CyberPower RB1290X6D Bedienungsanleitung
CyberPower
Batterie
RB1290X6D
Lesen Sie kostenlos die đ deutsche Bedienungsanleitung fĂŒr CyberPower RB1290X6D (3 Seiten) in der Kategorie Batterie. Dieser Bedienungsanleitung war fĂŒr 37 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/3
1
4 5
2 3
1
3 4
5
2
21
43
5
21
3
5
4
21
43
5
21 3
54 6
Replacement Battery Pack Table
Model Name Battery QTY UPS or EBM Model
For USA and Canada:
4241 12th Ave East, Suite 400
Shakopee, MN 55379
Toll-free: (877) 297-6937
For all other regions:
Please visit our website for
local contact information.
CyberPower Systems, Inc.
www.cyberpower.com
OL1000RTXL2U, OL1500RTXL2U, BP36V60ART2U (LEFT),
OL1000ERTXL2U, OL1500ERTXL2U, BPE36V60ART2US (LEFT)
BP36V60ART2U (RIGHT), BPE36V60ART2US (RIGHT)
OL1000XL, OL1000EXL, OL1500XL, OL1500EXL
OL2200RTXL2U, OL3000RTXL2U, OL3000RTXL2UHV,
OL2200ERTXL2U, OL3000ERTXL2U
BP72V60ART2U, BPE72V60ART2US
OL2200XL, OL3000XL, OL2200EXL, OL3000EXL
BP240VL3U02, BP240V50A, BP240V50ART3U, OL8000, OL10000,
BPE240V50A, BPE240V50ART3U, OL8000E, OL10000E,
BPE240V50AS, BPE240V50ART3US
BP240VL3U01, BP240V30A, BP240V30ART3U, OL6000,
BPE240V30A, BPE240V30ART3U, OL6000E, BPE240V30AS,
BPE240V30ART3US
BP72V60ART2U, BPE72V60ART2US
BP36V60ART2U, BPE36V60ART2US
BP240V50A, BP240V50ART3U, OL8000, OL10000, BPE240V50A,
BPE240V50ART3U, OL8000E, OL10000E, BPE240V50AS,
BPE240V50ART3US
BP240V30A, BP240V30ART3U, OL6000, BPE240V30A,
BPE240V30ART3U, OL6000E, BPE240V30AS, BPE240V30ART3US
OL5KRTHD, OL6KRTHD, OL5KERTHD, OL6KERTHD
BP144VL2U01, BPE144VL2U01
RB1290X3L,
RBP0074
RB1290X3R,
RBP0079
RB1290X3A,
RBP0075
RB1290X6A,
RBP0076
RB1290X6B,
RBP0077
RB1290X6C,
RBP0078
RB1290X10,
RBP0072
RB1270X10,
RBP0073
RBP0131
RBP0132
RBP0133
RBP0134
RBP0144,
RB1260X12
RBP0145,
RB1290X6D
3
3
3
6
6
6
10
10
12
6
20
20
12
6
Battery Replacement
Instructions
K01-0000459-03
All CyberPower Systems replacement battery cartridges listed
in this manual use Non-Spillable Sealed Lead Acid Batteries.
CyberPower Systems encourages environmentally sound
methods for disposal and recycling of its battery cartridges.
Please dispose of and/or recycle your batteries in accordance
to the local regulations of your state.
Smart App Online Tower 6-10KVA SeriesSmart App Online Tower 1-3KVA Series
Smart App Online EBM for RT 1-1.5KVA SeriesSmart App Online RT 1-3KVA Series
Smart App Online RT 6-10KVA SeriesSmart App Online EBM for RT 2-3KVA Series
MODEL: OL1000RTXL2U, OL1500RTXL2U, OL2200RTXL2U,
OL3000RTXL2U, OL3000RTXL2UHV, OL1000ERTXL2U,
OL1500ERTXL2U, OL2000ERTXL2U, OL3000ERTXL2U,
OL1000RT JP, OL1500RT JP, OL2200RT JP,
OL3000RT JP
MODEL: OL1000XL, OL1500XL, OL2200XL, OL3000XL,
OL1000EXL, OL1500EXL, OL2000EXL, OL3000EXL,
OL1000XL JP, OL1500XL JP, OL2200XL JP, OL3000XL JP
MODEL: BP36V60ART2U, BPE36V60ART2U, BPE36V60ART2US
MODEL: BP240VL3U01, BP240VL3U02, BP240V30ART3U,
BP240V50ART3U, BPE240V30ART3U,
BPE240V50ART3U,BPE240V30ART3US,
BPE240V50ART3US
MODEL: OL6000, OL8000, OL10000, OL6000E, OL8000E,
OL10000E
MODEL: BP72V60ART2U, BPE72V60ART2U, BPE72V60ART2US
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Pull the battery pack out together with the retention panel slowly
and then put the new battery pack back into the UPS.
4 . Reconnect the battery pack connectors to the UPS. Then tighten
the screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Pull the battery pack out together with the retention panel slowly
and then put the new battery pack back into the UPS.
4 . Reconnect the battery pack connectors to the UPS. Then tighten
the screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panels.
3 . Pull the battery packs out together with the retention panels
slowly and then put the new battery packs back into the EBM.
4 . Reconnect the battery pack connectors to the EBM enclosure.
Then tighten the screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panels.
Unscrew the battery connector retention hardware. Disconnect
the battery power cables and then remove the panel itself.
3 . Pull the battery packs out slowly and then put the new battery
packs back into the compartment.
4 . Reconnect the battery pack to the EBM enclosure and screw on
the battery connector retention hardware. Tighten the screws of
the battery retaining cover.
