahl Produkte pro Versandkarton: 1 StĂĽck(e)
Abmessungen (BxTxH): 444 x 108 x 44.4 mm
Nachhaltigkeitszertifikate: RoHS
Verpackungsabmessungen (BxTxH): 300 x 520 x 54 mm
Max. Leistung: 1520 W
Höhe bei Betrieb: 0 - 3000 m
Temperatur Betriebsumgebung: 5 - 122 °F
Anzahl der AC-Ausgänge: 8 AC-Ausgänge
AC-Steckertypen: NEMA 5–15R
Stromstärke (maximal): 15 A
Nominale Eingang Spannung: 100-127 V
Nominale Ausgang Spannung: 100-127 V
Rack-Kapazität: 1U
PDU-Typen: Geändert
Ausgabekontrolle: Lock-out, Recycle, Turn off, Turn on

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tripp Lite PDUMH15NET2LX benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Anbaustein Tripp Lite

Bedienungsanleitung Anbaustein

Neueste Bedienungsanleitung fĂĽr -Kategorien-