Draper Paragon E Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Draper Paragon E (3 Seiten) in der Kategorie Projektionsfläche. Dieser Bedienungsanleitung war für 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
Caution
1 Read instructions through completely before proceeding.
2 Follow instructions carefully. Installation contrary to instructions invalidates
warranty.
3 Pick up screen case from ends only. Picking case up at other points will
damage case may damage fabricand .
4 To insure a safe installation, the of the unit MUST BE entire weight
supported by the end-plates.
5 Entire bottom of screen case should be unobstructed to permit access to
bottom panel for making electrical connections or servicing.
6 Screen should be installed level (using a carpenter’s level).
7 Operating switch(es) packed separately in screen carton. Do not discard
with packing material.
8 Screen operates on 220V AC, 50 Hz., 1ph. current.
NOTE: Screen has been thoroughly inspected and tested at factory and found to
be operating properly prior to shipment.
Mounting Screen
Regardless of mounting method used, the following points apply:
1 Screen should be lifted into position only by the end mounting brackets.
Keep case level by lifting end plates simultaneously to prevent surface
damage. Draper provides eyebolts to use in hoisting the screen. DO NOT
use eyebolts to mount screen. Using both mounting holes in the mounting
brackets makes for a much more stable installation. Never attempt to lift
screen along its length.
2 The entire weight MUST BE of the unit supported by the end plates to provide
a secure installation. Anchoring of the intermediate case support brackets is
typically only needed to reduce any visible case deflection when the unit is
mounted into a ceiling pocket or ceiling tile opening. For installations that are
not recessed, the amount of case deflection is usually not noticeable.
3 Screen should be positively and securely supported so that vibration or even
abusive pulling will not weaken installation.
4 Installer must insure that fasteners used are of adequate strength and suitable
for the mounting surface chosen. Installer must also insure that wall or
ceiling structure are of adequate strength. Supporting hardware (chains,
cables, rods, etc.) must be essentially vertical.
5 Entire bottom of case must be readily accessible after installation is complete.
6 Front, back and top of case must be straight—not forced to warp or bow. Use
threaded rod and support brackets to keep large cases from warping. DO NOT
use support brackets to support the weight of the screen.
7 Do not use case to support adjacent sections of ceiling.
8 If optional ceiling flange trim kits are attached, use hardware provided.
9 If case is painted, slots on bottom of case should be shielded to protect viewing
surface from paint splatters or overspray.
Do not seal unit in ceiling until electrical connections have been made and
screen has been operated successfully.
Electrical Connections
Screen operates on 220V AC, 50 Hz., 1ph. current.
Junction box is located just above the closure panel, at the motor end of screen
(left hand motor location only on Paragon). To properly remove closure panel, two
people should follow the steps on page two of these instructions. The junction
box access plate is held closed with pan head screws and may be opened with
a Phillips screwdriver. Removal of access plate exposes brown, black and blue
pigtail leads and green internal ground wire per attached wiring diagram.
Screen is shipped with internal wiring complete and control switch(es) fully boxed.
Wire connecting screen to switch(es) and switch(es) to power supply should be
furnished by installer. Connections should be made in accordance with attached
wiring diagram, and wiring should comply with national and local electrical codes.
All operating switches should be “off” before power is connected.
Please Note: Do not wire motors in parallel.
Operation
When screen is first operated, Cycle unit down and up several times be cautious!
to confirm satisfactory operation.
220V AC Single Station Control—3-position up-off-down switch permits
operation to be stopped at any point. Factory adjusted limit switches automatically
stop screen when fully down or fully up.
