5. Select a depth of penetration by rotating the top portion of the
depth adjustable cap until the number matched to the window.
Settings are based on skin type.”1,2” are for soft or thin skin. “3,4”
are for average skin. “5,6” are for thick or calloused skin.
6.
Hold the hub in one hand and pull on the plunger in the
other hand. The device will be cocked. Release the
plunger; it will go back to its original position near the hub.
19-A2-LDE107-A
Instructions for the LD-E1 Lancing Device
Special Features
Cleaning
Warranty
Cautions
Instructions for use
- Be careful not to be pricked by the lancet whenever the depth adjustable
cap is open with lancet loaded.
- The lancing device is intended for single user. To avoid exposure to
contaminants, do not use the lancing device on multiple users.
- For safety and to prevent cross-contamination, always discard used
disposable lancets in an appropriate puncture-proof or biohazard container.
- Except follow the user’s instructions, please do not disassemble the lancing
device under any condition.
- The lancing device contains some small parts which could result in choking
hazard for children. Please store it properly and keep away from young
children.
- When the cap is close and the lancing device is loaded, the safety switch
will lock the cap.Please press the release button before opening the cap.
- Safety Switch design: when the depth adjustable cap is open, the trigger
will be relieved automatically which prevents users from being pricked if you
are not intended to start the test. You can eject the used disposable lancet
on one hand operation by pushing the plunger with your thumb at this status.
(Please refer to the figure of step 9.)
- When the cap is close, it will lock the lancet eject function and prevent the
lancet from being removed when you are intended to start the test.
- Stable and sophisticated structure design ensures this lancing device create
nearly no vibration, so that the pricking with the lancet becomes steady and
no pain feeling. It lowers the psychological pressure of users very much and
let people recover the test frequencies which recommended by HCPs.
- A stylish, slim and ergonomic design is very convenient and user friendly for
people to get adapt to it even for the use of the first time.
- Clear indication for depth penetration (numeric display): easy to read and
adjust for users.
Please clean your hand with soap and warm water; dry them thoroughly.Warming your hands will help in obtaining a blood sample.
Follow the steps below. Each step corresponds to the number illustrations.
1. Hold the depth adjustable cap in one hand and hold
hub in the other hand, twist off the depth adjustable
cap.
2. Insert a new disposable lancet firmly into the lancet
holder.
4. Replace the depth
adjustable cap.
7. Place the lancing device against the soft side into fingertip,
press the release button.
The better puncture sites are on
the middle or ring fingers.
8. Pull off the depth adjustable cap. Stick the lancet tip into
the protective cover without touching the used disposable
lancet.
9. Hold the hub with one hand and push the plunger by
thumb to eject the used disposable lancet.
10.Discard the disposable lancet into a proper
puncture-proof or biohazard container.
11. Replace the depth
adjustable cap after
finishing the test.
3. Twist off and set aside
the protective cover of
the disposable lancet.
2. Palm or forearm for alternative site test(Optional)
(1)Choose clear cap and follow step 1 to step 4.
(2)Massage the puncture area of palm or forearm for few seconds.
(3)Immediately after massaging the puncture area, press and hold the
lancing device with the clear cap.
(4)Press the release button.
(5)Keep holding the lancing device against palm or forearm and gradually
raise the pressure for a few seconds until the blood sample is sufficient.
(6)Follow step 8-10 to discard the used disposable lancet.
Use a clean damp cloth to wipe the outside of the lancing device. To avoid rusting the internal spring, do not submerge the device in water or wash the
device in the water.Before using the lancing device, please use disinfectants to clean front cap of lancing device which contacts the skin directly to avoid
bacterial, viral infection or repeated cross-infection.
Releasing button
Pressing for
a few seconds
Ergonomic design enable the comfortable press on finger
and lower the psychological stress before activate it.
Big window to show the penetration depth with numeric
display which is easy for the user to read.
Patented safety switch design:
when the cap is close, it allows only load
but lock the function of lancet ejection.
