CyberPower Smart App Online OL6KRTMB Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung fĂŒr CyberPower Smart App Online OL6KRTMB (51 Seiten) in der Kategorie Unterbrechungsfreies Stromversorgungssystem. Dieser Bedienungsanleitung war fĂŒr 27 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/51
SAVE THESE INSTRUCTIONS
Please read this manual and follow the instructions for installation and operation.
©20 Cyber Power Systems, Inc. All rights reserve. K01- 00020 Ā ĈĆć-01
INSTALLATION AND OPERATION MANUAL
SMART APP ONLINE
UPS SYSTEM
OL6KRTMB | OL8KRTMB | OL10KRTMB
OL6KRTHW | OL8KRTHW | OL10KRTHW
II
©2 e f th020 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are th property o eir respective owners.
SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during installation and maintenance of
the UPS and batteries.
The SmartApp Online 6-10kVA UPS models that are covered in this manual are intended for installation in
an environment within 32°F to 104°F (0°C to 40°C), free of conductive contaminants.
SPECIAL SYMBOLS
Warning: High voltage – Risk of Electric Shock
Caution - Important Instructions: must always be followed.
Do Not Discard: the UPS or UPS batteries in trash. The batteries
contain lead acid. For more information, contact your local recycling
or hazardous waste facility.
Information, advice, help
See applicable user manual
III
©2020 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners.
SAFETY INSTRUCTIONS CONT.
PERSONAL SAFETY
CAUTION
To reduce the risk of ïŹre, connect the UPS to a branch circuit with 40 amperes
(6,000 VA)/50 amperes (8,000 VA)/70 amperes (10,000 VA) maximum over-current
protection in accordance with the National Electric Code, ANSI/NFPA 70.
The AC electrical service where the UPS is connected should be close to the unit and
easily accessible.
Please use only UL-marked mains cable, (e.g. the mains cable of your equipment), to
connect the UPS to the AC outlet.
Please use only UL-marked power cables to connect any equipment to the UPS.
When installing the equipment, ensure that the sum of the leakage current of the UPS
and the connected equipment does not exceed 3.5mA.
Do not unplug the unit from AC power during operation, as this will disconnect the
protective ground insulation.
Do not use an improper size power cord as it may cause damage to your equipment
and cause ïŹre hazards.
Make sure everything is turned o and disconnected completely before conducting
any maintenance, repairs or shipment.
DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT
OR NEAR A STRONG HEAT SOURCE!
DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING!
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO UPS
OUTPUT SOCKETS!
SERVICING OF BATTERIES SHOULD BE PERFORMED OR SUPERVISED BY
PERSONNEL KNOWLEDGE OF BATTERIES AND THE REQUIRED PRECAUTIONS.
KEEP UNAUTHORIZED PERSONNEL AWAY FROM BATTERIES!
FOR PERMANENTLY CONNECTED EQUIPMENT, A READILY ACCESSIBLE DISCONNECT
DEVICE SHALL BE INCORPORATED IN THE BUILDING INSTALLATION WIRING.
RISK OF ELECTRIC SHOCK
A battery can present a risk of electric shock and high short circuit current. The
following precaution should be observed when working on batteries:
Remove watches, rings or other metal objects.
Use tools with insulated handles.
The UPS must be connected to a grounded AC power outlet with fuse or circuit
breaker protection. DO NOT plug the UPS into an outlet that is not grounded. If you
need to power-drain this equipment, turn o and unplug the unit.


Produktspezifikationen

Marke: CyberPower
Kategorie: Unterbrechungsfreies Stromversorgungssystem
Modell: Smart App Online OL6KRTMB
Display-Typ: LCD
Akustische Signale: Ja
USB Anschluss: Ja
Breite: 433 mm
Tiefe: 820 mm
Gewicht: 104280 g
Mitgelieferte Kabel: Phone (RJ-11), Serial, USB cable
Produktfarbe: Schwarz
Akkuladezeit: 4 h
Akku-/Batterietechnologie: Plombierte BleisÀure (VRLA)
Höhe: 264 mm
Energieschutzeigenschaften: Overload, Short circuit
Stecker: Hardwire
Betriebstemperatur: 0 - 40 °C
Relative Luftfeuchtigkeit in Betrieb: 0 - 90 %
Verpackungsbreite: 650 mm
Verpackungstiefe: 619 mm
Verpackungshöhe: 1120 mm
Paketgewicht: 131220 g
Anzahl Ethernet-LAN-AnschlĂŒsse (RJ-45): 1
GehÀusematerial: Stahl
LED-Anzeigen: Battery replacement, Fault, Power
Temperaturbereich bei Lagerung: -20 - 45 °C
Luftfeuchtigkeit bei Lagerung: 0 - 95 %
GerÀuschpegel: 65 dB
Anzahl unterstĂŒtzter Akkus/Batterien: 20
Akku-/Batteriespannung: 12 V
Ausgangsspannung Gesamtverzerrungsfaktor THD: 5 %
BatteriekapazitÀt: 7 Ah
Formfaktor: Rackmount
Batteriegewicht: 76000 g
Ausgangsleistung: 6000 W
NachhaltigkeitskonformitÀt: Ja
Nachhaltigkeitszertifikate: RoHS
Eingangsfrequenz: 40/70 Hz
Rackmontageset: Ja
Höhe bei Betrieb: 0 - 3000 m
Leistungsfaktor: 1
Anzahl der AC-AusgÀnge: 13 AC-AusgÀnge
USV-Topologie: Doppelwandler (Online)
Eingangs-Betriebsspannung (min): 120 V
Eingangs-Betriebsspannung (max): 280 V
AusgangskapazitÀt: 6 kVA
Ausgangs-Betriebsspannung (min): 120 V
Ausgangs-Betriebsspannung (max): 240 V
Modem (RJ-11) Port: 1
AC-Steckertypen: Hardwire, NEMA 6–20R, NEMA 6–30R
Wellenform: Sine
Output Frequenz: 50/60 Hz
EMI/RFI LautstÀrkefilter: Ja
Druckanstiegsschutz: Ja
Akustische Alarm-Modi: Fault, Low battery alarm
Rack-KapazitÀt: 6U
Hot-Swap-Batterie: Ja
Höhe bei Lagerung: 0 - 15000 m
Batteriepatrone Wechsel: RB1270X10
Eingangs-Leistungsfaktor: 0.99
Crest-Faktor: 3:1
Ausgangs-Leistungsfaktor: 1
Kaltstart: Ja
Batteriebreite: 433 mm
Batterietiefe: 660 mm
Batteriehöhe: 132 mm