Ozito CPP-802 Bedienungsanleitung
Lesen Sie kostenlos die š deutsche Bedienungsanleitung fĆ¼r Ozito CPP-802 (8 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war fĆ¼r 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/8
7. Recommended Setup
Cleaning
Use a moist cloth to wipe down the pump housing. Allow to dry
thoroughly before storing in a dry location that is protected from bad
weather conditions.
Storage
If there is danger of frost, dismantle the device and accessories, clean
and store them in a place protected from frost.
Dismantle and store
1. Disconnect the device from the mains
supply.
2. Fully open any shut-off mechanisms
(spray nozzles, valves, etc.) in the
pressure line so that the air can escape
without obstruction.
3. Completely empty the pump by
unscrewing the water drain plug.
4. Dismantle the suction and pressure lines
from the device.
5. Store device in a frost-free room
(at least 5 Ā°C).
WARNING! MAKE SURE THE PUMP IS DISCONNECTED
FROM ELECTRIC POWER SUPPLY BEFORE
PERFORMING MAINTENANCE PROCEDURES.
WARNING! THE INPUT HOSE OR PIPE SHOULD BE
LOW ENOUGH IN THE WATER TO ENSURE THAT IF
THE WATER LEVEL FALLS, THE PUMP WILL NOT RUN DRY.
ENSURE THAT THIS IS CHECKED WHEN IN OPERATION.
WARNING! MAKE SURE THAT THE DEVICE AND
CONNECTED ACCESSORIES ARE DEPRESSURIZED
BEFORE CARRYING OUT ANY WORK ON THE DEVICE.
Positioning the hose or pipe
Position the input hose or pipe so that it rises from the water drawing
source to the pump. Where possible, avoid positioning the input hose
or pipe higher than the pump, as this would delay the escape of air
bubbles from the input hose or pipe and impede the priming process
(see section ā ā for description on priming the pump)Priming the pump
ā¢ī īTheīsuctionīlineīshouldībeīasīshortīasīpossible,īsinceītheīconveyingī
capacity decreases as the length of the line increases.
Note: A leaking hose or pipe will draw in air and therefore not draw in
any water.
Note: A non-return valve is recommended so that the water does not
run off when the pump is shut off.
Note:īAīsuctionīin-lineīīælterīwithīaī3000l/hourīminīīowīrate,īandī150ītoī
250īmicronīmeshīmustībeīusedītoīprotectītheīpumpīfromīsand,īdirtīetc.ī
TheīOzitoīPAPF-001īPre-īælterīorīequivalentīisīavailableīfromīBunningsī
stores.
Note: During the initial set-up, please purge all air from the system via
the discharge outlet highest in the system.
INSTALLATION
Recommended set-up
Connection with tank base below water pump
Connection with tank base level with water pump
Connection with tank base above water pump
F EIRM BAS
SOLID STRUCTURE
0
1
2
3
4
5
6Bar
WATERTANK
NON-RETURN
VALVE
DISCHARGE
OUTLET
GATE
VALVE
SUCTION LINE
150mm 150mm
UNION
COUPLING
depending on
installation
IN-LINE
FILTER
WATERTANK
GATE
VALVE
SUCTION LINE
150mm
F EIRM BAS
SOLID STRUCTURE
0
1
2
3
4
5
6Bar
DISCHARGE
OUTLET
150mm
UNION
COUPLING
depending on
installation
IN-LINE
FILTER
0
1
2
3
4
5
6Bar
150mm 150mm
WATERTANK
GATE
VALVE
SUCTION LINE
SOLID STRUCTURE
DISCHARGE
OUTLET
F EIRM BAS
UNION
COUPLING
depending on
installation
IN-LINE
FILTER
WARNING! TO ENSURE CORRECT PUMP OPERATION
IT IS ESSENTIAL THAT A SUCTION IN-LINE FILTER BE
USED FOR A CLEAN WATER SUPPLY.
MAINTENANCE
DESCRIPTION OF SYMBOLS CARING FOR THE ENVIRONMENT
Power tools that are no longer usable should not be disposed of
with household waste but in an environmentally friendly way. Please
recycle where facilities exist. Check with your local council authority
for recycling advice.
Recyclingīpackagingīreducesītheīneedīforīlandīællīandīrawīmaterials.ī
Reuse of recycled material decreases pollution in the environment.
Please recycle packaging where facilities exist. Check with your
local council authority for recycling advice.
