MULTIMETER EM420B
Read this owner’s manual thoroughly before use
WARRANTY
This instrument is warranted to be free from defects in material and workmanship
for a period of two year.
Any instrument found defective within two years from the delivery date and returned to
the factory with transportation charges prepaid, will be repaired, adjusted, or replaced
at no charge to the original purchaser. This warranty does not cover expandable items
such as batteries or fuse. If the defect has been cause by a misuse or abnormal operation
conditions, the repair will be billed at a nominal cost.
SAFETY INFORMATION
The multimeter has been designed according to IEC-61010 concerning electronic meas-
uring instruments with a measurement category (CAT II 600V) and Pollution degree2
ELECTRICAL SYMBOLS
AC (Alternating Current)
DC (Direct Current)
DC or AC(alternating current or directive current)
Important safety information. Refer to the manual
Dangerous voltage may be present.
Earth ground
Fuse
Conforms to European Union directives
Double insulated.
Low battery
Diode
The maximum values is being held
The display data is being held
Fahrenheit
Centigrade
Continuity test
Measurement with clamp (optional), widening the eld of applica-
tions of the meter
Autorange
– Danger of electrical injury
Warning, Danger. Please pay attention to the passages of this manual
where this symbol is used.
WARNING
To avoid possible electric shock or personal injury, follow these guidelines:
• Do not use the meter if it is damaged. Before you use the meter, inspect the case.
Pay particular attention to the insulation surrounding the connectors.
• Inspect the test leads for damaged insulation or exposed metal. Check the test
leads for continuity. Replace damaged test leads before you use the meter.
• Do not use the meter if it operates abnormally. Protection may be impaired. When
in doubt, have the meter serviced.
• Do not operate the meter around explosive gas, vapor, or dust.
• Do not apply more than the rated voltage, as marked on the meter, between
terminals or between any terminal and earth ground.
• Before use, verify the meter’s operation by measuring a known voltage.
• When measuring current, turn o circuit power before connecting the meter in
the circuit. Remember to place the meter in the circuit. Remember to place the
meter in series with the circuit.
• When servicing the meter, use only specied replacement parts.
• Use with caution when working above 30V ac rms, 42V peak, or 60V dc. Such
voltages pose a shock hazard.
• When using the probes, keep your ngers behind the nger guards on the probes.
• Connect the common test lead before you connect the live test lead. When you
disconnect test leads, disconnect the live test lead rst.
• Remove the test leads from the meter before you open the case.
• Do not operate the meter with the cover removed or loosened.
• To avoid false readings, which could lead to possible electric shock or personal
injury, replace the batteries as soon as the low battery indicator appears.
• Do not use the test leads to measure the voltage which is more than 600V or the
current which is more than 10A.
• Remaining endangerment: When an input terminal is connected to dangerous live
potentional it is to be noted than this potential at all other terminals can occur!
• CATII-Measurement Category II is for measurements performed on circuits directly
connected to low voltage installation. Do not use the meter for measurements
within Measurement Categories III and IV.
CAUTION
To avoid possible damage to the meter or to the equipment under test, follow
these guidelines:
• Disconnect circuit power and discharge all high voltage capacitors before testing
resistance, continuity, diodes, or capacitance.
• Use the proper terminals, function, and range for your measurements.
• Before measuring current, check the meter’s fuse and turn power OFF to the circuit
before connecting the meter to the circuit.
