Franke FFPS20000 Bedienungsanleitung

Franke Kran FFPS20000

Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Franke FFPS20000 (4 Seiten) in der Kategorie Kran. Dieser Bedienungsanleitung war fĂĽr 23 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
LIMITED LIFETIME WARRANTY
All faucets installed in a private residence will carry a limited lifetime
warranty on all mechanical parts to be free of manufacturing defects
in material and workmanship under normal usage. All chrome finishes
carry a limited lifetime warranty; all other finishes are warranted for
five (5) years form the original date of purchase.
Marine and Outdoor Installation
warranted for Marine and Outdoor installations.
This warranty applies only to the original owner, providing the product
has been installed in accordance with our installation instructions,
used as recommended and in a normal residential application. In the
event of a warranty claim, the owner will be required to provide proof
of purchase - save sales receipt. This warranty covers all components
which make the product operational. Franke, at its option, may repair
or replace the product or components necessary to restore the pro-
duct to good working condition. Franke reserves the right to inspect
the installation prior to the actual replacement of the product or com-
ponent part. This warranty does not cover misuse or abuse, acciden-
tal damages, scuffs or scratches, improper installation, abnormal
usage, negligence or damage caused by improper maintenance or
cleaning. Normal wear of parts is excluded from the warranty.
Damage caused by impurities or acts beyond our control are not
covered. Any product or part which has been repaired or altered in
any manner outside of Franke's factory, unless previously authorized
in writing by Franke, will void warranty. Any replacement excludes
transportation and any labor re-installation costs. This warranty
does not allow recovery of incidental or consequential damages such
as loss of use, delay, property damage or other consequential dama-
ge, and Franke accepts no liability for such damages.
The Franke warranty is limited to the above conditions and to th e
warranty period specified herein and is exclusive. Franke DISCLAIMS
all other warranties, Dexpressed or implied, including IMPLIE
WA TA Y SRRANTIES OF MERCHAN BILIT AND/OR FITNES
FOR PART uA ICULAR PURPOSE. This warranty gives yo
specific legal rights that may vary from state to state .
Further information
For any further information about our products, about the installation of
REV.0 0 /2012 6 PAINI CODE VESTA
STANDARD TROUBLESHOOTINGMAINTENANCE AND
1. Shut o the water supply to the faucet.
2. Turn on the faucet briey to relieve any pressure inside the faucet.
3. Move the faucet handle to the “ OFF” position.
4. R the plastic cover C from the handle Aemove .
5. Remove the screw B using an allen key.
6. Pull the lever A from the body . base
7. Unscrew .the cap E
8. Unscrew cartridge .the lock nut F
9. Li mic disk ca ridge m theft cera rt G fro body and place it with ne re w
cartridge Ensu the lugs on bot om of the ca tridge sit operly. re two t r pr
in th e t y.alloca ed holes at the base of the bod
10. Re-assemble faucet in reverse order.
11. Test for leakage.
GENERAL MAINTENANCE
Clean aerator periodically for any buildup .
Do not use harsh detergents, solvents, chemical agents, metallic sponges,
etc. that could harm the surface and damage the nish.
Clean only with a soft sponge and soapy water.
SPARE / REPLACEMENT LIST
F20001**
INSTALLATION MANUAL
Franke Kitchen Systems
800 Aviation Parkway
Smyrna, TN 37167, USA
Phone: 800-626-5771
Email: ks-customerservice.us@franke.com
FFPS20000 Chrome
FFPS20080 Satin Nickel
