Powerplus POWXG9535 Bedienungsanleitung

Powerplus Pumpe POWXG9535

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Powerplus POWXG9535 (7 Seiten) in der Kategorie Pumpe. Dieser Bedienungsanleitung war für 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/7
POWXG9535 EN
Copyright © 2 VARO NV 202 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 SETTING TO WORK ........................................................................ 4
8.1 Venting the pump before use ................................................................................. 4
8.2 Setting the ON/OFF operating point 4 .......................................................................
9 CLEANING AND MAINTENANCE ................................................... 4
9.1 Maintenance guidelines .......................................................................................... 5
9.2 Cleaning the impeller .............................................................................................. 5
10 TECHNICAL DATA .......................................................................... 5
11 SERVICE DEPARTMENT ................................................................ 5
12 TROUBLESHOOTING ..................................................................... 6
13 STORAGE ........................................................................................ 6
14 WARRANTY ..................................................................................... 7
15 ENVIRONMENT ............................................................................... 7
16 DECLARATION OF CONFORMITY ................................................ 8
POWXG9535 EN
Copyright © 2 VARO NV 202 P a g e | 3www.varo.com
5 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions. Failure to follow all warnings and instructions
may result in electric shock, fire and/or serious injury. Save all warnings and instructions for
future reference. The term "power tool" in the warnings refers to your mains operated (corded)
power tool or battery operated (cordless) power tool.
6 BEFORE START-UP, NOTE THE FOLLOWING!
â–ª The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230 V ~ 50 Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of
protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal
trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be
operated while people are in the swimming pool or in the garden pond! Please contact your
electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please
have the following items checked by an expert:
â–ª Ground connection
â–ª Zero conductor
â–ª Fault current breaker switch must correspond the safety regulations of the power plants
and they must work faultlessly.
â–ª The electrical connections must be protected from moisture.
â–ª If there is danger of flooding, the electrical connections must be taken to higher ground.
â–ª Circulation of aggress e fluids, as well as the circulation of abrasive materials must be iv
avoided at all costs.
â–ª The submersible motor-driven pump must be protected from frost.
â–ª The pump must be protected from running dry.
â–ª Access on the part of children should also be prevented with appropriate measures.
Consistency
Your submersible pump is designed for the circulation of water with a maximum temperature
of 35° C. This pump may not be used for other fluids, especially motor fuels, cleaning fluids,
and other chemical products!
7 INSTALLATION
The submersible pump is installed as follows:
â–ª In a stationary position with fixed pipeline
or
â–ª in a stationary position with a flexible hose pipe.
Please note!
You should never install the pump by suspending it unsupported from its delivery pipe or
power cable. The submersible pump must be suspended from the specially provided handle or
be placed on the bottom of the shaft. To guarantee that the pump works properly, the bottom
of the shaft must be kept free of sludge and dirt of all kinds.
If the level of water sinks too far, any sludge in the shaft will dry out quickly and stop the pump
from starting up. ,Therefore it is necessary to check the submersible motor pump regularly (by
carrying out start-up tests). The floater is adjusted in a way that the pump can immediately be
started
Note!
The pump shaft should have minimum dimensions of 40 x 40 x 50 cm, so that the floating
switch can move freely.
POWXG9535 EN
Copyright © 2 VARO NV 202 P a g e | 4www.varo.com
Mains supply
Your new submersible pump is equipped with a shock-proof plug according to regulations. The
pump is designed to be connected to a 230V - 50 Hz earthed socket. Make sure that the
socket is sufficiently secured (min. 6 Amp.) and is in excellent condition. Introduce the plug
into the socket and the pump is ready to go.
Important Note!
If the mains cable or plug suffers any damage from external action, repairs to the cable should
be serviced by a qualified specialist using only standard spare parts. This will ensure that it
meets the required safety standards.
8 SETTING TO WORK
After having read these instructions carefully, you can set your pump to work, reconsidering
the following:
â–ª Check if the pump rests on the ground of the shaft.
â–ª Check of pressure cord has been attached properly.
â–ª Check if electrical connection is 230 V - 50 Hz.
â–ª Check if socket is in good condition.
â–ª Make sure that water and humidity can never come to the mains supply.
â–ª Avoid pump running dry.
8.1 Venting the pump before use
â–ª Always ensure that the pump is vented properly before commissioning the pump. Possibly
tilting back and forth several times until no more air bubbles appear, wait at least 15
seconds before the pump to start.
8.2 Setting the ON/OFF operating point
The ON and OFF operating point of the float switch can be set by adjusting the float switch in
its latching holder.
Before you put the pump into operation, please check the following:
â–ª The float switch must be installed so that the level of the ON operating point and the level
of the OFF operating point can be reached easily and with little force. To check this, place
the pump in a vessel filled with water, raise the float switch carefully by hand and then
lower it again. As you do so, note whether the pump switches on and off.
â–ª Make sure that the distance between the float switch head and the latching holder is not
too small. Proper operation is not guaranteed if the gap is too small.
â–ª When you set the float switch, make sure that it does not touch the base before the pump
switches off. Caution! Risk of dry-running.
This appliance cannot be used by children or people who are physically, mentally or
developmentally impaired, or people who lack experience or knowledge, except in case
these people receive instruction from a person responsible for their safety, a
supervisor, or by studying the preceding instructions concerning use of this appliance.
9 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.


Produktspezifikationen

Marke: Powerplus
Kategorie: Pumpe
Modell: POWXG9535

Brauchst du Hilfe?

Wenn Sie Hilfe mit Powerplus POWXG9535 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Pumpe Powerplus

Bedienungsanleitung Pumpe

Neueste Bedienungsanleitung für -Kategorien-