Mercusys MS106LP Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Mercusys MS106LP (3 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 30 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
© 2023 MERCUSYS 7107500255 REV1.0.0
LED Explanation Switch Explanation
O: Ports run at100/10 Mbps and support PoE power supply up to 100m away.
On: Ports run at 10 Mbps and support PoE power supply up to 250m away.
Extend
MS106LP
Quick Installation Guide
For technical support, replacement services, user guides, and other
information, please visit https://www.mercusys com/support/..
Connection
PC
PoE Ports (1-4)
1. PoE ports can also connect to non-PoE devices, but only transmit data.
2. Non-PoE ports (ports 5-6) are recommended to connect to uplink devices like routers.
3. Ports 1-2 have higher priority than other ports in transmitting data if network
congestion occurs. It is recommended to connect key network devices (network
cameras, APs, etc.) to ports 1-2.
Notes:
Internet
IP Camera AP IP Phone
Powered Device (PD)
Power
On: The power is on
O: The power is o
Link/Act Status
On: Link present but no activity
Flashing: Transmitting or receiving data
O: No link
PoE Status
On: The port is providing PoE power
O: The port is not providing PoE power
O: The PoE Auto Recovery function is disabled.
On: The switch will constantly detect the working status of a PoE powered device (PD).
When the switch nds that the PD works abnormally, the switch will reboot it.
Recovery
O: Ports can transmit data with each other.
On: Ports 1-4 cannot transmit data with each other. They can transmit data only with the
uplink ports (ports 5-6).
Isolation
Ethernet Ports (1-6)
Power Adapter
Mercusys hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU,
2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at
https://www.mercusys.com/en/ce/
EU declaration of conformity
General Specications
Specications
IEEE 802.3i, IEEE 802.3u, IEEE 802.3x
CSMA/CD. 802.3af/at PD supported
6 10/100 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–4
10BASE-T:2-pair UTP/STP (≤100m) of Cat. 3 or above
100BASE-TX:2-pair UTP/STP (≤100m) of Cat. 5 or above
1000BASE-T:4-pair UTP/STP (≤100m) of Cat. 5e or above
1.2 Gbps
2K
Store-and-Forward
Automatically learning, automatically aging
External Power Adapter
Input: 100-240 VAC, 50/60 Hz
Output:
53.5 VDC/0.81 A
40 W (up to 30 W for each PoE port)
Standard
Network Media (Cable)
MAC Address Table
Interface
Switching Capacity
Protocol
Power Supply
Forwarding Method
MAC Address Learning
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service,
please contact us.
Place the device with its bottom surface downward.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Adapter shall be installed near the equipment and shall be easily accessible.
PoE Budget
Frequently Asked Questions (FAQ)
The Power LED should be lit when the power system is working normally. If the Power
LED is not lit, please check as follows:
A1:
Make sure the AC power cord/power adapter is connected the switch with power
source properly.
A2:
Make sure the voltage of the power supply meets the requirements of the input
voltage of the switch.
A3:
Make sure the power source is on.
Q1. Why is the Power LED not lit?
It is recommended that you check the following items:
A1:
Make sure that the cable connectors are rmly plugged into the switch and the
device.
A2:
Make sure the connected device is turned on and working well.
A3:
The cable must be less than 100 meters long (328 feet). If Extend Mode is enabled,
it should be less than 250 meters (820 feet).
Q2. Why is the Link/Act LED not lit when a device is
connected to the corresponding port?
When the total power consumption of connected PoE devices exceeds the maximum,
the PoE port with a smaller port number has a higher priority. The system will cut o
power to the ports with larger port numbers to ensure supplying to other ports.
For example, if port 1, 2 and 4 are consuming 10 W respectively, and an additional PoE
device with 15 W is inserted to port 3, the system will cut o the power of port 4 to
compensate for the overload.
Q3. Why are PoE ports not supplying power for PoE devices?
A1:
Before upgrading a connected PoE powered device (PD), disable PoE Auto
Recovery to avoid the PD’s damage.
A2:
When a PD does not send data packets to the switch for a long period in certain
scenarios (e.g. an IPC in sleep mode), disable PoE Auto Recovery to avoid the PD
repeatedly rebooting.
Q4. What should I notice before using the PoE Auto Recovery
feature?
Environmental and Physical Specications
CE, RoHS
0˚C to 40˚C (32˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90% non-condensing
5% to 90% non-condensing
Certication
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Mercusys hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of the Electromagnetic Compatibility
Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.
The original UK declaration of conformity may be found at
https://www.mercusys.com/support/ukca/
UK declaration of conformity
This is a class A product. In a domestic environment, this product may cause radio interference,
in which case the user may be required to take adequate measures.
CE Mark Warning
BSMI Notice
安全諮詢及注意事項
請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。
清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
注意防潮,請勿將水或其他液體潑灑到本產品上。
插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱請勿堵塞或覆蓋開口。
請勿將本產品置放於靠近熱源的地方。除非有正常的通風否則不可放在密閉位置中。
請不要私自拆開機殼或自行維修,如產品有故障請與原廠或代理商聯繫。
警告:為避免電磁干擾本產品不應安裝或使用於住宅環境。
限用物質含有情況標示聲明書
單元
nit
PCB
外殼
電源供應器
其他及其配件
限用物質及其化學符號
備考1.〝超出0.1 wt %〞〝超出0.01 wt %〞係指限用物質之百分比含量超出百分比含量基準值
Note 1:“Exceeding 0.1 wt % and “exceeding 0.01 wt % indicate that the percentage content of
the restricted substance exceeds the reference percentage value of presence condition.
備考2.〝○〞係指該項限用物質之百分比含量未超出百分比含量基準值。
Note 2:“○” indicates that the percentage content of the restricted substance does not exceed
the percentage of reference value of presence.
備考3.〝-〞係指該項限用物質為排除項目。
Note 3:The “-” indicates that the restricted substance corresponds to the exemption.
○ ○
Lead
(Pb)
-
-
Mercury
(Hg)
Cadmium
(Cd)
六價鉻
Hexavalent
chromium
(Cr+6
多溴聯苯
Polybrominated
biphenyls
(PBB)
多溴二苯醚
Polybrominated
diphenyl ethers
(PBDE)
○ ○
Explanation of the symbols on the product label
Note: The product label can be found at the bottom of the product (and its .I.T.E power supply).
Direct current
For indoor use only
RECYCLING
This product bears the selective sorting symbol for Waste electrical and
electronic equipment (WEEE). This means that this product must be
handled pursuant to European directive 2012/19/EU in order to be recycled
or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling
organization or to the retailer when he buys a new electrical or electronic
equipment.
Polarity of d.c. power connector
Energy eciency marking (level VI)
Class II equipment
Caution
Operator’s manual
Alternating current
Wall Mounting Specications
4#, (5#), 6#, 8#
Screw Standard of
ANSI B1.1
4#, (5#), 6#, 8#
MS105GP
Model
MS106LP
4#, (5#), 6#
4#, (5#), 6#
MS108GP
MS110P
7mm
Minimum Length
of Screw
7mm
7mm
7mm
1.5mm
Screw-Head-to-Wall
Minimum Distance
1.5mm
1.5mm
1.5mm
39mm
Wall-Mounting-Holes
Distance
39mm
105mm
105mm
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам
нормативних документів та вимогам, що передбачені чинними законодавчими актами України.
The POE output cannot be used to charge lithium batteries or devices with lithium batteries.


