CyberPower RB1290X16 Bedienungsanleitung

CyberPower Batterie RB1290X16

Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr CyberPower RB1290X16 (3 Seiten) in der Kategorie Batterie. Dieser Bedienungsanleitung war fĂĽr 14 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
1 2 3
123
MODEL: OR1500LCDRM2U, OR2200LCDRM2U, OR1500LCDRTXL2U,
MODEL: PR1000LCD
MODEL: PR1500LCD
1. Remove the front panel of the UPS.
2. Remove two screws from the battery compartment cover and slide the cover completely off of
the unit.
3. Remove the batteries from the compartment. Disconnect the battery wires from the batteries.
4. Install the replacement batteries by connecting the wire bundle (composed of one red wire and
one black wire) to the connector from the battery pack.
5. Put the batteries back into the compartment. Re-install the battery compartment cover and
tighten the retaining screws. Put the front panel back on the UPS.
6. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge
MODEL: PR750LCDRM1U, PR1000LCDRM1U
1. Remove the right side front panel.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Disconnect the black and red cable.
4. Remove the one retaining screw holding the battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
sequence of the above steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR1500SWRM2U, PR2200SWRM2U
1. Remove the right side front panel.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Disconnect the black and red cable.
4. Remove the four retaining screws holding the battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR1000LCDRT2U, PR1000LCDRTXL2U, PR1500LCDRT2U,
PR2200LCDRT2U, PR3000SWRM2U
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the four retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR1000LCDRTXL2Ua, PR1500LCDRTXL2U, PR2200LCDRTXL2U,
PR3000LCDRT2U, PR3000LCDRTXL2Umart
1. Remove the six retaining screws, and remove the front panel from the UPS.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the three retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR5000LCDRTXL5U, PR6000LCDRTXL5U
1. Remove the front panel.
2. Remove the two retaining screws of the cable protection cover and remove the cover.
3. Pull the plastic sticker out slowly to remove the battery module.
4. Put the new battery modules back into the compartment.
5. Tighten the screws and replace the cable protection cover and the front panel.
PFC SINEWAVE Series
MODEL: CP850PFCLCD, CP1000PFCLCD
1. Turn the UPS on its side. Remove the retaining screw located on the bottom of the UPS.
2. Slide the battery compartment cover completely off of the unit.
3. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same
color connectors from the battery pack. Put the batteries back into the compartment.
6. Slide back the battery compartment cover and tighten the retaining screw. Recharge the UPS
for 8-16 hours to fully charge the battery.
MODEL: CP1350PFCLCD
1. Turn the UPS on its side. Remove the front panel retaining screws located on the bottom of the
UPS.
2. Slide the battery compartment cover (front panel) completely off of the unit.
3. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same
color connectors from the battery pack. Put the batteries back into the compartment.
6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS
for 8-16 hours to fully charge the battery.
MODEL: CP1500PFCLCD
1. Turn the UPS on its side. Remove the front panel retaining screws located on the bottom of the
UPS.
2. Slide the battery compartment cover (front panel) completely off of the unit.
3. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
5. Install the replacement batteries by connecting the wire bundle (composed of one red wire and
one black wire) to the connector from the battery pack. Put the batteries back into the
compartment.
6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS
for 8-16 hours to fully charge the battery.
MODEL: OR1500PFCRT2U, OR2200PFCRT2U
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the four retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.


Produktspezifikationen

Marke: CyberPower
Kategorie: Batterie
Modell: RB1290X16
Akku-/Batteriekapazität: 9000 mAh
Breite: 540 mm
Tiefe: 400 mm
Gewicht: 49305 g
Akku-/Batterietechnologie: Plombierte Bleisäure (VRLA)
Höhe: 378 mm
Betriebstemperatur: 0 - 40 °C
Relative Luftfeuchtigkeit in Betrieb: 0 - 90 %
Verpackungsbreite: 642 mm
Verpackungstiefe: 330 mm
Verpackungshöhe: 393 mm
Paketgewicht: 4132625 g
Akku-/Batteriespannung: 12 V
Kompatible Produkte: PR5000LCDRTXL5U, PR6000LCDRTXL5U
Kompatibilität: PR5000LCDRTXL5U, PR6000LCDRTXL5U
Anzahl enthaltener Akkus/Batterien: 16 StĂĽck(e)

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower RB1290X16 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Batterie CyberPower

Bedienungsanleitung Batterie

Neueste Bedienungsanleitung fĂĽr -Kategorien-