Thank you
We would like to thank you cordially for choosing this sE microphone! This manual contains some
important instructions for setting up and operating your new equipment. Please take a few
minutes to read the instructions below carefully. We hope you will enjoy working with it as much
as we enjoyed designing and building it for you.
Most Sincerely,
Your sE Team
Brief Description
The sE2300 is the latest multi-pattern version of the fan-favorite 2200 condenser that put sE
Electronics on the map many years ago with its smooth, polished sound for vocals, voiceovers,
and numerous instrumental applications. Like its well-known predecessors, the sE23 is a high-00
quality condenser microphone intended for a wide range of studio applications, from vocals and
spoken word to acoustic instruments to drums d beyond. Thanks to its hand-crafted large-an
diaphragm true condenser capsule, shielded custom transformer and class-A circuitry (no ICs
here!) it delivers pristine, flattering sound quality, exceptionally low noise, and an even, well-
balanced frequency response.
The electronics and the switchable attenuation pads ensure a high dynamic range, with high
sound pressure level (SPL) handling capability and extremely low-noise components. The
switchable low-cut filters eliminate rumble or footfall noise, and can also compensate for an
excess of bass frequencies caused by the proximity effect. This enables the sE2300 to close-mic
many instruments including electric guitar speaker cabinets, brass instruments and drums. The
three switchable polar patterns also all for the tailoring of the balance between direct and ow
ambient sound, providing many options for various recording techniques.
Reliable operation even in demanding applications in difficult environments is ensured by the
roadworthy all-metal design, robust construction, and high-quality manufacturing standards.
What’s in the box
Your packaging should contain the follow items. If anything is missing, please contact your sE
Electronics dealer and let them know.
• sE23 microphone 00
• sE Isolation Pack (shock mount, pop filter)
• thread adapt er
Controls
The sE23 features a switch for the attenuation pads a switch for the low-cut filters, and a 00 ,
switch for the polar pattern selection.
Attenuation Switch
The is located on the front-left side of the Attenuation Switch
microphone. When switched on, the incoming signal is reduced by
either 10 or 20 dB for capturing of loud instruments and/or close-
miking without distortion. Using the switch also helps prevent
3
overloading the input stage of recording interfaces, mixing desks and microphone preamps.
Low-Cut Switch
The Low-Cut Switch is located on the front-right side of the microphone,
and inserts a low-cut filter at 80Hz (left position) or 160Hz (right
position). The switch’s center position removes the filter for a flat
frequency response. Wind noise, plosives, footfall noise or rumble might
affect the recorded signal, so enabling the low-cut filters reduces such
unwanted noise and prevents distortion. Additionally, the -cut filterlow s
also minimize the proximity effect when recording sound sources at a
very short distance.
Pattern Switch
The 3-position Pattern Switch is located on the rear side of the
microphone, and allows the sE2300’s polar pattern to be changed from
omnidirectional to cardioid to figure-eight. This allows for great control
over the balance between direct and ambient sound.
Powering
To ensure proper operation, the microphone requires a phantom power source providing 48 Volts
according to IEC 61938.
Risk of damage
Do not connect the microphone to any power supply other than a phantom
power source (input with phantom power or external IEC standard phantom
power supply) with a floating connector, using a balanced cable with studio
grade connectors to IEC 268-12 only. This is the only way to ensure safe
and reliable operation.
Safety and maintenance
Risk of damage
Please make sure that the piece of equipment to which your microphone
will be connected fulfils the safety regulations enforced in your country and
is fitted with a ground lead.
Cleaning the microphone
After every use, clean the microphone with a dry, soft cloth tissue and store it in a solid case or a
zipper pouch.
Technical Specifications
Capsule
Hand-crafted 1“ true condenser capsule
Polar patterns
Cardioid, Omni-directional, Figure-8
Frequency range
20 20,000 Hz –


Produktspezifikationen

Marke: SE Electronics
Kategorie: Mikrofon
Modell: sE2300

Brauchst du Hilfe?

Wenn Sie Hilfe mit SE Electronics sE2300 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Mikrofon SE Electronics

Bedienungsanleitung Mikrofon

Neueste Bedienungsanleitung für -Kategorien-