Seite 1/56
2202007000_31-M0391_00_01 115 × 165 mm
www.emos.eu
M0391 | MD-210
GB Digital Multimeter
CZ Digitální multimetr
SK Digitálny multimeter
PL Multimetr cyfrowy
HU Digitális multiméter
SI Digitalni multimeter
RS|HR|BA|ME Digitalni multimetar
DE Digitales Multimeter
UA Цифровий мультиметр
RO Multimetru digital
LT Skaitmeninis multimetras
LV Digitālais multimetrs
EE Digitaalne multimeeter
BG Цифров мултиметър
2
1
300
300
300
300
300
EVERY
1
2
35
4
GB | Digital Multimeter
Before you begin using multimeter MD-210, read
this instruction manual thoroughly. It contains
particularly important passages concerning occupa-
tional safety principles when using the device. Such
passages are highlighted. Reading the manual will
prevent potential injury by electric current or damage
to the device.
The multimeter was designed in accordance with the
IEC-61010 standard regarding electronic measuring
devices in the category (CAT III 300 V), for 2nd pol-
lution degree.
Category CAT III is designed for measuring circuits
powered by a xed output power supply, such as relays,
sockets, switchboards, power supplies, short branching
circuits and lighting systems in large buildings.
alternating current (AC)
direct current (DC)
direct and alternating current (AC/DC)
earthing
double insulation
low battery
diode
fuse
warning
risk of injury by electric current
product complies with applicable EU standards
This symbol means: warning, risk of danger. Read
the manual in all cases where this symbol is used!
This symbol indicates risk of injury by electric
current.
ATTENTION
Comply with the following instructions in particular:
• Make sure the device is not damaged before you
begin using the multimeter. If you nd obvious
signs of damage on the body of the device, do not
make any measurements! Check that the surface of
the multimeter does not have scratches and that
the side joints are not coming apart.
• Do not measure voltage higher than 300 V, or
current higher than 10 A!
• The COM terminal must always be connected to
reference ground.
• Also check the measuring tips. Insulation on the
measuring probes should have no visible signs of
damage. Damaged insulation may result in injury
by electric current. Therefore, do not use damaged
measuring probes.
• If you nd that the multimeter is making abnormal
measurements, stop using it. These may be caused
by a disrupted fuse. If you are unsure of the cause
of the defect, contact a service centre.
• -Do not use or store the multimeter in environ
ments with high temperature, dust or humidity.
It is also not recommended to use the device in
environments with potentially strong magnetic
elds or risk of explosion or re.
3
• Do not measure voltages and currents higher than
indicated on the front panel of the multimeter.
Risk of injury by electric current or damage to
the multimeter!
• Check that the multimeter is working properly
before use. Test on a circuit with known electrical
values.
• Before you connect the multimeter to a circuit you
intend to measure, turn o the power to the circuit.
• -If you need to replace a component of the mul
timeter (e.g. battery, fuse), always use spare parts
of the same type and specifications. Change
parts only when the multimeter is disconnected
and turned o.
• Do not alter or otherwise interfere with the internal
circuitry of the multimeter!
• Be extra careful when measuring voltages higher
than 30 V AC rms, 42 V peak or 60 V DC. Risk of
injury by electric current!
• When using measuring tips, make sure you are
holding them behind the nger barriers.
• -Disconnect the measuring tips from the tested cir
cuit before opening the casing of the multimeter.
• Do not perform measurements if the multimeter‘s
casing is removed or loose.
• Change the battery once the low battery warning
indicator appears on the screen. Otherwise,
subsequent measurements may be inaccurate.
Incorrect measurements may then result in injuries
by electric current!
ATTENTION
Use multimeter MD-210 only in the manner specied
below. Otherwise, the device could get damaged or
the user may suer injury. Comply with the following
instructions:
Before measuring resistance, diodes or current, discon-
nect the circuits from the power supply and discharge
the high-voltage capacitors.
Before measuring, make sure the circular switch for
measuring range is in the correct position. Under no
circumstances should you make any changes to the
measuring range (by moving the circular switch for
measuring programs) while measuring. Doing so could
damage the device.
If you intend to measure current, check the multimeter‘s
fuse and turn o the power supply to the circuit before
you connect the multimeter.
When you are measuring, rst connect the black con-
ductor (probe) and then the red conductor (probe).
When disconnecting the testing conductors, discon-
nect the red one rst.
Maintenance Instructions
Attention
Do not attempt to repair or modify the multimeter in
any way if you are not qualied for the task or do not
have access to the necessary calibration equipment.
To prevent injury by electric current, make sure that
water does not enter the inside of the multimeter!
• -Disconnect the measuring tips from the tested cir
cuit before opening the casing of the multimeter.
• Regularly clean the body of the multimeter with a
moist cloth and a mild detergent. Perform cleaning
only when the multimeter is disconnected and
turned o.
• Do not use solvents or abrasive agents for cleaning!
• If you are not using the multimeter for an extended
period of time, turn it o and remove the batteries.
• Do not store the multimeter in places with high
humidity and temperature or in places with a
strong magnetic eld!
