Juwel Eccoflow 1000 Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Juwel Eccoflow 1000 (6 Seiten) in der Kategorie Aquarium. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/6
INSTRUCTION MANUAL
Eccoflow power head
www.juwel-aquarium.com
1
Introduction
Thank you for choosing a JUWEL Aquarium product.
Our products represent over 50 years experience in the manufacturing of aquariums and their acessories applying most modern
production techniques bringing together the JUWEL Aquarium system, which is both easy to use and simple to maintain.
Please read this instruction manual carefully and completely to make sure you have received all components before setting up
the aquarium. Please observe the safety instructions and maintenance guidelines given in this manual.
This instruction manual has been carefully prepared to provide you with accurate and complete information. All efforts have
been made to ensure that the information given is correct. However, we cannot accept responsibility for printing or other errors.
Technical details are always approximate and are not warranted characteristics and may be subject to change without notice.
This product fulfils the guidelines issued by the European Union (EU) and is therefore entitled to carry the CE mark.
2014/53/EU (Radio Rquipment Directive)
www.juwel-aquarium.de/en/declaration-of-conformity/
SAFETY INSTRUCTIONS:
Recommendation:
We recommend that you replace the parts subjected to wear and tear, e.g. the impeller, axle and the rubber axle holders, at
intervals of approx. 12 months in order to ensure the optimum function and operating quietness of the pump. Inquire at your
specialist retailer for assistance.
Recommendation:
If you wish to operate the pump JUWEL Eccoflow in a seawater aquarium, you will need the JUWEL Eccoflow ceramic shaft set
for the impeller. Item No. 85225 for pump JUWEL Eccoflow 500/600/1000. Item No. 85226 for pump Juwel Eccoflow 1500.
Inquire at your specialist retailer to that end.
SAFETY INSTRUCTIONS:
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
•
The power plugs of the electrical devices must not become moist. Connect
the power plugs to the power supply at such a height that the connection
cable forms a loop which would enable the water to drip down.
•
At all times, only operate the electrical devices for your aquarium (lighting,
heater, pump etc.) using an earth leakage circuit breaker (EL circuit breaker)
with a maximum tripping current of 30 mA. If the socket that you are using in
your home installation is not safeguarded with such a circuit breaker, please
use a commercially available power strip with an integrated earth leakage
circuit breaker.
•
The electrical devices may only be operated in rooms.•
Pull the power plug of all devices operated in water before coming into
contact with the water.
•
Never operate the power head out of water.•
Always unplug the power head from the power supply before removing it from the filter.•
The power head is intended for indoor use and for use in fluids up to 35°C.•
Never repair the electrical cord or plug. In case of damage replace the complete power head.•
2
The pump JUWEL Eccoflow
The new pump JUWEL Eccoflow distinguishes itself with operating quietness and a high flow rate. The new design and the
improved technology make the use and the maintenance even easier. Utilising the enclosed adapters, the pump JUWEL
Eccoflow is suitable as replacement for the pumps JUWEL Bioflow and also the JUWEL pump types 300/500/600/1000/1500.
The new pump JUWEL Eccoflow essentially consists of:
1. Motor
2. Impeller with axle and rubber mounts
3. Pump adapter for the JUWEL filter system Bioflow
4. Connection ring for the JUWEL Compact, Standard H and Jumbo filter system
(Pump adapter Order No. 85136)
Installation of the pump JUWEL Eccoflow in the filter system Bioflow
Super, M, L & XL
Please ensure that the impeller has been properly inserted and the pump adapter
has been firmly connected to the motor prior to the installation of the new pump.
Please proceed as follows:
1. Disconnect all electrical devices of the aquarium from the power grid.
2. Remove the outlet nozzles and remove the old pump from the filter.
3. Insert the new pump into the separation wall of the filter and firmly push it into
place.
4. Connect the outlet nozzle to direct the waterflow as desired from the outside to
the outlet opening of the pump. Reinstall the gasket into the round opening of the
filter housing when connecting the outlet. This decreases vibration transmissions.
Now the pump is ready for operation and you may reconnect the electrical devices
to the power grid.
3
Produktspezifikationen
Marke: | Juwel |
Kategorie: | Aquarium |
Modell: | Eccoflow 1000 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Juwel Eccoflow 1000 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Aquarium Juwel
8 September 2024
5 September 2024
22 August 2024
19 August 2024
18 August 2024
12 August 2024
7 August 2024
7 August 2024
6 August 2024
6 August 2024
Bedienungsanleitung Aquarium
- Aquarium Ferplast
- Aquarium Eheim
- Aquarium Ciano
- Aquarium Fishome
- Aquarium Fluval
- Aquarium SuperFish
- Aquarium Tetra
- Aquarium Oase
- Aquarium Reef One
- Aquarium Tetratec
- Aquarium Dennerle
- Aquarium Sera
- Aquarium Aquatlantis
- Aquarium Aqua One
Neueste Bedienungsanleitung für -Kategorien-
11 Oktober 2024
8 September 2024
5 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
31 August 2024
29 August 2024
29 August 2024