- It is very important to reconnect battery connections WARNING
with the correct polarity. Connectors are color coded red and
black for positive and negative polarity respectively. Permanent
damage may be caused to the equipment if polarity is reversed.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Raise the battery retention panel above the battery compartment
opening to allow the battery trays to be pulled out. Then put the
new battery trays into the compartment.
4 . Align and reconnect the battery connectors and tighten the
screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Raise the battery retention panel above the battery compartment
opening to allow the battery trays to be pulled out.
4 . Pull the battery trays out slowly and then put the new battery
trays back into the compartment.
5 . Reconnect the battery connectors and tighten the screws of
battery retention panel.
6 . Reinstall the front panel.
1
4 5
2
7
6
3
1 7 8
9
2 3
4
5 6
Smart App Online RT 5-6KHD Series
MODEL: OL5KRTHD, OL6KRTHD, OL5KERTHD, OL6KERTHD
5 . Pull the battery trays out slowly
and then put the new battery
trays into the compartment.
6 . Assemble the battery retention
bracket and tighten the thumbscrew.
7 . Connect the internal battery connector and battery management
module connector. Ensure that they are seated properly
(connector will click into place).
8 . Tighten the screw on the battery access door and install the
front panel.
9 . Execute a battery test via the LCD control panel. To do this go
to the Main Menu and select the Diagnostics Icon, then select
Battery Test and Activate. After the Battery Test, go back to the
Main Menu and select the Set UP icon, then select Battery Install
Date to set the battery installation date. This operation can also
be done via PowerPanelÂź Business Edition Agent or the RMCARD
web interface. Please see their respective User Manuals for
detailed instructions.
1 . Remove the front panel.
2 . Unscrew and open the battery access door. This screw is
designed to be ïŹxed on the door, do not remove it from the
metal cover.
3. Disconnect the internal battery connector and battery
management module connector.
4. Unscrew the thumbscrew on the battery retention bracket and
then remove it.
Smart App Online EBM for RT 5-6KHD Series
MODEL: BP144VL2U01, BPE144VL2U01
6 . Assemble battery retention cover and the battery connectors.
Tighten the battery access door.
7 . Install the front panels. Execute a battery test via the LCD control
panel. To do this go to the Main Menu and select the Diagnostics
Icon, then select Battery Test and Activate. After the Battery
Test, go back to the Main Menu and select the Set UP icon, then
select Battery Install Date to set the battery installation date. This
operation can also be done via PowerPanelÂź Business Edition
Agent or the RMCARD web interface. Please see their respective
User Manuals for detailed instructions.
1 . Remove the front panel.
2 . Unscrew and open the battery access door. Loosen the two
screws on the battery connectors.
3 . Disconnect the battery and battery management module
connector.
4 . Unscrew the battery retention bracket and then open it.
5 . Pull the battery trays out slowly and then put the new battery
trays into the compartment.
Produktspezifikationen
Marke: | CyberPower |
Kategorie: | Batterie |
Modell: | RB1290X6D |
Brauchst du Hilfe?
Wenn Sie Hilfe mit CyberPower RB1290X6D benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Batterie CyberPower
17 MĂ€rz 2024
22 Januar 2024
24 September 2023
14 September 2023
20 Mai 2023
18 Mai 2023
2 November 2022
14 Oktober 2022
11 Oktober 2022
9 Oktober 2022
Bedienungsanleitung Batterie
- Batterie Hama
- Batterie Kensington
- Batterie Nedis
- Batterie Sandberg
- Batterie Sony
- Batterie Targus
- Batterie Watson
- Batterie LG
- Batterie Bosch
- Batterie Parkside
- Batterie Canon
- Batterie Conrad
- Batterie Black And Decker
- Batterie FERM
- Batterie Ryobi
- Batterie Mestic
- Batterie Hilti
- Batterie Worx
- Batterie Sennheiser
- Batterie Shure
- Batterie Abus
- Batterie Kress
- Batterie Metabo
- Batterie Olympus
- Batterie Scheppach
- Batterie Varta
- Batterie Biltema
- Batterie TOA
- Batterie Tripp Lite
- Batterie Ansmann
- Batterie Husqvarna
- Batterie Scosche
- Batterie Honeywell
- Batterie Nikon
- Batterie Cramer
- Batterie Florabest
- Batterie Zipper
- Batterie Xtorm
- Batterie Vetus
- Batterie Thomann
- Batterie Safescan
- Batterie Milwaukee
- Batterie Toolcraft
- Batterie Huawei
- Batterie Victron Energy
- Batterie EGO
- Batterie Gardena
- Batterie HQ
- Batterie Cobra
- Batterie APC
- Batterie McCulloch
- Batterie Ozito
- Batterie Fluke
- Batterie EnerGenie
- Batterie HĂ€hnel
- Batterie Energizer
- Batterie Variotek
- Batterie Sungrow
- Batterie Growatt
- Batterie SolarEdge
- Batterie Renata
- Batterie LSI
- Batterie Arris
- Batterie Duracell
- Batterie Crestron
- Batterie BlackVue
- Batterie For_Q
- Batterie Bolt
- Batterie Anton/Bauer
- Batterie HART
- Batterie FeinTech
- Batterie Levolta
- Batterie Enerdrive
Neueste Bedienungsanleitung fĂŒr -Kategorien-
8 August 2024
8 August 2024
24 Juni 2024
14 Juni 2024
9 Juni 2024
9 Juni 2024
9 Juni 2024
9 Juni 2024
9 Juni 2024
9 Juni 2024