JANDY Legacy Bedienungsanleitung

JANDY Heizung Legacy

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JANDY Legacy (48 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 25 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/48
Jandy Pro Series
Legacyâ„¢ Pool and Spa Heater
INSTALLATION AND
OPERATION MANUAL
MODEL ZODIAC® LRZ ELECTRONIC
NATURAL GAS AND LP
NOTE: LP Gas for Outdoor Use Only
Instructions for Legacy Heaters
from Rev F to current
H0299500 REVL
ENGLISH
WARNING If these instructions are not followed exactly, a fire or explosion may
result, causing property damage, personal injury, or death.
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified
in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements
exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with
sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all warning notices and instructions that
accompany this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which
can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety,
Zodiac Pool Systems, Inc. strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of
this appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Section 1. General Information 4 .......................
1.1 Introduction ........................................................4
1.2 Consumer Information and Safety 4 .....................
1.2.1 Spa/Hot Tub Safety Rules 4 ...........................
1.2.2 Swimming Pool Energy Saving Tips 5 ...........
1.3 Warranty ............................................................5
1.4 Codes and Standards 5 ........................................
1.5 Technical Assistance ..........................................6
1.6 Materials Installer Must Provide 6 .........................
1.6.1 Materials for All Applications .......................6
1.6.2 Materials for Special Applications 6 ...............
1.7 Specifications .....................................................6
1.7.1 General Specifications 6 ................................
1.7.2 Dimensions .................................................7
Section 2. Installation Instructions 8 .................
2.1 Introduction ........................................................8
2.2 Field Assembly ..................................................8
2.3 Location Requirements 8 ......................................
2.3.1 Introduction .................................................8
2.3.2 Clearances ..................................................8
2.3.3 Flooring .......................................................9
2.3.4 Outdoor Installation 10 ...................................
2.3.5 Indoor and Outdoor Shelter
Installations 10 ...............................................
Section 3. Venting........................................... 11
3.1 Combustion Air Supply ....................................11
3.2 Vent Pipe Sizing and General Installation 12 .......
3.2.1 Outdoor Installations 12 .................................
3.2.2 Indoor and Outdoor Shelter Installations ..12
3.2.3 Inspection and Replacement of Existing
Vent System with New Components ........13
Section 4. Gas Connections 13 ..........................
4.1 Gas Supply and Piping 13 ....................................
4.2 Manifold Pressure 14 ............................................
4.3 Special Precautions for LP Gas 15 .......................
Section 5. Water Connections 15 .......................
5.1 Water Piping 15 ....................................................
5.2 Check Valve Installation .......................................
16
5.3 Automatic Flow Control Valve 16 ..........................
5.4 Reversible Water Connections 16 ........................
5.5 Connections at Heater 18 .....................................
5.6 Pressure Relief Valve and Temperature
Relief Valve 18 ......................................................
5.7 Auxiliary Components, Chlorinators, Ozone
Generators, and Sanitizing Chemicals 20 ............
Section 6. Electrical........................................ 20
6.1 General Information 20 .........................................
6.2 Main Power 20 ......................................................
6.3 Bonding ............................................................21
6.4 Optional Remote Controls 21 ...............................
6.4.1 Connection to a Remote Pool-Off-Spa
Selector (3-Wire Connection) 23 ....................
6.4.1.1 Install the Remote Pool-Off-Spa
Selector 23 ...............................................
6.4.1.2 Configure the Control Panel 23 ...............
6.4.2 Connection to an AquaLink® RS, PDA,
Remote TSTAT (2-Wire Connection) or
Fireman's Switch 23 .......................................
6.4.2.1 Install the Remote TSTAT 23 ...................
6.4.2.2 Configure the Control Panel 23 ...............
6.4.3 Connection to a Secondary User
Interface 24 ....................................................
Section 7. Operating Instructions 24 .................
7.1 Normal Operation 24 ............................................
7.2 Start-Up ...........................................................24
7.3 Operating the Controller 25 ..................................
7.3.1 Off Mode 26 ...................................................
7.3.2 Pool Mode - (Normal Heat) 26 .......................
7.3.3 Spa Mode - (Normal Heat) 26 ........................
7.4 User Setup Options 26 .........................................
7.4.1 Language Setup 26 ........................................
7.4.2 Temperature Scale Setup 26 .........................
7.4.3 Spa Timer Setup .......................................26
7.4.4 Display Light Setup 26 ...................................
7.5 Set Point Lockout 27 .............................................
7.6 Lighting and Shutdown Procedures 27 .................
7.6.1 Lighting the Heater 27 ....................................
7.6.2 Shutdown ..................................................27
7.7 Adjusting the Water Pressure Switch 29 ...............
7.8 Temperature Rise 29 ............................................
Section 8. Maintenance 30 ..................................
8.1 Water Chemistry 30 ..............................................
8.2 Seasonal Care 31 .................................................
8.2.1 Spring and Fall Operation 31 .........................
8.2.2 Winterizing ................................................31
8.2.3 Spring Start-up 32 ..........................................
8.3 Inspection and Service 32 ....................................
8.3.1 Owner Inspection 32 ......................................
8.3.2 Professional Inspection 33 .............................
Table of Contents
Page 2
ENGLISH Jandy® Legacy™ Model LRZE Pool/Spa Heater by Zodiac® | Installation and Operation Manual
Section 9. Troubleshooting 33 ...........................
9.1 General Heater Troubleshooting ......................33
9.2 Service Codes 33 .................................................
Section 10. Professional
Maintenance and Service 36 ..........
10.1 General Information 36 .........................................
10.2 Natural-Draft Combustion System 36 ...................
10.3 Heater Components and Their Operation 36 ........
10.4 Electrical Troubleshooting ................................37
10.4.1 Electrical Power Supply 37 ............................
10.4.2 Controller .................................................38
10.4.3 Control Circuit Troubleshooting .................38
10.4.3.1 Transformer .......................................38
10.4.3.2 Fuse 38 ...................................................
10.4.3.3 Water Pressure Switch 38 ......................
10.4.3.4 Roll-Out Switch (Fusible Link) 38 ...........
10.4.3.5 Temperature Limit Switches Circuit....38
10.4.3.6 Gas Valve Voltage..............................39
10.4.3.7 Igniter/Ignition Control Circuit 39 ............
Section 11. Replacement Parts 42 .....................
11.1 Ordering Information 42 ........................................
11.2 Parts List 43 ..........................................................
11.3 General Exploded View 44 ...................................
11.4 Detailed Exploded View 45 ...................................
Table of Contents (Continued)
Page 3
ENGLISH
Jandy® Legacy™ Model LRZE Pool/Spa Heater by Zodiac® | Installation and Operation Manual


Produktspezifikationen

Marke: JANDY
Kategorie: Heizung
Modell: Legacy

Brauchst du Hilfe?

Wenn Sie Hilfe mit JANDY Legacy benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung JANDY

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung für -Kategorien-