TOOLS YOU WILL NEED
Installation
Kitchen and Bath Main Faucet
Instructions
Filtration System GXULQ/GNULQ
SAFETY PRECAUTIONS
Check with your state and local public works
department for plumbing and sanitation codes.
You must follow these guidelines as you install
the Kitchen and Bath Main Faucet Filtration
System. Using a qualified installer is recommended.
Be sure the water supply conforms with the
Performance Data. If the water supply conditions are
unknown, contact your municipal water company.
WARNING
Do not use with water that is
microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
It is highly recommended that a water shut-off valve
be placed directly upstream of your Kitchen and Bath
Main Faucet Filtration System.
PARTS INCLUDED
Filter Cartridge
Filter Head/Bracket
6 Feet of 3/8” Tubing
3/8 x 1/2” Faucet Adapter
3/8 Compression Hex Nut
3/8 Ferrule
3/8 Tube Insert
Mounting Screws
1/2 Compression to 3/8” Adapter
7/16” Compression to 3/8” Adapter
Optional accessories are available (Visa, MasterCard or
Discover cards accepted) by visiting our Website at ge.com
or from Parts and Accessories, call 800.626.2002 (U.S.) or
800.663.6060 (Canada).
Adjustable Wrench
Utility Knife
Phillips-Head
Screwdriver
49-50225-4 06-10 GE Printed in China
PROPER INSTALLATION
This Kitchen and Bath Main Faucet Filtration System
must be properly installed and located in
accordance with the Installation Instructions before
it is used.
Check with your local public works department for
plumbing codes. You must follow their guides as
you install the Kitchen and Bath Main Faucet
Filtration System.
Use the Kitchen and Bath Main Faucet Filtration
System on a potable, safe-to-drink, home COLD
water supply only. The filter cartridge will not
purify water or make unsafe water safe to drink.
DO NOT use on HOT water (100°F max).
Protect the Kitchen and Bath Main Faucet
Filtration System and piping from freezing. Water
freezing in the system will damage it.
Your Kitchen and Bath Main Faucet Filtration
System will withstand up to 100 psi water
pressure. If your house water supply pressure is
higher than 100 psi during the day (it may reach
higher levels at night), install a pressure reducing
valve before the system is installed.
Do not install on HOT WATER. The temperature
of the water supply to the Kitchen and Bath Main
Faucet Filtration System must be between the
minimum of 3F and the maximum of 100°F.
See the Performance Data section.
Do not install the Kitchen and Bath Main Faucet
Filtration System using copper solder fittings.
The heat from the soldering process will damage
the unit.
WARNING Discard all unused parts
and packaging material after installation. Small parts
remaining after installation could be a choke hazard.
Do not install filter in an outside location or
anywhere it will be exposed to sunlight.
System is
Tested and Certified by NSF International
against NSF/ANSI
Standard 42 for the reduction of
Chlorine, Taste and Odor and Particulates Class I and
against CSA B483.1.
Drill with 1/8” Drill Bit
HOT COLD
IN
OUT
Optional installation
STEP-BY-STEP
I
NSTAL
LATION I
N
ST
RU
CTIONS
Installation Overview
NOTE: Be sure to allow a minimum space of 11/22
under the system for removing the filter cartridge.
If you have copper tubing with 3/8compression fittings,
you’ll need to follow Step 3 Option B (Optional Installation).
CARTRIDGE SPECIFICATIONS
Performance Data – Filtration System GXULQ Using Filter GXULQR
nThis System has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI 42.
nActual performance may vary with local water conditions.
nDo not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after
the system.
2
Installation Instructions
FILTER CARTRIDGE REPLACEMENT
Replacement Filter Canister/Estimated Replacement Costs
GXULQRReplacement filter canister $29–34
For replacement parts, call toll-free 800.626.2002 (U.S.),
800.663.6060 (Canada–English), 800.361.3869 (Canada–French)
TO REMOVE FILTER:
Turn filter 1/4 turn to the left. The top surface of
the filter will move away from the bottom of the
head. Pull the filter down to remove.
HOT COLD
IN
OUT
Filter
Cartridge
INSTALLING THE SYSTEM
SELECT A LOCATION
Select a location for the system that is:
Protected from freezing.
Not exposed to direct sunlight.
Select and mark a location under the sink that allows
access for a filter cartridge change. See Section 4.
The system can be mounted vertically or horizontally.
DO NOT MOUNT THE SYSTEM UPSIDE DOWN.
B
A
1
DISCONNECT COLD WATER SUPPLY
Remove items from under the sink. Place a
bucket and some towels under the sink to collect
