Extech EA80 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung fĂŒr Extech EA80 (11 Seiten) in der Kategorie Messung. Dieser Bedienungsanleitung war fĂŒr 15 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/11
User Manual
Indoor Air Quality Meter/Datalogger
Model EA80
AdditionalUserManualTranslationsavailableatwww.extech.com
C
C
EA80-en-GB_V3.6 11/16
2
Introduction
Congratulations on your purchase of the Extech EA80 Indoor Air Quality Meter. This meter
measures Carbon Dioxide (CO2, ppm) levels, ambient Temperature and Relative Humidity
(%RH). 16,200 readings can be logged by the meter and later transferred to a PC. This
meter is shipped fully tested and calibrated and, with proper use, will provide years of
reliable service.
Description
1. Display
2. Gas exhaust
3. Gas inlet port (rear of meter)
4. PC Interface jack
5. AC adapter socket (9V, 300mA)
6. Power Button
7. Data Hold Button
8. Backlight Button
9. MX/MN Button
10. SET Button
11. ALARM button
12. MEM (memory) button
13. (Enter) ï‚ż button
14. READ button
15. TIME button
16. °C/°F button
17. DEW button
18. WET button
19. Temperature / Humidity sensor probe
Three Tier LCD Display
1
2
3
4
5
6
78
9
10
11
12
13
14
15 16
17
18
19
SET
EA80-en-GB_V3.6 11/16
3
Preparation for Use
Power Supply
The meter is powered by six (6) 1.5V ‘AAA’ alkaline batteries or by an AC adapter.
Installing the Batteries
Insert six (6) AAA batteries as indicated by the diagram located on the inside of the
battery compartment.
When the battery voltage drops below the operating voltage, the “ + ” indicator will
be displayed indicating that the batteries need to be changed.
AC Adapter
The AC adapter allows the meter to be powered from a common AC wall outlet. When
using the AC adapter, the batteries (if installed) will be bypassed. The AC adapter is
not a battery charger.
Gas Inlet
Always ensure that the meter’s gas inlet port (3), the vented opening located on the
rear of the meter, and gas exhaust port (2), which is located at the top of the meter,
are not blocked.
Operation
Note: Exhaled CO2 will affect the accuracy of the reading; do not hold meter
near the face.
Taking Measurements
The sensor for Temperature, Humidity, Dew Point, and Wet Bulb measurements is
located in the remote probe. Hold the probe in the air in the area to be tested. DO NOT
immerse in liquid. The sensor for CO2 measurements is located at the top of the meter.
Selecting temperature units of measure (C/F)
Press the °C/°F button momentarily to toggle the temperature units.
CO2 Measurement
1. Press button to turn on the meter,
2. The sensor requires a 30 second warm-up
before displaying the CO2 measurement.
3. The meter sensor requires approximately10
minutes to stabilize in still air before the
readings can be considered accurate. Moving
the meter may decrease this stabilization time.
4. The primary display indicates the CO2 reading.
The secondary display indicates temperature. The third display indicates %RH.


Produktspezifikationen

Marke: Extech
Kategorie: Messung
Modell: EA80

Brauchst du Hilfe?

Wenn Sie Hilfe mit Extech EA80 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Messung Extech

Bedienungsanleitung Messung

Neueste Bedienungsanleitung fĂŒr -Kategorien-