When cap is open,it allows lancet ejection
but release the trigger automatically to
prevent accidental pricking.
Big release button, comfortable
and easy to operate.
Patented feature of lancet
ejection by one thumb pushing
with only one hand operation.
The disposable lancet
Release buttonDepth adjustable cap
Lancet holder Hub Plunger
The protective cover
Clear cap
(Optional)
1. Fingertip
1
2
3456
7811
10
9
- Intended Use: The lancing device is intended for use by a single person with
the lancet puncturing through the skin for collecting blood sample.
MDSS GmbH
Schiffgroben 41, 30175 Hannover, Germany
MEDIFUN CORPORATION
No.8, Shuyi Rd., South Dist., Taichung City, 40241, Taiwan (R.O.C.)
 Rossmax Swiss GmbH, 9435 Heerbrugg, Switzerland,
www.rossmax.com
- Medifun warrants that your lancing device is free from defects for five years from the date of purchase. Any defects in materials or caused by
workmanship will get repaired or get a new replaced on of this device free of charge.
This warranty does not apply to the condition that the lancing device has been misused, tampered or abused in any way. This warranty will provide you
legal rights under law.
- If there is any severe incident in relation to the device, it should be reported to the manufacturer and the competent authority of the Member State in
which the user and/or patient is established.
Produktspezifikationen
Marke: | Rossmax |
Kategorie: | Messung |
Modell: | LD-E1 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Rossmax LD-E1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Rossmax
21 Juni 2024
16 Juni 2024
15 Juni 2024
15 Juni 2024
15 Juni 2024
14 Juni 2024
14 Juni 2024
Bedienungsanleitung Messung
- Messung REV
- Messung Voltcraft
- Messung Bosch
- Messung Laserliner
- Messung Velleman
- Messung Bresser
- Messung König
- Messung TFA
- Messung Black And Decker
- Messung Trotec
- Messung DeWalt
- Messung Megasat
- Messung Smartwares
- Messung Garmin
- Messung GOCLEVER
- Messung Workzone
- Messung Amprobe
- Messung Meec Tools
- Messung Metrix
- Messung Yato
- Messung Hager
- Messung Kyoritsu
- Messung GW Instek
- Messung Milwaukee
- Messung Eizo
- Messung Testo
- Messung Victron Energy
- Messung Peak
- Messung KĂĽbler
- Messung Carrier
- Messung Lund
- Messung Testboy
- Messung Fantini Cosmi
- Messung Multimetrix
- Messung Extech
- Messung BENNING
- Messung Fluke
- Messung FLIR
- Messung Vemer
- Messung Ridgid
- Messung Stabila
- Messung Entes
- Messung Gossen Metrawatt
- Messung Hameg
- Messung Megger
- Messung PCE Instruments
- Messung Sanwa
- Messung Sonel
- Messung Uni-T
- Messung Wachendorff
- Messung TFA Dostmann
- Messung Vimar
- Messung Owon
- Messung PeakTech
- Messung Dahua Technology
- Messung YSI
- Messung Aluratek
- Messung Eltako
- Messung H-Tronic
- Messung HT Instruments
- Messung Beha-Amprobe
- Messung Chauvin Arnoux
- Messung Werma
- Messung Eastron
- Messung Pancontrol
- Messung X-Rite
- Messung CESYS
- Messung Trumeter
- Messung ORNO
- Messung TDE Instruments
- Messung Zircon
- Messung Adwa
- Messung Greisinger
- Messung Qubino
- Messung WeidmĂĽller
- Messung CEM
- Messung Klein Tools
- Messung Daytronic
- Messung AREXX
- Messung Delta Ohm
- Messung Camille Bauer
- Messung Rigel Medical
- Messung Seaward
- Messung AstroAI
- Messung P3 International
- Messung Seek Thermal
- Messung Fixpoint
Neueste Bedienungsanleitung fĂĽr -Kategorien-
4 August 2024
24 Juni 2024
24 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
22 Juni 2024
21 Juni 2024
21 Juni 2024