JANDY LXi Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JANDY LXi (56 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/56
H0286900 Rev T
ENGLISH
WARNING If these instructions are not followed exactly, a fire or explosion may
result, causing property damage, personal injury, or death.
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified
in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements
exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with
sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all warning notices and instructions that
accompany this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which
can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety,
Zodiac Pool Systems, Inc. strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of
this appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Jandy Pro Series
LXIâ„¢ Gas-Fired Pool and Spa Heater
INSTALLATION AND
OPERATION MANUAL
LP Gas for Indoor/Outdoor Use
Please refer to Section 4.3 of this manual for
precautions when installed indoors.
Page 3
ENGLISH
Jandy® Pro Series, LXI™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Table of Contents
Section 1. General Information 5 .......................
1.1 Introduction ......................................................... 5
1.2 Consumer Information and Safety 5 ......................
1.2.1 Spa/Hot Tub Safety Rules 5 ............................
1.2.2 Swimming Pool Energy Saving Tips............. 6
1.3 Warranty ............................................................. 6
1.4 Codes and Standards 6 .........................................
1.5 Technical Assistance .......................................... 6
1.6 Materials Installer Must Provide 7 .........................
1.6.1 Materials for All Applications......................... 7
1.6.2 Materials for Special Applications................. 7
1.7 Specications ..................................................... 7
1.7.1 GeneralSpecications ................................. 7
1.7.2 Dimensions................................................... 8
Section 2. Installation Instructions 9 .................
2.1 Introduction ......................................................... 9
2.2 Field Assembly .................................................. 9
2.3 Location Requirements 9 ......................................
2.3.1 Introduction................................................... 9
2.3.2 Clearances ................................................. 10
2.3.3 Flooring ...................................................... 10
2.3.4 Outdoor Installation .....................................11
2.3.5 Indoor and Outdoor Shelter Installations 12 ....
Section 3. Venting 12 ..
3.1 Combustion Air Supply ..................................... 12
3.2 Exhaust Venting 13 ...............................................
3.3 Vent Pipe Sizing and General Installation 14 .......
3.3.1 Outdoor Installations 14 ..................................
3.3.2 Indoor and Outdoor Shelter Installations ....... ..
14
3.3.3 Inspection and Replacement of Existing Vent
System with New Components .................. 16
Section 4. Gas Connections 16 ..........................
4.1 Gas Supply and Piping 16 .....................................
4.2 Manifold Pressure 17 ............................................
4.3 Special Precautions for LP Gas........................ 18
Section 5. Water Connections 18 .......................
5.1 Water Piping 18 .....................................................
5.2 Check Valve Installation 19 ...................................
5.3 Automatic Flow Control Valve........................... 19
5.4 Reversible Water Connections 19 .........................
5.5 Connections at Heater 21 ......................................
5.6 Pressure Relief Valve and Temperature Relief
Valve 22 .................................................................
5.7 Auxiliary Components, Chlorinators, Ozone Gen-
erators, and Sanitizing Chemicals 25 ....................
Section 6. Electrical 25 ........................................
6.1 General Information 26 ..........................................
6.2 Main Power 26 ......................................................
6.2.1 Converting the Heater for a 120V Power
Source 26 ........................................................
6.3 Bonding ............................................................ 27
6.4 Optional Pump Connection (Maintain Temp Fea-
ture) 27 ..................................................................
6.5 Optional Remote Controls 27 ................................
6.5.1 Connection to a Remote Pool-Off-Spa Selector
(3-Wire Connection) 28 ...................................
6.5.2 Connection to an AquaLink® RS Control Sys-
tem or Remote TSTAT (2-Wire Connection) 28
6.5.3 Connection to a Secondary User Interface 30
Section 7. Operating Instructions 31 .................
7.1 Normal Operation 31 .............................................
7.2 Start-Up ............................................................ 31
7.3 Operating the Controller 32 ...................................
7.3.1 Off Mode 32 .....................................................
7.3.2 Pool Mode - (Normal Heat) 32 ........................
7.3.3 Pool Mode - (Optional Maintain Heat) 32 ........
7.3.4 Spa Mode - (Normal Heat) 33 .........................
7.3.5 Spa Mode - (Optional Maintain Heat) 33 .........
7.4 User Setup Options 33 ..........................................
7.4.1 Language Setup 33 .........................................
7.4.2 Temperature Scale Setup 33 ...........................
7.4.3 Spa Timer Setup......................................... 33
7.4.4 Display Light Setup 35 ....................................
7.5 Set Point Lockout 35 .............................................
7.6 Lighting and Shutdown Procedures 35 .................
7.6.1 Lighting the Heater 35 .....................................
7.6.2 Shutdown ................................................... 36
7.7 Adjusting the Water Pressure Switch 36 ...............
7.8 Temperature Rise 37 .............................................
7.9 Burner Throat Pressure Adjustment ................. 38
Section 8. Maintenance 38 ..................................
8.1 Water Chemistry 38 ...............................................
8.2 Seasonal Care 38 ..................................................
8.2.1 Spring and Fall Operation 38 ..........................
8.2.2 Winterizing .................................................. 38
8.2.3 Spring Start-up 39 ...........................................
8.3 Inspection and Service 39 .....................................
8.3.1 Owner Inspection 39 .......................................
8.3.2 Professional Inspection 40 ..............................
Section 9. Troubleshooting 41 ...........................
9.1 General Heater Troubleshooting ...................... 41
9.2 Service Codes 41 ..................................................
9.3 Ignition Control LED Service Codes 41 .................


Produktspezifikationen

Marke: JANDY
Kategorie: Heizung
Modell: LXi

Brauchst du Hilfe?

Wenn Sie Hilfe mit JANDY LXi benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung JANDY

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung für -Kategorien-