220V AC Multiple Station Control (Not CE approved) Switches are similar
in appearance to 220 V AC Single Station Control. Screen stops when switch is
released and may be restarted in either direction. Factory adjusted limit switches
stop screen automatically when fully down or fully up.
24V ControlThree-button up-stop-down switch(es) stop at any point desired,
operate in any sequence. Factory adjusted limit switches automatically stop screen
when fully down or fully up. Installer should incorporate an all-pole disconnect in
the fixed wiring.
Key Operated Switching (Not CE approved) Two kinds of key-operated
switches are optionally available with this unit. The key-operated power supply 1
switch controls power to the screen and switches. When it is “off”, the switches
will not operate screen. Key may be removed from the switch in either “on or “off
position. A three-position key switch permits the screen to be operated directly 2
by key. In this case, the screen’s operator must always have a key.
RS232/Ethernet—Serial communication and network communication optionally
available with wall switches, RF or IR remote.
Adjustments
Please Note: Screen limits are factory set for optimum performance of the
screen. A procedure is outlined below for minor tweaks, but any adjustment
of these limits may negatively affect the flatness of the screen surface and
could also void the warranty. Please check with Draper prior to resetting
screen limits.
CAUTION: Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before adjusting limit
switches.
Caution: Rough handling in transit may cancel/reset motor limit settings.
To prevent viewing surface damage, be prepared to stop descending screen
if surface begins to retract instead of stopping or if motor does not shut off
when screen has fully retracted into case.
ADJUSTING “FULLY UP” POSITION—Put a small screw driver in the groove of
the yellow button on the motor and press vertically until hearing a "click". Raise
the screen by pressing the "up" switch on unit. Press the "stop" switch when the
screen is at the desired position. Then press the yellow button on motor until you
hear a "click", then release.
ADJUSTING “FULLY DOWN” POSITION—Put a small screw driver in the groove
of the white button on the motor and press vertically until hearing a "click". Lower
the screen by pressing the "down" switch on unit. Press the "stop" switch when the
screen is at the desired position. Then press the white button on motor until you
hear a "click", then release.
AT NO TIME SHOULD SCREEN BE UNROLLED ENOUGH TO EXPOSE ANY
PART OF SCREEN ROLLER.
Installation/Operating Instructions
220V Paragon/Series E and V Electric Screen by Draper
Copyright © 2014 Draper Inc. Form ParagonEV-220V_Inst14 Printed in U.S.A.
12"
13
1
/
4
"
5"
8"
2"
1
3
/
8
"
*
* - Case support bra ets will be enly spaced along the caseck ev
2" 2"
2¼"
2¼"
Series V
Viewing
Surface 21/8"
Series E
Viewing
Surface
Var ies
3
7
/
8
"1
3
/
8
"
Please see back page for dimensional diagrams of case and optional wall
mounting bracket, wiring diagrams and instructions on removing and replac-
ing the bottom closure.
These Installation/Operating Instructions are available in the official language of
the country where you purchase the product. Please contact your distributor to
request a copy.
Vous pourriez demander les instructions d’installation et d’opération traduises
dans la langue officielle du pays ou vous achetez le produit. Veuillez demander à
votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen
Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen
Sie die jeweilige Verkaufs-Abteilung.
If you encounter any difficulties installing or servicing your Paragon screen, call your dealer or
Draper, Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-1689.
Suitable for use
in environmen-
tal air space
in accordance
with Section
300-22(c) of the
National Electri-
cal Code, and
Sections 2-128,
12-010(3) and
12-100 of the
Canadian Elec-
trical Code, Part
1, CSA C22.1.
Caution: Do not remove the roller assembly from the case unless neces-
sary for repairs. If the roller assembly is removed, be sure motor is fully
re-seated in the bracket, and re-secure it carefully with the motor retaining
