Electro Harmonix Spruce Goose Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Electro Harmonix Spruce Goose (4 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
POWER SUPPY REQUIREMENTS:
Voltage: Current: Polarity: 9VDC 20mA Center-Negative Battery: 9V
This device may be powered with an Electro-Harmonix 9.6DC-200, MOP-D10, or S8 power supply. Use of the
wrong adapter or a plug with the wrong polarity may damage the device and void the warranty. Do not exceed
12VDC on the power plug. Power supplies rated for less than 50mA can cause the device to act unreliably.
Operating Instructions
Connect your guitar to the INPUT jack of the Spruce Goose and the AMP
jack to your amp’s input. Press the footswitch to ensure the LED is lit.
Your Spruce Goose is now ready to play.
A good starting point is to set the knobs to their 12 o'clock positions, and
then adjust the LIFT toggle switch for the right amount of break-up. Further
tweak the knobs to dial-in your perfect setting.
Welcome to the Electro-Harmonix Spruce Goose, a compact,
natural overdrive with a wide range of tonal and gain settings.
Sculpt your sound with separate TREBLE and BASS EQ knobs.
Dial-in just the right amount of dirt, from barely there to over-
the-top, using the GAIN knob and LIFT switch. The Spruce
Goose also features mechanical relay true bypass on a soft
footswitch and optional 9V battery power.
- 2 -
Controls and Connections
1. GAIN Knob Adjusts the amount of gain and distortion. As you turn this knob clock-
wise, your signal gets louder and more saturated.
2. TREBLE Knob Controls the high frequency EQ of your signal. The higher the setting,
the brighter the output signal.
3. BASS Knob Controls the low frequency EQ of your signal. The bass EQ is at at noon.
As you turn BASS clockwise from noon, the bass response increases. As you turn
counterclockwise from noon, the bass response is cut.
4. VOL Knob Sets the output level of the Spruce Goose.
5. LIFT Switch LIFT gooses the input signal before it hits the overdrive circuit. The
mid position provides 9dB of gain, which helps get more drive from low output
pickups. The high position provides 21dB of gain, adding even more saturation and
distortion. The low position does not provide any additional gain.
6. FOOTSWITCH and STATUS LED The soft footswitch engages or bypasses the effect.
The status LED lights when the effect is engaged. The LED is off in bypass. The
- 3 -
Spruce Goose employs True Bypass with a mechanical relay. The footswitch includes
a momentary action when you press and hold the switch for more than half a
second. The momentary footswitch action may also be disabled, see the section
Footswitch Latching and Momentary Action.
7. INPUT Jack Audio input jack. Impedance: 680kΩ.
8. AMP Jack Audio output Jack. Impedance: 550Ω.
9. 9VDC Power Jack An optional 9VDC, center-negative power supply can be connected
to the power jack to provide power without a battery. The Spruce Goose requires 20mA
at 9VDC on a center-negative plug. Do not exceed 12VDC at the power jack.
When using a 9V battery, plugging into the INPUT jack activates power. The input cable
should be removed when the unit is not in use to avoid running down the battery.
To change the 9-volt battery, you must remove the 4 screws on the bottom of the
Spruce Goose. Once the screws are removed, you can take off the bottom plate and
change the battery. Please do not touch the circuit board while the bottom plate is
off, or you risk damaging a component.
Footswitch Latching and Momentary Action
The soft footswitch works both like a standard latching footswitch and a momentary
footswitch. The latching action means each press and release of the footswitch will
toggle between bypass and effect modes. A momentary change between bypass and
effect occurs when you press and hold the footswitch. The Spruce Goose changes state
immediately upon pressing the footswitch. If you continue to hold the footswitch—
for more than half a second—it will return to the previous state when you release
the footswitch.
Momentary hold action can be disabled completely by performing the following
procedure:
1. Power down the Spruce Goose.
2. Press and hold the footswitch.
3. While holding down the footswitch, apply power to the Spruce Goose.
4. Continue to hold down the footswitch. After about 2 seconds, the LED blinks.
A slow blink means momentary footswitch holds are disabled. A fast blink
means momentary footswitch holds are enabled.
5. Release the footswitch.
The momentary footswitch hold setting is remembered through power-cycles so you
can set it and forget it.
Notes and Specications
Audio input impedance at INPUT jack: 680kΩ
Audio output impedance at AMP jack: 550Ω
Current draw: 20mA at 9VDC
Power Supply: 9VDC, Center-negative polarity
True bypass switching


Produktspezifikationen

Marke: Electro Harmonix
Kategorie: Nicht kategorisiert
Modell: Spruce Goose

Brauchst du Hilfe?

Wenn Sie Hilfe mit Electro Harmonix Spruce Goose benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Electro Harmonix

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-