Spare parts can be ordered from the Special Orders Desk
at your local Bunnings Warehouse.
For further information, or any parts not listed here, visit
www.ozito.com.au or contact Ozito Customer Service:
Australia 1800 069 486
New Zealand 0508 069 486
E-mail: enquires@ozito.com.au
SPARE PARTS
TROUBLESHOOTING
Problem LED Display Possible Cause Solution
Theīpumpīoperatesī
but water is not
īowing
Yellow, green and red
LEDs are on
Thereīisīairīinītheīpumpīhead Disconnectīfromīpowerīsupply,īopenītheīprimingīscrewīandīīællītheī
pump head with water
VerifyītheījointsīareīsealedītightlyīwithīTeīonītape
Theīsuctionīpipeīisīblocked Disconnect from power supply, clean the suction pipe
Theīpumpīisīnotīprimed FollowingīinstructionsīāPrimingīTheīPumpā
Theīin-lineīīælterīisīblocked Cleanītheīīælter
Theīinletīandīoutletīareīnotī
connected with the pipe or hose
correctly
Connect the inlet and outlet with pipe or hose correctly, ensure
thereīisīnoīleakage.īUseīTeīonītapeīonīallīconnections.
Noīwaterīīowīfromīsupply Checkīifītheīsupplyīsourceīhasīsufīæcientīwater
Theīpumpīwonātīstart No LEDs on Power not switched on If the yellow light doesnāt illuminate, check the mains supply
Yellow LED on Onībuttonīhasīnotībeenīpressed Onceīconnectedīwithītheīmainsīpower,ītheīyellowīlightīwillī
illuminate.īWhenīthisīoccurs,īpressītheīOnībutton.
Pumps stops No LEDs on Check the mains powerTheīmainsīpowerīisīdisconnected
Power failure When power is restored, the yellow light will illuminate, press the
Onībutton
Yellow and red LEDs
are on
Thereīisīairīinītheīpumpīhead Disconnectīfromīpowerīsupply,īopenītheīprimingīscrewīandīīællītheī
pump head with water
VerifyīallījointsīareīsealedītightlyīwithīTeīonītape
Theīsuctionīpipeīisīblocked Disconnect from power supply, clean the suction pipe
Theīpumpīisīnotīprimed FollowīinstructionsīāPrimingīTheīPumpā
Theīexternalīin-lineīīælterīisī
blocked
Cleanītheīexternalīīælter
Theīinletīandīoutletīareīnotī
connected with the pipe or hose
correctly
Connect the inlet and outlet with pipe or hose correctly, ensure
thereīisīnoīleakage.īUseīTeīonītapeīonīallīconnections
Noīwaterīīowīfromīsupply Check if the tank has plenty of water
YellowīLEDīīashing System has reached cut off
pressure of 3.8 bar
Thisīisīnormalīoperation.īTheīpumpīwillīstartīautomaticallyīonceī
theīoutletīsystemīpressureīisībelowī1.5ībar.īOpenīoutlet.
Pump cannot be
started by pressing
Onībutton
Yellow LED on and
redīLEDīīashing
Pump has gone to self protection
modeīdueītoīfrequentīon/offīcycle
Check if there are any leaks in the outlet system. Fix any leaks
found.īEnsureīTeīonītapeīisīusedīonīallīconnections.īPumpīmustī
be disconnected from mains power to reset.
WARNING! This product is intended for pumping water in a Home Domestic
application. Do not use it for corrosive, abrasive, explosive or dangerous liquids.
Fluids other than water will damage the water pump and/or create a īære hazard. Failure to
follow all instructions listed below may result in electric shock, īære and/or serious injury.
WARNING! This product is not suitable for use with drinking (potable) water.
This appliance is not intended for use by person (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
ā¢īī Ensureītheīwaterīpumpīisīdisconnectedīfromīmainsīpowerīwhenīinstalling.
ā¢īī īDoīnotīinstallīorīoperateītheīwaterīpumpīinīanīexplosiveīenvironmentīorīnearīīammableī
material.
ā¢īī Doīnotīoperateītheīwaterīpumpīwithoutīliquid.
ā¢īī Doīnotīrunītheīwaterīpumpīdry.
WARNING! The water pump together with associated pipework operate under
pressure. Do not disconnect water pump or pipework until internal pressure
has been released. Failure to do this could result in personal injury and damage to
property.