Device Description
Multimeter MD-210 is a compact device with a 3.5
digit display. It is designed for measuring direct and
alternating voltage, direct and alternating current,
resistance, temperature, test diodes and perform audio
testing of conductivity and of circuits. The multimeter
provides protection against overload and informs the
user when the battery is low. It is ideal for use in e.g.
workshops, laboratories and households.
Front View of the Multimeter
1 – Screen – displays 3.5 digits i.e. a maximum value
of 1999
2 – Function and range switch – allows selecting
functions and the desired range as well as turning
the multimeter on or o. If you are not using the
multimeter, turn it o. The battery will then last
you longer.
3 – 10 A socket – used for connecting the plug of the red
(positive) tipped measuring conductor to measure
currents in 10 A DC current range.
4 – socket – used for connecting the plug of the red
(positive) tipped measuring conductor to measure
voltage, resistance or current to up to 200 mA.
5 – COM socket – used for connecting the plug of the
red (positive) tipped measuring conductor.
Specications
Screen: LCD, 1999 (3.5 digits) with automatic polarity
indication
Measuring method: dual-slope integration via an
A/D converter
Reading frequency: 2–3× per second
Operating temperature and humidity: 0°C to 40°C,
<75 %
Storage temperature and humidity: -10°C to 50°C,
relative humidity <85 %
Power supply: 1× 9 V (6F22) battery
Fuses: F 250 mA/300 V, ø 5×20 mm, F 10 A/300 V,
ø 5×20 mm
Low battery: indication via a battery symbol on the
screen
Indication of exceeded range: shows „OL“ on the LCD
Measuring category: CAT III (300 V)
Enclosure: IP20
Dimensions 28 × 138 × 70 mm
Weight: 141 g (battery included)
Produktspezifikationen
Marke: | EMOS |
Kategorie: | Multimeter |
Modell: | MD-210 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit EMOS MD-210 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter EMOS
6 September 2024
2 September 2024
17 August 2024
10 August 2024
8 August 2024
6 August 2024
1 August 2024
31 Juli 2024
30 Juli 2024
30 Juli 2024
Bedienungsanleitung Multimeter
- Multimeter Basetech
- Multimeter Gembird
- Multimeter Brennenstuhl
- Multimeter Clas Ohlson
- Multimeter Profile
- Multimeter REV
- Multimeter Voltcraft
- Multimeter Bosch
- Multimeter Laserliner
- Multimeter Velleman
- Multimeter Powerfix
- Multimeter Alecto
- Multimeter TFA
- Multimeter FERM
- Multimeter Topcraft
- Multimeter Schneider
- Multimeter Tacklife
- Multimeter Abus
- Multimeter Elro
- Multimeter Stanley
- Multimeter Perel
- Multimeter Wago
- Multimeter Workzone
- Multimeter Somogyi
- Multimeter Amprobe
- Multimeter Metrix
- Multimeter Maxwell
- Multimeter Silverline
- Multimeter Yato
- Multimeter Brandson
- Multimeter Keithley
- Multimeter Hager
- Multimeter Kyoritsu
- Multimeter GW Instek
- Multimeter Monacor
- Multimeter Brüder Mannesmann
- Multimeter Milwaukee
- Multimeter JUNG
- Multimeter Testo
- Multimeter Elma
- Multimeter IDEAL
- Multimeter Digitus
- Multimeter Kingcraft
- Multimeter Testboy
- Multimeter Projecta
- Multimeter Greenlee
- Multimeter Multimetrix
- Multimeter Extech
- Multimeter BENNING
- Multimeter Metrel
- Multimeter Högert
- Multimeter APPA
- Multimeter Fluke
- Multimeter FLIR
- Multimeter Aldi
- Multimeter Gossen Metrawatt
- Multimeter Hubinont
- Multimeter Joy-it
- Multimeter Kewtech
- Multimeter Mastech
- Multimeter Megger
- Multimeter Micronta
- Multimeter PCE Instruments
- Multimeter Plieger
- Multimeter Sanwa
- Multimeter Skandia
- Multimeter Sonel
- Multimeter Steren
- Multimeter Uni-T
- Multimeter Wiha
- Multimeter Vimar
- Multimeter Owon
- Multimeter PeakTech
- Multimeter Amiko
- Multimeter Rigol
- Multimeter HT Instruments
- Multimeter Beha-Amprobe
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter Etekcity
- Multimeter Rohde & Schwarz
- Multimeter Strex
- Multimeter MBS
- Multimeter Kurth Electronic
- Multimeter Weidmüller
- Multimeter CEM
- Multimeter Klein Tools
- Multimeter Dasqua
- Multimeter Horex
- Multimeter Enovalab
- Multimeter Qian
- Multimeter Digi-tool
- Multimeter MGL Avionics
- Multimeter Cosinus
- Multimeter Weltron
- Multimeter EEVBlog
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Bearware
- Multimeter Noyafa
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
13 Oktober 2024
9 Oktober 2024
5 Oktober 2024
5 Oktober 2024
3 Oktober 2024