• Before rotating Function / Range switch to change functions, disconnect test leads
from the circuit under test.
• Before inserting transistor to the adapter , always be sure all the test leads have
been removed from the meter
• Remove test leads from the meter before opening the battery cover or the case.
MAINTENANCE
To continue protection against re, replace fuse only with the specied voltage and
currents rating: F 250 mA L 250V, fast action.
To clean the meter, use a damp cloth and mild detergent only, do not use abrasives
or solvents on it.
GENERAL DESCRIPTION
This digital multimetr is compact 3,5 digits digital multimeter for measuring DC and
AC voltage, DC and AC current, resistance, temperature, diode, transistor, continuity,
capacitance ( only EM420B)and battery(only EM420A). It has the functions of polarity
indication, data hold, maximum value hold, overrange indicator and automatic power-
o. It can be operated easily and is ideal instrument tool.
Instruction
1 DISPLAY – 3,5 digit LCD with a max reading of 1999
2 RANGE button – The meter defaults to the autorange mode when you measure
the voltage, current or resistance. When the meter is in the autorange mode, AUTO
i s displayed.
To enter and exit the manual range mode:
a) Press RANGE button – The meter enters the manual range mode and the symbol
AUTO turns o.
Each press of the RANGE button increments the range. Then the highest range is
reached, the meter wraps to lowest range
b) To exit the manual range mode, press and hold down the RANGE button for
2 seconds, the meter returns to the autorange mode and the symbol AUTO is
displayed again.
3 FUNC. button – When you measure the current, pressing this button will switch
the meter between DC function and AC function.
When you measure the temperature, pressing this button will switch the meter
between °F mode and °C mode
When you measure the diode or the continuity functions.
4 POWER switch – It can be used to turn on/o the meter.
5 FUNCTION/RANGE SWITCH – This switch can be used to select desired function
and range.
6 10A Jack – Plug-in connector for the red test lead for current (200 mA ~10 A)
measurement.
7 COM Jack – Plug-in connector for black(negative) test lead.
8 INPUT Jack – Plug-in connector for the red test lead for all measurement except
current(≥200mA) measurements.
9 Button – To turn on or o the backlight, press and hold this button for about
2 seconds. The backlight will turns o automatically about 15 seconds later after
you turn on it.
10 Button – After pressing the button, the present reading is held on the
display, meanwhile is displayed on the LCD as an indicator. To exit th Hold Mode,
press the button again and the indicator will disappear.
11 Button – The hold the maximum value, press this button and will appear
as an indicator, the meter will hold the maximum of all readings taken since the
button was pressed. To exit the maximum value hold mode, just press this button
again and will disappear.
In some ranges, the maximum value hold mode is not available.
GENERAL SPECIFICATION
Display: LCD, 1999 counts, updates 2–3 times/sec
Overrange Indications: OL shown on display
Battery: 3× 1,5V, AAA
Polarity Indication: „–„ displayed atomatically
Low Battery Indication: shown on display
GB
3
Overload protection: 250V DC/AC rms
Max. Input Voltage: 200mV
Frequency range: 40Hz – 400Hz
Response: Average, calibrated in rms of sine wave
Resistance
Range Resolution Accuracy
200Ω 0.1Ω ±(1,2%+5)
2kΩ 0.001kΩ
±(1%+5)20kΩ 0.01kΩ
200kΩ 0.1kΩ
2MΩ 0.001MΩ ±(1,2%+5)
20MΩ 0.01MΩ ±(1,5%+5)
Open circuit Voltage: about 0,25V
Overload Protection: 250V DC/AC rms
Temperature
Range Resolution Accuracy
-20 °C ~1000 °C 1 °C
-20 °C ~0 °C: ±(5%+4)
0 °C ~400 °C: ±(1%+3)
400 °C ~1000 °C: ±(2%+3)
0°F ~1800°F 1°F
0°F ~50°F: ±(5%+4)
50°F ~750°F: ±(1%+3)
750°F ~1800°F: ±(2%+3)
Overload Protection: 250V DC/AC rms
Battery (only EM420A)
Range Resolution Function