ā¢īī īAvoidīinsertingīhandsīintoītheīinlets/outletsīofītheīwaterīpumpīwhileīitīisīconnectedītoī
power.
ā¢īī īBeforeīusingītheīwaterīpump,īalwaysīinspectīitīvisually.īDoīnotīuseītheīpumpīifīitīisī
crackedīand/orīdamaged.īIfītheīwaterīpumpīisīdamaged,īcontactīOzitoīcustomerīservice.
ā¢īī īTheīwaterīpumpīhasīaībuilt-inīthermalīprotectionīoverloadīswitch.īTheīwaterīpumpīstopsī
ifīanīoverloadīoccurs.īTheīmotorīrestartsīautomaticallyīafterīitīhasīcooledīdown.
ā¢īī Theīpumpīmustīnotībeīusedīwhenīpeopleīareīinītheīwater.
ā¢īī īNeverīworkīorīperformīmaintenanceīonītheīpumpīwithoutīīærstīmakingīsureīitīhasībeenī
disconnected from the mains power.
ā¢īī Pollutionīofītheīliquidīcouldīoccurīdueītoīleakageīofīlubricantsī
IMPORTANT:
ā¢īī Avoidīinsertingīhandsīintoītheīmouthīofītheīpumpīifīitīisīconnectedītoītheīmains.
ā¢īī īTheīelectricalīconnectionīmustīalwaysībeīmadeīinīaīdryīarea.īMakeīsureīthatīelectricalī
connections are protected from inundations.
ā¢īī Protectītheīplugīandītheīpowerīcableīfromīheat,īoilīorīsharpīedges.
ā¢īī Ifīdamaged,īTheīpowerīcableīmustībeīreplacedībyīaīqualiīæedīelectrician.
ā¢īī īWhenīoperatingīinīswimmingīpools,īgardenīpondsīandīsimilarīplaces,ītheīdeviceīmustībeī
providedīwithīaīresidualīcurrentīofīnotīmoreīthanī30īmAībyīmeansīofīaīresidual-current-
operated protective device.
PRESSURE PUMP SAFETY WARNINGS
WARNING! When using mains-powered tools, basic safety precautions,
including the following, should always be followed to reduce risk of īære,
electric shock, personal injury and material damage.
Read and understand the manual prior to operating this pump.
Save these instructions and other documents supplied with this pump for future reference.
Theīelectricīmotorīhasībeenīdesignedīforī230Vīandī240Vīonly.īAlwaysīcheckīthatītheīpowerī
supply corresponds to the voltage on the rating plate.
Note:īTheīsupplyīofī230Vīandī240VīonīOzitoīpumpsīareīinterchangeableīforīAustraliaīandī
NewīZealand.īThisīpumpīisīearthedīinīaccordanceīwithīAS/NZSī60335-2-41.
Note: Theīpowerīoutletīusedīforītheīwaterīpumpīmustībeīprotectedībyīaī30mAīresidualī
current device or earth leakage circuit breaker. If the power outlet is external, ensure that
it is weather proof. If the supply cord is damaged, it must be replaced by an electrician or
aīpowerītoolīrepairerītoīavoidīaīhazard.īTheīwaterīpumpīhasīaībuilt-inīthermalīprotectionī
overloadīswitch.īTheīwaterīpumpīstopsīifīanīoverloadīoccurs.īTheīmotorīrestartsī
automatically after it has cooled down.
Using an Extension Lead
Always use an approved extension lead suitable for the power input of this product.
Beforeīuse,īinspectītheīextensionīleadīforīsignsīofīdamage,īwearīandīageing.īReplaceītheī
extensionīleadīifīdamagedīorīdefective.īThenīusingīanīextensionīleadīonīaīreel,īalwaysī
unwind the lead completely. Use of an extension lead not suitable for the power input of this
productīorīwhichīisīdamagedīorīdefectiveīmayīresultīinīaīriskīofīīæreīandīelectricīshock.
WARNING! Read all safety warnings and all instructions. Failure to follow the
warningsīandīinstructionsīmayīresultīinīelectricīshock,īīæreīand/orīseriousīinjury.
Save all warnings and instructions for future reference. The term āpower toolā in
the warnings refers to your mains-operated (corded) power tool or battery-operated
(cordless) power tool.
