EMOS M3216 Bedienungsanleitung
EMOS
Multimeter
M3216
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für EMOS M3216 (6 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/6
M3216
GB Digital Multimeter
CZ Digitální multimetr
SK Digitálny multimeter
PL Multimetr cyfrowy
HU Digitális multiméter
SI Digitalni multimeter
RS|HR|BA|ME Digitalni multimetar
DE Digitales Multimeter
UA Цифровий мультиметр
RO|MD Multimetru digital
LT Skaitmeninis multimetras
LV Digitālais multimetrs
EE Digitaalne multimeeter
BG Цифров мултиметър
FR|BE Multimètre digital
IT Multimetro digitale
NL Digitale multimeter
ES Multímetro digital
2202021000_31-M3216_00_01_WEB 90 × 180 mm
www.emos.eu
2
1
2
10 10 11 10
1
8 9
234567
7
8
9
10
11
123456
GB | Digital Multimeter
Safety Instructions and Warnings
Read the user manual before using the device.
Follow the safety instructions in the manual.
• Carefully read through this instruction manual before you begin using the M3216.
It contains particularly important passages concerning safety when using the
device. Such passages are highlighted. Reading the manual will prevent potential
injury by electric current or damage to the device.
• The multimeter was designed in accordance with standard EN 61010-1
regarding electronic measuring devices within category (CAT III 600 V), 2nd
degree of pollution.
• Devices within category CAT III are used to measure circuits powered by a xed
output power supply, such as relays, sockets, switchboards, power supplies,
short branching circuits and lighting systems in large buildings.
• Do not use the multimeter to measure in ranges that fall into category IV!
Warning
Use the M3216 multimeter only in the manner specied below. Other uses may
damage the device or cause injury.
Comply with the following instructions:
• Before measuring resistance, diodes or current, disconnect the circuits from
the power supply and discharge the high-voltage capacitors. Use the corre-
3
sponding function for the given measurement. Before changing the range (or
switching functions) disconnect the multimeter‘s conductors from the circuit
that is being measured.
• Make sure the multimeter is not damaged before you begin using it. If you nd
obvious signs of damage on the body of the device, do not make any measure-
ments! Check that the surface of the multimeter does not have scratches and
that the side joints are not coming apart.
• Also check the insulation on the measuring probes. Damaged insulation may
result in injury by electric current. Do not use damaged measuring probes!
• Do not measure voltages above 600 V! If you intend to measure current, check the
multimeter‘s fuse and turn o the power supply to the circuit before you connect
the multimeter. Before measuring, make sure the circular switch for setting
the measuring range is in the correct position. Under no circumstances should
you make any changes to the measuring range (by moving the circular switch
for setting measuring programs) while measuring! Doing so could damage the
device. When you are measuring, rst connect the black conductor (- probe) and
then the other conductor (+ probe). When disconnecting the testing conductors,
disconnect the + probe rst.
• If you nd that the multimeter is making abnormal measurements, stop using
it. The fuse may be damaged. If you are unsure of the cause of the defect,
contact a service centre.
• Do not measure voltages higher than indicated on the front panel of the multim-
eter. Risk of injury by electric current or damage to the multimeter!
• Check that the multimeter is working correctly before use. Test on a circuit
with known electrical values.
• Before you connect the multimeter to a circuit you intend to measure, turn o
the power to the circuit.
• Do not use or store the multimeter in environments with high temperature, dust
or humidity. It is also not recommended to use the device in environments with
potentially strong magnetic elds or risk of explosion or re.
• When replacing parts of the multimeter (e.g. the battery or fuse) use spare parts
of the same type and specications. Change parts only when the multimeter is
disconnected and turned o.
• Do not alter or otherwise tamper with the internal circuitry of the multimeter!
• Be extra careful when measuring voltages higher than 30 V AC rms, 42 V peak
or 60 V DC. Risk of injury by electric current!
• When using the measuring tips, make sure you are holding them behind the
nger barriers.
• Do not perform measurements if the multimeter‘s casing is removed or loose.
• Replace the batteries once the screen starts displaying the low battery icon.
Otherwise, subsequent measurements may be inaccurate. Incorrect measure-
ments may then result in injuries by electric current!
• Only use 1.5 V alkaline batteries; do not use rechargeable 1.2 V batteries.