1.5V 0.01V The approx. Voltage of the
battery is shown on the LCD
3V 0.01V
9V 0.01V
Overload Protection: 1,5V and 3V ranges: F 250 mA L 250V fuse
9V range: 250V DC/AC rms
Test current: 1,5V range: about 50mA
3V range: about 30mA
9V range: about 12mA
Capacitance
Range Resolution Accuracy
20nF 0.01 nF ±(8%+10)
200nF 0.1 nF
±(5%+5)
2µF 0.001 µF
20µF 0.01µF
200µF 0.1µF
1000µF 1µF ±(8%+10)
Overload Protection: 200µF and 1000µF ranges: no overload protection
the other ranges: F 250mA L 250V fuse
Open Circuit Voltage: about 0,5V
Overload Protection: 250V DC/AC rms
Transistor hFE Test
Range hFE Test Current Test Voltage
PNP & NPN 0–1000 Ib ~ 2 µA Vce ~ 1V
Diode and Continuity
Symbol Introduction Remark
The approximate forward vol-
tage drop will be displayed
Open circuit Voltage:
about 1,5V
The built-in buzzer will sound
if the resistance is less than
about 30Ω
Open circuit Voltage:
about 0,5V
Overload Protection: 250V DC/AC rms
For Continuity Test: When the resistance is between 30Ω and 100Ω,
the buzzer may sound or may not sound. When the
resistance is more than 100Ω, the buzzer won´t sound.
OPERATION INTRODUCTION
Measuring Voltage
1. Connect the black test lead to the “COM“ jack and the red test lead to the “INPUT“
jack.
2. Set the range switch to or position. Select auto range or manual range with
the “RANGE“ button.
Operating Temperature: 0 °C to 40 °C, <75%RH
Storage Temperature: -10 °C to 50 °C, <85%RH
Dimensions: 158 × 75 × 35mm
Weight: about 200g (including battery)
Specications
Accuracy is specied for a period of 1 year after calibration and at 18 °C – 28 °C (64°F-
82°F) with relative humidity <75%. Accuracy specications take the form of:
+/- (%of Reading)+(Number of Lest Signicant Digits)
DC Voltage
Range Resolution Accuracy
200mV 0.1mV ±(0,8%+5)
2V 0.001V
±(0,8%+5)20V 0.01V
200V 0.1V
600V 1V ±(1%+5)
Input Impedance: 10MΩ
Overload protection: 600 V DC/AC rms (200 mV range: 250V DC/AC rms)
Max. Input Voltage: 600 V DC
AC Voltage
Range Resolution Accuracy
2V 0.001V
±(1%+5)20V 0.01V
200V 0.1V
600V 1V ±(1,2%+5)
Input Impedance: 10MΩ
Frequency range: 40Hz – 400Hz
Overload protection: 600 V DC/AC rms
Response: Average, calibrated in rms of sine wave
Max. Input Voltage: 600 V AC rms
DC Current
Range Resolution Accuracy
200µA 0.1µA
±(1,2%+5)
2000µA 1µA
20mA 0.01mA
200mA 0.1mA
2A 0.001A ±(2%+10)
10A 0.01A
Overload protection: µA and mA ranges: F 250 mA L 250V fuse
2A and 10A ranges: unfused
Max. Input Current: INPUT jack: 200mA; 10A jack: 10A
(for measurements> 5A: duration <15 seconds,
interval >15 minutes)
Voltage drop: 200µA, 20mA and 2A ranges: 20mV
2000µA, 200mA and 10A ranges: 200mV
Maximum voltage in open circuit must be ≤ 250 V
AC Current
Range Resolution Accuracy
200µA 0.1µA
±(1,5%+5)
2000µA 1µA
20mA 0.01mA
200mA 0.1mA
2A 0.001A ±(3%+10)
10A 0.01A
Overload protection: µA and mA ranges: F 250 mA L 250V fuse
2A and 10A ranges: unfused
Max. Input Current: INPUT jack: 200mA; 10A jack: 10A
(for measurements> 5A: duration <15 seconds,
interval >15 minutes)
Voltage drop: 200µA, 20mA and 2A ranges: 20mV
2000µA, 200mA and 10A ranges: 200mV
Frequency range: 40Hz – 400Hz
Response: Average, calibrated in rms of sine wave
Maximum voltage in open circuit must be ≤ 250V
DC current (with clamp, optional – EM420A, B)
Range Resolution Accuracy
meter 200A 0.1mV/0,1A ±(1,2%+5)
meter 1000A 1mV/1A ±(1,2%+5)


Produktspezifikationen

Marke: EMOS
Kategorie: Multimeter
Modell: EM420B
Breite: 75 mm
Tiefe: 35 mm
Produkttyp: Digitales Multimeter
Akku-/Batterietyp: AAA
Höhe: 158 mm
Energiequelle: Akku
Anzahl unterstützter Akkus/Batterien: 3
Akku-/Batteriespannung: 1.5 V
Akkus/Batterien enthalten: Ja
DC Spannungsrange: 0.2 - 600 V
AC Spannungsrange: 2 - 600 V
Unterstützte Positionierung: Hand-Multimeter

Brauchst du Hilfe?

Wenn Sie Hilfe mit EMOS EM420B benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Multimeter EMOS

Bedienungsanleitung Multimeter

Neueste Bedienungsanleitung für -Kategorien-