Elektrobock CS3-4 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Elektrobock CS3-4 (2 Seiten) in der Kategorie niet gecategoriseerd. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
CS3-4
Timing switch for
1 second to 20 hours
(connection without neutral lead)
Is switched on immediately after pushing
the button, but the timing itself starts
only after button disconnecting.
1
L
CS3-4
N
1 s – 20 s
1 hod – 20 hod
30 s –10 min.
10 min. –200 min.
Is switched on immediately after pushing the button, but the
timing itself starts only after button disconnecting.
Up to 20 push-buttons
with built-in glow lamps
can be used for
control.
15-200 W
15-100 VA
timing
MADE IN CZECH REPUBLIC
Send the product for guarantee and after-guaran-
tee service to manufacturer's address.
MADE IN CZECH REPUBLIC
ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel./fax: +420 541 230 216
Technická podpora (do 14h)
Mobil: +420 724 001 633
www.elbock.cz
v souladu s RoHS
PbPb
LEAD FREE
CERTIFICATE OF GUARANTEE
(guarantee period for the product amounts to 2 years)
product No.: date of sale:
stamp of shop:
examined by:
CS34_aj.qxd 14.8.2006 21:47 Page 1
CS3-4
CS3-4 serves for delayed switching off of
resistance and induction loads.
Is switched on immediately after pushing
the button, but the timing itself starts only
after button disconnecting.
Setting of time
is linear, possible in the range from 0.5 s
to 20 hours. The coarse setting is made by
miniature switch according to table and
fine setting by trimmer with using of a small
screwdriver.
Thanks to special circuit used, a long-term
stability of the time set is ensured, without
substantial dependence on time, ambient
temperature and supply voltage.
CS3-1 activates the ventilator after switching
the lighting off.
CS3-1B activates the ventilator at set time
after switching the lighting on and
deactivates it at defined time after
switching the lighting off.
CS3-2 timing switch for lighting.
CS3-4M multifunctional timing switch, 8 function
- connection without neutr al lead.
t
t
ts
tcs
tc
Qsc
Qs
Summary of produced types:
Specification:
Nominal operating voltage Un=230 V
Nominal frequency of network fn=50 Hz
Resistance load 15–200 W
Inductive load 15–100 VA
(of ventilator)
Limit of interference suppression R 02
Cross section of installation leads 0,5 mm
2
Ambient temperature -10°C to + 55°C
IP-20 and higher - according to the type of installation
internal fuse FU 2A/H 5*20mm
Setting the time and installation should be
performed system that is not live and by
a person with appropriate qualification
in electrical engineering.
! Pozn.: CS3-4 is not suitable for switching of electronic
sources of light. For loads < 15VA we recommend connect
parallelly to the ventilator resistance 27-33 kΩ/ 2 W.
ts = interval of switching on
tc = the time set on CS3-4
tcs = total time of switching on of load (ts+tc)
CS34_aj.qxd 14.8.2006 21:47 Page 2

Produktspezifikationen

Marke: Elektrobock
Kategorie: niet gecategoriseerd
Modell: CS3-4

Brauchst du Hilfe?

Wenn Sie Hilfe mit Elektrobock CS3-4 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung niet gecategoriseerd Elektrobock

Bedienungsanleitung niet gecategoriseerd

Neueste Bedienungsanleitung für -Kategorien-