• Do not attempt to repair or modify the multimeter in any way if you are not
qualied to do so or do not have access to the necessary calibration equipment.
Make sure that water does not get into the multimeter – you could prevent
injury by electric current!
• Disconnect the measuring tips from the tested circuit before opening the cover
of the multimeter.
• Regularly clean the body of the multimeter with a moist cloth and a mild deter-
gent. Perform cleaning only when the multimeter is disconnected and turned o.
• Do not use solvents or abrasive agents for cleaning!
• If you will not be using the multimeter for a longer period of time, turn it o
and remove the battery.
• Do not store the multimeter in places with high humidity and temperature or in
environments with strong magnetic elds!
• The manufacturer is not liable for damage caused by improper use of the device.
• This appliance is not intended for use by persons (including children) whose
physical, sensory or mental disability or lack of experience and expertise prevents
safe use, unless they are supervised or instructed in the use of the appliance by
a person responsible for their safety. Children must always be supervised and
must never play with the appliance.
You can request technical assistance from the supplier:
EMOS spol. s r. o., Lipnická 2844, 750 02, Přerov
Produktspezifikationen
Marke: | EMOS |
Kategorie: | Multimeter |
Modell: | M3216 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit EMOS M3216 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter EMOS
6 September 2024
2 September 2024
17 August 2024
10 August 2024
8 August 2024
6 August 2024
1 August 2024
31 Juli 2024
30 Juli 2024
30 Juli 2024
Bedienungsanleitung Multimeter
- Multimeter Basetech
- Multimeter Gembird
- Multimeter Brennenstuhl
- Multimeter Clas Ohlson
- Multimeter Profile
- Multimeter REV
- Multimeter Voltcraft
- Multimeter Bosch
- Multimeter Laserliner
- Multimeter Velleman
- Multimeter Powerfix
- Multimeter Alecto
- Multimeter TFA
- Multimeter FERM
- Multimeter Topcraft
- Multimeter Schneider
- Multimeter Tacklife
- Multimeter Abus
- Multimeter Elro
- Multimeter Stanley
- Multimeter Perel
- Multimeter Wago
- Multimeter Workzone
- Multimeter Somogyi
- Multimeter Amprobe
- Multimeter Metrix
- Multimeter Maxwell
- Multimeter Silverline
- Multimeter Yato
- Multimeter Brandson
- Multimeter Keithley
- Multimeter Hager
- Multimeter Kyoritsu
- Multimeter GW Instek
- Multimeter Monacor
- Multimeter Brüder Mannesmann
- Multimeter Milwaukee
- Multimeter JUNG
- Multimeter Testo
- Multimeter Elma
- Multimeter IDEAL
- Multimeter Digitus
- Multimeter Kingcraft
- Multimeter Testboy
- Multimeter Projecta
- Multimeter Greenlee
- Multimeter Multimetrix
- Multimeter Extech
- Multimeter BENNING
- Multimeter Metrel
- Multimeter Högert
- Multimeter APPA
- Multimeter Fluke
- Multimeter FLIR
- Multimeter Aldi
- Multimeter Gossen Metrawatt
- Multimeter Hubinont
- Multimeter Joy-it
- Multimeter Kewtech
- Multimeter Mastech
- Multimeter Megger
- Multimeter Micronta
- Multimeter PCE Instruments
- Multimeter Plieger
- Multimeter Sanwa
- Multimeter Skandia
- Multimeter Sonel
- Multimeter Steren
- Multimeter Uni-T
- Multimeter Wiha
- Multimeter Vimar
- Multimeter Owon
- Multimeter PeakTech
- Multimeter Amiko
- Multimeter Rigol
- Multimeter HT Instruments
- Multimeter Beha-Amprobe
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter Etekcity
- Multimeter Rohde & Schwarz
- Multimeter Strex
- Multimeter MBS
- Multimeter Kurth Electronic
- Multimeter Weidmüller
- Multimeter CEM
- Multimeter Klein Tools
- Multimeter Dasqua
- Multimeter Horex
- Multimeter Enovalab
- Multimeter Qian
- Multimeter Digi-tool
- Multimeter MGL Avionics
- Multimeter Cosinus
- Multimeter Weltron
- Multimeter EEVBlog
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Bearware
- Multimeter Noyafa
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
13 Oktober 2024
9 Oktober 2024
5 Oktober 2024
5 Oktober 2024
3 Oktober 2024