spring and screw (see diagram below).
Please note: Maximum torque for
tightening screw is 5 lb-inches.
Instructions
continued
on Page 2
US Patent No.
6,873,461
These instructions are meant as a guide only. They do not imply any responsibility
on the part of the manufacturer for improper installation or faulty workmanship at
the jobsite.
Case Dimensions*
Paragon/Series E and V 220V by Draper Page 2 of 3
83 mm
83 mm
73 mm
25 mm
3
/
8
" (9.5 mm) dia.
1
/
2
" (12 mm) dia.
73 mm
73 mm
Optional Wall
Mounting
Bracket
*Please Note: Optional wall brackets add 4.5 cm per bracket to case
length. Wall mounting bracket hole location is 2.54 cm from end of case.
www
.draperinc.com (765) 987-799
9
* * - Case support bra ets will be enly spaced along the caseck ev
51
mm
51 mm
57
mm
57
mm
Series V
Viewing
Surface
54
mm
Series E
Viewing
Surface
Varies
305 mm
337
mm
127
mm
203
mm
51 mm
35 mm
No. of
Intermediate
Case Width Brackets
<244 cm 0
> 244 and < 457 cm 1
> 457 and < 610 cm 2
> 610 and < 878 cm 3
Brackets are equally spaced from each
other and each end. For example, if the
case length is 513 cm, then each of the
two brackets will be placed approxi-
mately 171 cm from each end (with 171
cm between them).
Bottom Closure Removal/Replacement
Step 2
Step 3
Step 4
Removal and replacement of the bottom closure panel requires two people
positioned about 5' from each end of the panel. Closure should be handled
as shown in Step 5 below to prevent bowing of the closure during handling.
Step 1
Screw and washer
Before removing bottom closure, you
must first remove screws at each end
of case (see drawing at right).
Caution: Be sure to replace
screws and washers at each end
of case when replacing closure!
Tab-Tension Adjustment Procedure
Draper’s Tab-Tensioning System is factory-set, and under normal
circumstances will not require field adjustment. If, however, you notice
wrinkles, waves or other indications that the tensioning cables need to
be adjusted, follow the procedure below.
1 Determine which side requires adjustment.
2 Secure dowel with one hand.
3 Using Phillips-head screwdriver, depress spring-loaded adjustment screw
and slowly turn CLOCKWISE TO INCREASE tension, or
COUNTER-CLOCKWISE TO RELEASE tension. The screw adjusts in
¼ turn increments. Adjust only . one increment (¼ turn) at a time
4 If problem is not corrected, leave screen in position for 24 hours to allow
surface material to stretch into position.
5 If problem still is not corrected, repeat steps 2 and 3.
Caution: Do not touch
or bend surface.
C
O
U
N
T
E
R
-
C
L
O
C
K
W
I
S
E
ADJUSTMENT
SCREW
TENSIONING
CABLE
DOWEL
T
O
R
E
L
E
A
S
E
T
E
N
S
I
O
N
T
U
R
N
C
L
O
C
K
W
I
S
E
ADJUSTMENT
SCREW
TENSIONING
CABLE
DOWEL
T
O
I
N
C
R
E
A
S
E
T
E
N
S
I
O
N
T
U
R
N
Step 5
Wiring Diagrams
Please Note: Do not wire motors in parallel.
Neutral
L1
220v,
50 Hz.
Dashed wiring
by installer
Control
switch
Single Station Control
CE Approved
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (D n)ow
Black-220v (Up)
Dashed wiring
by installer
Neutral
Hot
Multiple Station Control
Not CE Approved
Cap off with wire
nut & tape
Red
Red
Red
Blue
Blue
Blue
Black
Black
220v, 50 Hz.
Black
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Green/Yellow (Motor Ground)
Paragon/Series E and V 220V by Draper Page 3 of 3
.draperinc.com (765) 987-799
Low Voltage and Remote Control
Dashed wi ng electricianri by
Low ltage wi ng othersvo ri by
Receiver
Button 3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
W
all Switch
To
230 VAC
Line
White-Common to screen & 230V lAC Neutra
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Green/Yellow (Ground)
Blue (Common)
Black (Up)
Brown (Down)
Inter
nal Screen Wi ngri
Green/Yellow
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
*A maximum of six (6)
LVC-IV modules can be
linked together.
N
L1
GND
Location of y ke
operated 0n-off
switch if furnished.
FUSE - 3.15 AMP
250 VAC 5x20mm
IR Eye Input
Low Voltage
Trigger
3-28 VDC
RS232/485
Inputs/Outputs


Produktspezifikationen

Marke: Draper
Kategorie: Projektionsfläche
Modell: Paragon E

Brauchst du Hilfe?

Wenn Sie Hilfe mit Draper Paragon E benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Projektionsfläche Draper

Bedienungsanleitung Projektionsfläche

Neueste Bedienungsanleitung für -Kategorien-