GE Monogram®
42" Built-In Refrigerators
Custom
Options Guide
and
Installation
Instructions
With Custom Panel Dimensions
and Trim Kit
Installation Instructions
Models:
ZIS42N
ZISW42D
ZISB42D
These Monogram built-in refrigerators are
designed to be customized with decorator
door and grille panels. Field installed
panels are required.
Factory installed trim will accommodate
1/4" thick custom panels or optional
Lexan® and Stainless Steel panel kits.
Optional trim kits allow an even broader
range of custom appearance options.
Read this booklet carefully to accomplish the
desired appearance and to insure a trouble free
installation.
This booklet contains information and
illustrations to demonstrate custom
possibilities. Custom door and grille panel
sizes vary to accommodate the kit being
used. Dimensions for each application are
included and can be faxed or sent to the
cabinet manufacturer so that the panels can
be constructed accurately.
WARNING
WARNING
• Il ne faut utiliser cet appareil que pour l’usage pour
lequel il a été construit.
• Il faut réparer ou remplacer immédiatement tout
cordon d’alimentation électrique effiloché ou
endommagé.
• Débrancher le réfrigérateur avant le nettoyage ou
toute intervention.
• Les réparations doivent être faites par un
technicien qualifié.
ATTENTION
Cet appareil doit ĂŞtre correctement mis Ă  la terre.
Consulter « Mise à terre du réfrigérateur », page 15.
• Use this appliance only for its intended purpose.
• Immediately repair or replace electric service
cords that have become frayed or damaged.
• Unplug the refrigerator before cleaning or making
repairs.
• Repairs should be made by a qualified service
technician.
ATTENTION
This appliance must be properly grounded. See “Grounding the Refrigerator,” page 15.
Before you begin - Read these instructions completely and carefully.
IMPORTANT - Save these instructions for local inspector’s use.
IMPORTANT - OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions with your Use and Care Book for future reference.
2
Contents
Design Information
Advance Planning for a Flush Installation ................................................................................................................................... 3
Cutout and Product Dimensions .................................................................................................................................................. 3
Installation Between Base & Wall Cabinets ............................................................................................................................. 4
Installation At End-of-Run ............................................................................................................................................................. 4
Frameless Cabinets ........................................................................................................................................................................ 4
Accessory Panel Kits ..................................................................................................................................................................... 4
Advance Planning, Exterior Appearance Options ...................................................................................................................... 5
Appearance Examples, Trim Kit Descriptions ........................................................................................................................... 5
Custom Panel Dimensions
ZIS42N ............................................................................................................................................................................................ 6-9
ZISW42D, ZISB42D .................................................................................................................................................................. 10-13
Side Panel or Filler Options ........................................................................................................................................................ 14
Installation Instructions ........................................................................................................................................................... 15-20
Trim Kits
ZKH1 Trim Kit Installation Instructions
Custom Handles with 1/4" Thick Panels ............................................................................................................................. 21-25
ZG2 Trim Kit Installation Instructions
Grille Panel Frame Adjustment .................................................................................................................................................. 26
ZKT42 Trim Kit Installation Instructions
3/4" Thick Custom Panels ....................................................................................................................................................... 27-32
ZKHT1 Trim kit Installation Instructions
Custom Handles with 3/4" Thick Panels .............................................................................................................................. 33-37
ZKHSS1 Trim Kit Installation Instructions
Tubular Stainless Steel Handles for 1/4" Panel Installation ............................................................................................ 38-41
ZKHTSS1 Trim Kit Installation Instructions
Tubular Stainless Steel Handles for 3/4" Panel Installation ............................................................................................ 42-45
ZWCD1 Trim Kit Installation Instructions
Custom Dispenser Collar ........................................................................................................................................................ 46-47
If you have a question concerning the installation of this
product, call the GE Answer Center
® Consumer
Information Service at 800.626.2000, 24 hours a day,
7 days a week.
If you received a damaged refrigerator, you should
immediately contact your dealer or builder.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the GE Appliance Warranty. See the
Use & Care Guide for warranty information.
For Monogram local service in your area,
1-800-444-1845.
For Monogram service in Canada, 1-888-880-3030.
For Monogram Parts and Accessories, call
1-800-626-2002.
3
DESIGN
INFORMATION
Design Information
42" Built-In Refrigerator
Flush or
Semi-Flush
Enclosure
Installations
Side Panels Requirements:
• Side panels are not required whenever the
refrigerator is installed into an enclosure or between
pantry and oven cabinets.
• Side panels are required whenever the sides of the
refrigerator are exposed.
• Side panel sizes vary depending on the type of
installation being made.
To accomplish an attractive installation, you must:
1. Determine the need for side panels.
2. Determine side panel thickness.
3. Order matching side panels from the cabinet
manufacturer. Be sure to provide the exact
dimensions.
True Flush Installation
In a flush installation,
the refrigerator doors
will align evenly with the
front face of adjacent cabinet
doors. The refrigerator blends
into the surrounding cabinetry.
Semi-Flush Installation
These refrigerators
can also be installed
semi-flush into an enclosure
using the minimum cutout
width. The case trim creates a
frame around the opening.
Monogram built-in refrigerators can be installed flush
with typical 24-3/4" deep cabinetry.
When installed semi-flush, the case trim will conceal
slight gaps around the enclosure. The refrigerator will
project forward approximately 3/4" beyond the front
face of surrounding cabinetry.
In any installation situation, a wide range of appear-
ance options can be accomplished through the use of
one or more trim kits. See trim kit descriptions and
appearance options on page 5.
Enclosure
Cutout and
Product
Dimensions
• To achieve a flush fit the finished cutout width must
be at least 42" wide.
• A semi-flush installation requires 41-1/2" min. finished
cutout width.
• The electrical and water locations must be located as
shown for either type of installation.
*42" Min. for a flush installation
41-1/2" Min. for a semi-flush installation
Note: Additional cutout width may be required when
side panels are used. Add side panel thickness to the
finished cutout to calculate rough-in width. See
installation examples on the following page.
0"
3/4"
Advance Planning
42"
83" Min
84-1/2" Max
24-3/4"
*Finished Width
7"
Wall View
Electrical
Area
84 1/2" max
83-1/4" min
Finished
Opening
74" From Floor
to
Bottom
of Electrical
5"
18 3/8"
5" 3 1/2"
5"
3 1/2"
Water Supply
24 3/4" Total
Depth


Produktspezifikationen

Marke: GE
Kategorie: Nicht kategorisiert
Modell: ZWSP42D

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE ZWSP42D benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert GE

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-