Powerplus POWXG9418 Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Powerplus POWXG9418 (4 Seiten) in der Kategorie Pumpe. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/4
POWXG9418 EN
Copyright © 2 VARO 016 NV Page | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 SETTING TO WORK ........................................................................ 4
8.1 Setting the ON/OFF operating point 4 .......................................................................
9 CLEANING AND MAINTENANCE ................................................... 4
9.1 Maintenance guidelines .......................................................................................... 4
9.2 Cleaning the impeller .............................................................................................. 5
10 TECHNICAL DATA .......................................................................... 5
11 SERVICE DEPARTMENT ................................................................ 5
12 TROUBLESHOOTING ..................................................................... 6
13 STORAGE ........................................................................................ 6
14 WARRANTY ..................................................................................... 6
15 ENVIRONMENT ............................................................................... 7
16 DECLARATION OF CONFORMITY ................................................ 7
POWXG9418 EN
Copyright © 2 VARO 016 NV Page | 2www.varo.com
SUBMERSIBLE PUMP
POWXG9418
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides
protection from flooding.
It is also used wherever water has to be moved from one place to another, e.g. in the home,
agriculture, horticulture, plumbing and many other applications.
It is not designed for commercial use.
WARNING! Read this manual and general safety instructions carefully
before using the appliance, for your own safety. Your power tool should
only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. Motor housing
2. Water inlet
3. Water outl et
4. Cable & plug
5. Floating switch
6. Carrying handle
3 PACKAGE CONTENT LIST
 Remove all packing materials
 Remove remaining packaging and transit supports (if existing)
 Check the completeness of the packing content
 Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
 Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with
plastic bags! Danger of suffocation!
Submersible pump with 10m electric cable (RNF) with earthed plug
Outlet connection.
manual
When parts are missing or damaged, please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Denotes risk of personal injury or
damage to the tool.
Read manual before use
In accordance with essential requirements of the European directive(s)
POWXG9418 EN
Copyright © 2 VARO 016 NV Page | 6www.varo.com
12 TROUBLESHOOTING
INCIDENTS
CAUSES
REMEDIES
Pump does not start
- No mains supply
- Floater does not switch
- Check mains supply
- Bring floater in a higher position
No flow
- Inlet sieve is clogged
- Pressure hose in bent
- Clean inlet sieve water jet
- Reset hose
Pump does not
switch off
- Floater cannot sink down
- Place pump properly on shaft gro und
Insufficient flow
- Inlet sieve is clogged
- Reduced pumping capacity
by dirty and abrasive water
- Clean inlet sieve
- Clean pump and replace worn-out
parts
Pump switches of
after short operating
period
- Thermal cutout stops
pumps due to dirty water
- Water too hot. Thermal-
cutout stops pump
- Remove mains plug. Clean pump
and shaft
- Make sure that a water temperature
of max. 35°C is not exceed
13 STORAGE
 Thoroughly clean the whole machine and its accessories.
 Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
 Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
 Don’t keep it in plastic bags to avoid humidity build- up.
14 WARRANTY
 This product is warranted for a 36-month period effective from the date of purchase by the
first user.
 This warranty covers all material or production flaws excluding : batteries, chargers,
defective parts subject to normal wear & tear such as bearings, brushes, cables, and
plugs, or accessories such as drills, drill bits, saw blades, etc. ; damage or defects
resulting from maltreatment, accidents or alterations; nor the cost of transportation.
 Damage and/or defects resulting from inappropriate use also do not fall under the
warranty provisions.
 We also disclaim all liability for any bodily injury resulting from inappropriate use of the
tool.
 Repairs may only be carried out by an authorized customer service center for Powerplus
tools.
 You can always obtain more information at the number 00 32 3 292 92 90.
 Any transportation costs shall always be borne by the customer, unless agreed otherwise
in writing.
 At the same time, no claim can be made on the warranty if the damage of the device is the
result of negligent maintenance or overload.
 Definitely excluded from the warranty is damage resulting from fluid permeation, excessive
dust penetration, intentional damage (on purpose or by gross carelessness), inappropriate
usage (use for purposes for which the device is not suitable), incompetent usage (e.g. not
following the instructions given in the manual), inexpert assembly, lightning strike,
erroneus net voltage. This list is not exhaustive.
 Acceptance of claims under warranty can never lead to the prolongation of the warranty
period nor commencement of a new warranty period in case of a device replacement.
 Devices or parts which are replaced under the warranty therefore remain the property of
Varo NV.
Produktspezifikationen
Marke: | Powerplus |
Kategorie: | Pumpe |
Modell: | POWXG9418 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Powerplus POWXG9418 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Pumpe Powerplus
29 April 2024
5 April 2024
29 März 2024
19 März 2024
11 März 2024
25 Januar 2024
31 Dezember 2023
15 September 2023
Bedienungsanleitung Pumpe
- Pumpe Crivit
- Pumpe SKS
- Pumpe Quigg
- Pumpe Makita
- Pumpe Parkside
- Pumpe Vonroc
- Pumpe Siemens
- Pumpe Powerfix
- Pumpe Trotec
- Pumpe Outwell
- Pumpe Einhell
- Pumpe Bartscher
- Pumpe Tacklife
- Pumpe Ultimate Speed
- Pumpe Eheim
- Pumpe Eurom
- Pumpe Hyundai
- Pumpe Fuxtec
- Pumpe Metabo
- Pumpe Kärcher
- Pumpe Güde
- Pumpe Biltema
- Pumpe Fieldmann
- Pumpe Enermax
- Pumpe Michelin
- Pumpe Florabest
- Pumpe Germania
- Pumpe Zipper
- Pumpe EUFAB
- Pumpe Jabsco
- Pumpe Sanibroyeur
- Pumpe Batavia
- Pumpe Topeak
- Pumpe Hayward
- Pumpe Milwaukee
- Pumpe Toolcraft
- Pumpe Osram
- Pumpe Bestway
- Pumpe AL-KO
- Pumpe Gardena
- Pumpe Verto
- Pumpe Cannondale
- Pumpe Lezyne
- Pumpe Neptun
- Pumpe Sicce
- Pumpe Danfoss
- Pumpe Hozelock
- Pumpe Ozito
- Pumpe Ferroli
- Pumpe Nibe
- Pumpe Sun Joe
- Pumpe Fluke
- Pumpe Generac
- Pumpe Lavorwash
- Pumpe Oase
- Pumpe OKAY
- Pumpe Plantiflor
- Pumpe Velda
- Pumpe Waldbeck
- Pumpe Zodiac
- Pumpe AstralPool
- Pumpe T.I.P.
- Pumpe Heissner
- Pumpe DAB
- Pumpe Baracuda
- Pumpe Rule
- Pumpe JANDY
- Pumpe Park Tool
- Pumpe Lifan
- Pumpe Elpumps
- Pumpe For_Q
- Pumpe Simpson
- Pumpe Pontec
- Pumpe BluGarda
- Pumpe Grundfos
- Pumpe Superior Pump
- Pumpe Zoeller
- Pumpe SHURflo
- Pumpe Ergotools Pattfield
- Pumpe Ebara
- Pumpe Basement Watchdog
- Pumpe Madimack
- Pumpe Barwig
- Pumpe Wayne
- Pumpe SANDPIPER
- Pumpe Zehnder Pumpen
Neueste Bedienungsanleitung für -Kategorien-
26 Juni 2024
26 Juni 2024
26 Juni 2024
26 Juni 2024
25 Juni 2024
14 Juni 2024
4 Juni 2024
4 Juni 2024