Kidde Pi2010 Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Kidde Pi2010 (17 Seiten) in der Kategorie Rauchmelder. Dieser Bedienungsanleitung war fĂĽr 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/17
For your convenience, write down the following
information. If you call our Consumer Hotline,
these are the first questions you will be asked.
Smoke Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm).
National Fire Protection Association
(NFPA) and the manufacturer
recommends replacing this alarm
ten years from the date code:
Date of Purchase:
Where Purchased:
AC Wire-in Single and/or Multiple Station (up to 24 Devices)
Photoelectric/Ionization Smoke Alarm with 9 Volt Battery
Back Up and “HUSH” Control to temporarily silence nuisance
alarms.
Thank you for purchasing this smoke alarm. It is an important part of
your family’s home safety plan. You can trust this product to provide
the highest quality safety protection. We know you expect nothing less
when the lives of your family are at stake. Kidde alarms and accessories
CAN ONLY BE interconnected with other Kidde alarms and accessories
as well as specified brands and models of interconnect compatible
alarms. Connection of Kidde products to a non-specified manufactur-
er’s interconnect system, or connection with non-specified equipment
from another manufacturer into an existing Kidde system could result
in nuisance alarming, failure to alarm, or damage to one or all of the
devices in the interconnect system. Refer to the User Guide supplied
with each Kidde product for interconnect compatible models, brands,
and devices. Refer to the wiring instructions in section 3 for NFPA initi-
ating device limits.
Smoke Alarm User Guide
820-0905 REV. D 12/15
1475-7205-01
PI2010
For model: PI2010
The ion portion of this alarm detects products of combustion using
the ionization technique. It contains 0.9 microcurie of Americium
241, a radioactive material (see section 9).Distributed under U.S.
NRC License No. 32-23858-01E. Manufactured in compliance with
U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt
from any regulatory requirements. Do not try to repair the smoke
alarm yourself. Refer to the instructions in section 12 for service.
WARNING! BATTERY DOOR WILL NOT CLOSE UNLESS A
BATTERY IS PRESENT. REMOVAL OF THE SMOKE ALARM
BATTERY AND DISCONNECTING OR LOSS OF AC POWER
WILL RENDER THE SMOKE ALARM INOPERATIVE.
ELECTRICAL RATING: 120 VAC, 60HZ, 80mA maximum per alarm
(maximum 80mA for originating unit with 24 devices interconnected).
IMPORTANT! READ ALL INSTRUCTIONS BEFORE
INSTALLATION AND KEEP THIS USER GUIDE NEAR THE
ALARM FOR FUTURE REFERENCE.
CONTENTS OF THIS USER GUIDE
1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 -- LOCATIONS TO AVOID
3 -- INSTALLATION INSTRUCTIONS
4 -- OPERATION AND TESTING
5 -- NUISANCE ALARMS
6 -- MAINTENANCE
7 -- LIMITATIONS OF SMOKE ALARMS
8 -- GOOD SAFETY HABITS
9 -- NRC INFORMATION
10 -- NFPA PROTECTION STANDARD 72
11 --
CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION
12 -- SERVICE AND WARRANTY
1. RECOMMENDED LOCATIONS FOR ALARMS
• Locate the first alarm in the immediate area of the sleeping rooms.
Try to monitor the exit path as the sleeping rooms are usually far-
thest from the exit. If more than one sleeping area exists, locate
additional alarms in each sleeping area (See figure 3).
• Locate additional alarms to monitor any stairway as stairways act like
chimneys for smoke and heat.
• Locate at least one alarm on every floor level.
• Locate an alarm in every sleeping room.
• Locate an alarm in every room where
electrical appliances are
operated (i.e. portable heaters or humidi-
fiers).
• Locate an alarm in every room where
someone sleeps with the door closed.
The closed door may prevent an alarm
not located in that room from waking the
sleeper.
• Smoke, heat, and combustion products
rise to the ceiling and spread horizontally.
Mounting the smoke alarm on the ceiling
in the center of the room places it closest
to all points in the room. Ceiling mount-
ing is preferred in ordinary residential
construction.
• For mobile home installation, select loca-
tions carefully to avoid thermal barriers
that may form at the ceiling. For more
details, see MOBILE HOME INSTALLATION
below.
• When mounting an alarm on the ceiling,
locate it at a minimum of 4” (10 cm)
from the side wall (see figure 1).
• When mounting the alarm on the wall,
use an inside wall with the top edge of
the alarm at a minimum of 4” (10 cm)
and a maximum of 12” (30.5 cm) below
the ceiling (see figure 1).
• Put smoke alarms at both ends of a hall-
way or large room if the hallway or room
is more than 30 ft (9.1 m) long. For large
rooms, one smoke alarm is recommended
for every 500 square feet of floor space.
• In homes that are not well insulated,
extreme heat or cold can be transferred
from the outside to the inside through
poorly insulated walls and roof. This may
create a thermal barrier which can pre-
vent the smoke from reaching an alarm
mounted on the ceiling. If you are not
sure about the insulation in your home,
or if you notice that the outer walls and
ceiling are either hot or cold, install the alarm on an inside wall. In
such homes, install the smoke alarm with the top edge of the alarm
FIGURE 1
FIGURE 3
FIGURE 2
ANYWH ERE ALON G
TH IS BOLD SURFACE
12”
(300mm)
FIGURE 4


Produktspezifikationen

Marke: Kidde
Kategorie: Rauchmelder
Modell: Pi2010

Brauchst du Hilfe?

Wenn Sie Hilfe mit Kidde Pi2010 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Rauchmelder Kidde

Bedienungsanleitung Rauchmelder

Neueste Bedienungsanleitung fĂĽr -Kategorien-