Thank you
Thank you for choosing an sE microphone! In addition to some basic safety precautions, this manual
includes details and specifications that we hope will assist you in getting the most out of your Gemini II.
Please take a few minutes to read through it.
Capturing great audio is our passion. We sincerely hope you’ll enjoy the sound of this mic as much as we
enjoyed designing and building it for you.
Happy Tracking,
The sE Team
Brief Description
The Gemini II is our homage to the classic era of valve microphones. We wanted to create something
uniquely modern and versatile, while preserving the larger-than-life sonic legacy that defined tube mics of
decades past. This large-diaphragm cardioid condenser has that signature warmth and weight to its sound,
courtesy of a 12AX7 input valve, while boasting an unattenuated presence range. Where most microphones
have an output transformer, we have instead added a 12AU7 valve, giving the Gemini II the pristine top end
that you’d expect from an expensive solid-state mic. Vocal tones recorded with the Gemini II sound polished,
and ready to take front and center in your mix.
The Gemini II isn’t only for vocals, though. We’ve equipped it with a switchable low cut filter, as well as a
switchable -10dB pad, allowing it to shine on a variety of sources. In the drum room, on an acoustic guitar,
capturing the boom of timpani, or the intimacy of a cello, the Gemini II will not let you down.
All sE microphones are built by hand at our headquarters in Shanghai. We take pride in the attention to detail
under which our products are crafted, therefore the entirety of manufacturing is done in our own facilities. We
also test and measure the tubes for each Gemini II to ensure optimal performance.
What’s in the box
Your Gemini II includes a custom flight case to safely transport the microphone and its necessary
accessories. If anything is missing, please contact your sE Electronics dealer for assistance.
• Gemini II microphone
• Custom shock-mount
• 8-pin cable
• Power supply
• IEC power cable
Controls
The Gemini II features both an Attenuation Switch and a Low-Cut Switch.
Attenuation Switch
The is located on the front-left side of the microphone. When
Attenuation
Attenuation
Attenuation
Attenuation Attenuation Switch
Switch
Switch
SwitchSwitch
engaged, the incoming signal is reduced by , helping prevent signal distortion and 10dB
preamplifier clipping when capturing audio at close proximity and/or high sound
pressure levels.
3
Low-Cut Switch
The is located on the front-right side of the microphone, inserting a low-cut
Low
Low
Low
LowLow-Cut Switc
-Cut Switc
-Cut Switc
-Cut Switc-Cut Switch
h
h
hh
filter at 0Hz when engaged. When switched to the left, the filter is removed for a flat 15
frequency response. This low-cut switch is useful for reducing wind noise, plosives, footfall
noise or rumble that ght adversely affect the recorded signal. Additionally, e low-cut mi th
filter will minimize the proximity effect when - placing the microphone a “close miking,” i.e.
very short distance from the source.
Powering
The included floor box contains the outboard power supply for the Gemini II . No
No
No
No No phantom
phantom
phantom
phantom phantom power
power
power
power power is
is
is
is is required
required
required
requiredrequired
from an interface or microphone preamplifier.
Before powering on, connect all required cables (IEC to power, XLR to preamplifier or interface, and 8-pin
cable from floor box to microphone). Then turn the power on via the switch on the back of the Gemini II floor
box.
For best performance, we recommend allowing approximately 15 minutes of “warm up” time before
recording. This allows the tubes within the Gemini II to heat up and stabilize and reduces the risk of unwanted
noise or distortion on your recordings.
Risk of damage
Do not connect the microphone to any power supply other than the included Gemini II
power supply. Do no
Do no
Do no
Do noDo not apply phantom voltage
t apply phantom voltage
t apply phantom voltage
t apply phantom voltaget apply phantom voltage (+48VDC) from an external interface or
preamplifier. This is the only way to ensure safe and reliable operati . on
Safety and maintenance
Risk of damage
Please make sure that the piece of equipment to which your microphone and PSU will
be connected fulfils the safety regulations enforced in your country and is fitted with a
ground lead.
Cleaning the microphone
The microphone should only be cleaned with a dry, soft cloth. It is best stored in the supplied wooden
presentation box.


Produktspezifikationen

Marke: SE Electronics
Kategorie: Mikrofon
Modell: Gemini II

Brauchst du Hilfe?

Wenn Sie Hilfe mit SE Electronics Gemini II benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Mikrofon SE Electronics

Bedienungsanleitung Mikrofon

Neueste Bedienungsanleitung fĂĽr -Kategorien-