Seite 1/3
Correct moving orientation Detection Angle
9m Max 120°
It can identify day and night automatically. And the working light can be chosen freely and make it work at
night and not work in the day time.
Illuminated time can be adjusted according to the customer’s desire.
Mini shell (57mm*44.5mm*28mm)
Sense LED: when it detect sensing signal, the LED flash.
Power source: 220-240V/AC
Power frequency: 50Hz
Rated load: 50W Max.
Detection range: 9m Max.
Time setting: Min: <5sec
Max:8min±1min(adjustable)
Detection angle: 120°
Light-control: <10~2000LUX (adjustable)
Working humidity: <93%RH
Working temperature: -25~+45℃
Power consumption: <0.5W
Installation height: 0.7~2m
Black White
Summary
Characters
Specifications
Sensor information
RLX-1201
Infrared Sensor
Instruction
The product is a new saving-energy switch adopting the good sensitivity
detector, integrated circuit and SMT. It gathers automatic, convenient, safe,
saving-energy and practical functions. The wide detection field is made up of up
and down, left and right service field. It works by receiving human motion
infrared rays. When one enters the detection fields, it can start the load at once
and identify day and night automatically;It can be used with various types of
lamps and lanterns .
Unit:mm
IP:44
After installation, before switching on power turn the time anti-clockwise to min;
Switch on power, after 30sec the sensor enter stable working state;
After the load turn off, sense it, the load should turn on, and under the condition that no continual sensing
signal, the load should turn off within 5sec;
When the light-control knob anti-clockwise set to the min, if you test the unit in the daytime, sense it, the load
should not work. Cover the detection window with opaque object (simulate night light) and sense it, the load
should turn on;
If all are normal, according to your require you can turn the time knob to set the lighting time and turn the
light-control knob to select working light.
Note:please don’t adjust the two functional buttons to excess. That is because the two
functional buttons were connected to the components directly, there is a small stopper in
each of the two components, when you adjust the buttons from start to end, the excessive
turn will damage the stopperand lead to the 360°non-stop turn around.The adjust range
limit is 270°, please do pay attention to this.
The factory intercalation:Light-control is max, Time setting is min.
Test
Connect the power and the load wire with
the sensor according to connection-wire
diagram;
~input
N
LBrown
Blue Red
output
Sensor
Load
Connection-wire diagram
Light-control
setting
Time setting



In front of the detection window there should be no hinder or unrest objects effecting detection.
Avoid installing it near air temperature alteration zones for example: air condition, central heating, etc.
Please don’t open the case for your safety if you find the hitch after installation.
Remark
1. Keep the sensor face to the area where human usually move.
2. Keep the sensor face to the position of the ambient light in order to get much more exact illuminance setting.
3. If detect the signal again within the time-delay, the time-delay will be over lied.


Notes
Electrician or experienced human can install it.
The unrest objects can’t be regarded the installation basis-face.



Some problem and solved way
The load don’t work:
a: Check the power and the load.
b: If the load is good.
c: Please check if the working light correspond to the ambient light.
The sensitivity is poor:
a:
Please check if in front of the detection window there is hinder that effect to
receive the signals.
b: Please check if the ambient temperature is too high.
c: Please check if the signals source is in the detection fields.
d: If the moving orientation is right.
The sensor can’t shut automatically the load:
a: If there is continual signal in the detection fields.
b: If the time delay is set to the longest.
c: If the power correspond to the instruction.
d: If the air temperature change near the sensor, for example air condition or central heating etc.
We are committed to promoting the product quality and reliability, however, all the electronic
components have certain probabilities to become ineffective, which will cause some
troubles.When designing, we have paid attention to redundant designs and adopted safety
quota to avoid any troubles.
This instruction, without our permission, should not be copied for any other purposes.
Warning!
● Please confirm with prefessional installation.
● Please cut off power supply before installation and removal operations.
● Make sure that you have cut off the power for safety purposes.
● Improper operation caused losses, the manufacturer does not undertake any responsibility.


Produktspezifikationen

Marke: Qazqa
Kategorie: Erleichterung
Modell: RLX-1201 Infrared Sensor Instruction

Brauchst du Hilfe?

Wenn Sie Hilfe mit Qazqa RLX-1201 Infrared Sensor Instruction benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Erleichterung Qazqa

Bedienungsanleitung Erleichterung

Neueste Bedienungsanleitung fĂŒr -Kategorien-