any water that may run out when disconnecting
the water supply lines.
Turn off the cold water supply valve and remove
the existing water supply tubing and fittings.
NOTE:
For copper tubing, leave the 3/8compression
fitting on the faucet stem. Go to Step 3, Option B.
B
A
2
3/8” x 1/2” Push to
Connect Adapter Filter Head/
Bracket
Standard No. 42: Aesthetic Effects
USEPA Influent Influent Effluent % Reduction Reduction
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Requirement
Chlorine taste and odor 2.0 mg/L ± 10% 1.9 mg/L <0.05 mg/L 0.05 mg/L >97.4% 97.4% ≥50%
Particulate, Class I
particles 0.5 to <1um**
≥10000 particles/mL 10333333 #/mL 20,500 #/mL 41,000 #/mL 99.8% 99.6% ≥85%
*Tested using a flow rate of 2 gpm (7.6 l/min); pressure of 60 psig; Operating Specifications
pH of 7.5 ± 0.5; temp. of 6± 5°F (20° ± 3°C) Capacity: certified for up to 2000 gallons (7,571 l); up to six months
**Measurement in particles/mL. Particles used were 0.5–1 microns. Pressure requirement: 20–100 psi (1.4–6.9 bar)
Temperature: 34°–100°F (1.1°–38°C)
FILTER CARTRIDGE REPLACEMENT (cont.)
TO REPLACE FILTER:
Push filter into the filter head/bracket. Turn filter
1/4 turn to the right until it stops. The top surface
of the filter will be flush with the bottom of the filter
head/bracket when fully installed.
NOTE: When correctly installed, the label will face out.
Turn on the cold water faucet to flush the filter for
5 minutes to remove air.
Change the batteries in the timer.
NOTE: Remove the water in the line to minimize the water released
during filter cartridge replacement. Turn off the cold water supply
valve and turn on the faucet for 5 seconds.
C
B
A
Shut-Off Valve
Ferrule
Hex nut
Tubing
insert
INSTALL TUBING
Push the tubing firmly into the collet on the
faucet adapter fitting until the pencil mark
is pushed next to the collet. (If the tubing
is removed, recut the end, measure, mark
and reinsert.)
Tubing must be fully inserted to avoid leaks.
To remove tubing: Depress and hold the white
collet; pull the tubing out to remove.
Pull out slightly on the tubing to ensure a good seal.
Press the other end of the tubing into the outlet
side of the filter.
6
C
B
A
3
Installation Instructions
CUTTING THE TUBING
Determine the length of tubing necessary from
the filter head/bracket to the faucet and from the
water supply line to the filter head/bracket by
holding the tubing in place to ensure it is the
correct length.
NOTE: 6 feet of tubing is supplied. Cut the
tubing into two sections according to your
requirements.
Cut tubing.
NOTE: Do not kink tubing.
NOTE: Check the end of the tubing to make sure
there are no cuts, nicks, flat spots or sharp edges.
If any of these are present, cut the end of the
tube with a utility knife.
Measure 3/4” from the end of the tubing
provided and mark with a pencil.
B
A
C
5
INSTALL THE HEAD/BRACKET
Using the filter head/bracket as a guide, mark
hole locations so that there is 1” between the
center of each screw. Fasten the filter
head/bracket to the wall with the Phillips screws
provided with the unit.
NOTE: Predrill 1/8holes for easier installation.
Make sure to leave at least 2-1/2
from the bottom of the system
to allow for easy replacement
of the filter cartridge.
Install screws only halfway so
you can slip the bracket onto the wall during
installation.
NOTE: There are three installation configurations.
Select the appropriate screws for installation: For
Cabinet Side Wall Installations, use 1screws; For
Drywall into Stud Installations, use 1-1/4 screws;
For Drywall with No Stud Installations, use lag bolts.
CAUTION:Be sure screw point does not
protrude through the wall into adjacent cabinet.
Tighten screws to secure the bracket.
D
C
B
A
4
2-1/2
3/4”
INCORRECT CUT
CORRECT CUT
Engagement
3/4” (1/4” tubing)
White Collet
(DO NOT REMOVE)
Pencil mark line
Insert tubing
3/4”
INSTALL FAUCET ADAPTER
Install the 3/8” x 1/2” faucet adapter to the faucet
threads.
DO NOT OVERTIGHTEN.
Option A – Typical Installation
Option B – Optional Installation
If you have copper tubing with a compression
adapter, you will NOT use the 1/2 faucet adapter.
Use a section of tubing, slide the compression
hex nut and 3/8
ferrule (tapered end away from
the compression nut) onto the tubing, and put in
the tubing insert.
3
3/8”
Compression adapter
Copper tubing
Insert
Ferrule
Hex nut
Tubing
Adapter
Faucet Threads


Produktspezifikationen

Marke: GE
Kategorie: Nicht kategorisiert
Modell: GNULQ

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE GNULQ benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert GE

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-