A+B+C+D Handle assembly
F20002**
F20003
F20004
F20005
F20006
H+I+J+K.
F20007**
Pull out spray assembly F20008**
F20009
them or about the guarantee, please custome contact our r service
department:
F20010
P.
Q.
R.
S.
T.
F20011
Base washer
Mounting hardware kit
Weight
Pull out hose
Check valve
Pull out supply hose
Supply hoses
Base plate + Base gasket
Plastic flange
F20012
VESTA
the original purchaser of its faucets effective January 1, 2003.
: Franke faucets are NOT
Franke Kitchen Systems,LLC extends the following warranty to
E. Cap
F. Lock nut
G . Cartridge
H.
Washer G1/2"
I
Check Valve 1.75 gpm
K. Aerator
F20013
F20014
F20015
F20016**
F20017
REPLACING THE CARTRIDGE
L.
M.
N.
O.
**Must specify finish
" "CH chrome
" "SN satin nickel
(i.e. F20001CH or F20001SN)
TECHNICAL DATA
NOTE:
CONTENTS IN BOX
INSTALLATION INSTRUCTIONS
1. Remove all contents from the package and check for completeness.
3. Turn o water supply.
Recommended Water Pressure
Max. Water Pressure
Recommended Hot Water Temp.
Hole Size For Faucet
Certies this faucet complies with ASME A112.18.1 / CSA B125.1
& NSF 61, NSF 372 and AB1953
Flow Rate 1. GPM at 45 PSI6
30-75 PSI
1 PSI00
100° F
1 3/8”
1 Pull out spray assembly
2 Rubber washer
3 Pull out hose
4 Faucet assembly
5 Rubber washer
6 Base plate
7 Base plate gasket
8 Plastic flange
9 Rubber washer
10 Fixing plate
1 1Fixing nut
1 Pull out supply hose 2
1 3
Weight
1 Scr4ews
1 Supply hoses5
2. .Connect the pull out spray (1) to the pull out hose assy (3) hand tight
Ensure the rubber washer (2) is in place.
4. Cut a mounting hole 1 3/8 diameter (35mm) in the desired position in
counter top or sink (if one isn’t available).
5. Place the rubber washer (5) over the base of the faucet.
If your application has 3 holes to cover, install the base plate (6) and
base plate gasket (7) over the holes and install the faucet.
If your application is a single hole, the base plate (6) and base plate
gasket (7) are optional.
ATTENTION: The base plate gasket should be sitting the between
countertop and base . faucet plate
DO NOT use y or other sealant at this putt location.
NOTES:
S id sur ce in l ionol fa stal at : The c tert u ng sur ce tooun op mo nti fa needs
be at and ee of debris othe wise the fau et not sit operl fr r c may pr y.
For tile installations, avoid installing faucet near or on top of grout lines.
This may cause a weak joint between the faucet and the counter and
could cause leaks.
6. nstall the mounting ha dwa the I r re to base of faucet body in
the following r plastic flange ( ), orde - 8 rubber washer ( ),9
fixing plate as shown (10) .
7. Tighten with the fixing nut ( ) on the base of faucet body.11
10. Conne supp ses water sup thect the flexible ly ho (1 ) 5to the ply in
house.
11. Remove the aerator using 7/8” (22 mm) wrench, turn on water,
ush the faucet for any debris and check for leaks.
Reinstall the aerator and re ever c ensu ything is fun tioning properly.
8. Connect the pull out hose (3) to the pull out supply hose (1 )2.
9. Place the weight (1 ) on the pull out hose (3) with the screws (1 ) 3 4
approximately 2” (50mm) above the bend in the bottom of the pull out
hose.
Contact us immediatly if you see inconsistencies.
Phone: (1- 800-626-5771)
website: w.frankeksd.comww
email: ks-customerservice.us@franke.com
ATTENTION: Be sure to hold pull out supply hose (12) steady
when connecting pull out hose (3), otherwise pull out supply hose
(12) can be loosened and possibly cause leaks.


Produktspezifikationen

Marke: Franke
Kategorie: Kran
Modell: FFPS20000

Brauchst du Hilfe?

Wenn Sie Hilfe mit Franke FFPS20000 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Kran Franke

Bedienungsanleitung Kran

Neueste Bedienungsanleitung fĂĽr -Kategorien-