Produktspezifikationen

Marke: Mercusys
Kategorie: Nicht kategorisiert
Modell: MS106LP
Breite: 99.8 mm
Tiefe: 98 mm
Mitgelieferte Kabel: AC
Produktfarbe: Schwarz
Höhe: 25 mm
Energiequelle: AC/DC
AC Eingangsspannung: 220 V
AC Eingangsfrequenz: 50 Hz
Betriebstemperatur: 0 - 40 °C
Relative Luftfeuchtigkeit in Betrieb: 10 - 90 %
Netzstandard: IEEE 802.3af, IEEE 802.3at, IEEE 802.3x
Schnellstartübersicht: Ja
Stromverbrauch (Standardbetrieb): 1.87 W
Power over Ethernet (PoE): Ja
Stromverbrauch (max.): 44.8 W
Ethernet LAN Datentransferraten: 10, 100 Mbit/s
Temperaturbereich bei Lagerung: -40 - 70 °C
Luftfeuchtigkeit bei Lagerung: 5 - 95 %
Switch-Typ: Managed
Anzahl der basisschaltenden RJ-45 Ethernet Ports: 6
Basic Switching RJ-45 Ethernet Ports-Typ: Fast Ethernet (10/100)
Auto MDI/MDI-X: Ja
10G-Unterstützung: Nein
MAC-Adressentabelle: 2000 Eintragungen
Routing-/Switching-Kapazität: - Gbit/s
Rack-Einbau: Nein
Web-basiertes Management: Ja
Port-Spiegelung: Ja
Wandmontage: Ja
Stapelbar: Nein
Auto-Negotiation-Funktion: Ja
Unterstützung Datenflusssteuerung: Ja
Netzteil enthalten: Ja
Wärmeableitung: 152.32 BTU/h
Anzahl Power over Ethernet plus (PoE+) Anschlüsse: 2
Anzahl Power over Ethernet (PoE) Anschlüsse: 4
Power over Ethernet (PoE) Leistung pro Anschluss: 40 W
Traffic-Klassifizierung: Ja
Cloud-verwaltet: Ja

Brauchst du Hilfe?

Wenn Sie Hilfe mit Mercusys MS106LP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Mercusys

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-