1. Work area safety
a. Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b. Do not operate power tools in explosive atmospheres, such as in the presence of
īammable liquids, gases or dust. Power tools create sparks which may ignite the dust
or fumes.
c. Keep children and bystanders away while operating a power tool. Distractions can
cause you to lose control.
2. Electrical safety
a. Power tool plugs must match the outlet. Never modify the plug in any way.
Do not use any adapter plugs with earthed (grounded) power tools.īUnmodiīæedī
plugs and matching outlets will reduce risk of electric shock.
b. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators,
ranges and refrigerators. Thereīisīanīincreasedīriskīofīelectricīshockīifīyourībodyīisī
earthed or grounded.
c. Do not expose power tools to rain or wet conditions. Water entering a power tool will
increase the risk of electric shock.
d. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the
power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged
or entangled cords increase the risk of electric shock.
e. When operating a power tool outdoors, use an extension cord suitable for outdoor
use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
f. If operating a power tool in a damp location is unavoidable, use a residual current
device (RCD) protected supply. Use of an RCD reduces the risk of electric shock.
3. Personal safety
a. Stay alert, watch what you are doing and use common sense when operating a
power tool. Do not use a power tool while you are tired or under the inīuence of
drugs, alcohol or medication. A moment of inattention while operating power tools may
result in serious personal injury.
b. Use personal protective equipment. Always wear eye protection. Protective
equipmentīsuchīasīdustīmask,īnon-skidīsafetyīshoes,īhardīhat,īorīhearingīprotectionī
used for appropriate conditions will reduce personal injuries.
c. Prevent unintentional starting. Ensure the switch is in the off-position before
connecting to power source and/or battery pack, picking up or carrying the tool.
Carryingīpowerītoolsīwithīyourīīængerīonītheīswitchīorīenergisingīpowerītoolsīthatīhaveī
the switch on invites accidents.
d. Remove any adjusting key or wrench before turning the power tool on.
A wrench or a key left attached to a rotating part of the power tool may result
in personal injury.
e. Do not overreach. Keep proper footing and balance at all times.īThisīenablesībetterī
control of the power tool in unexpected situations.
f. Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing
and gloves away from moving parts. Loose clothes, jewellery or long hair can be
caught in moving parts.
g. If devices are provided for the connection of dust extraction and collection
facilities, ensure these are connected and properly used. Use of dust collection can
reduce dust-related hazards.
4. Power tool use and care
a. Do not force the power tool. Use the correct power tool for your application. Theī
correct power tool will do the job better and safer at the rate for which it was designed.
b. Do not use the power tool if the switch does not turn it on and off. Any power tool
that cannot be controlled with the switch is dangerous and must be repaired.
c. Disconnect the plug from the power source and/or the battery pack from the
power tool before making any adjustments, changing accessories, or storing
power tools. Such preventive safety measures reduce the risk of starting the power tool
accidentally.
d. Store idle power tools out of the reach of children and do not allow persons
unfamiliar with the power tool or these instructions to operate the power tool.
Power tools are dangerous in the hands of untrained users.
e. Maintain power tools. Check for misalignment or binding of moving parts,
breakage of parts and any other condition that may affect the power toolās
operation. If damaged, have the power tool repaired before use.īManyīaccidentsīareī
caused by poorly maintained power tools.
f. Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp
cutting edges are less likely to bind and are easier to control.
g. Use the power tool, accessories and tool bits etc. in accordance with these
instructions, taking into account the working conditions and the work to be
performed. Use of the power tool for operations different from those intended could
result in a hazardous situation.
5. Service
a. Have your power tool serviced by a qualiīæed repair person using only identical
replacement parts. Thisīwillīensureīthatītheīsafetyīofītheīpowerītoolī
is maintained.
b. If the supply cord is damaged, it must be replaced by the manufacturer,
itsīserviceīagentīorīsimilarlyīqualiīæedīpersonsīinīorderītoīavoidīaīhazard.īī
GENERAL POWER TOOL SAFETY WARNINGS
ELECTRICAL SAFETY
Produktspezifikationen
Marke: | Ozito |
Kategorie: | pomp |
Modell: | CPP-802 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Ozito CPP-802 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp Ozito
16 Oktober 2024
16 September 2024
11 August 2024
8 August 2024
3 August 2024
2 August 2024
30 Juli 2024
28 Juli 2024
22 Juli 2024
9 Juli 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp KƤrcher
- pomp GĆ¼de
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp ZĆ©fal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024
1 Oktober 2024