CyberPower PR1000ELCDRT2U Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung fĂŒr CyberPower PR1000ELCDRT2U (12 Seiten) in der Kategorie Unterbrechungsfreies Stromversorgungssystem. Dieser Bedienungsanleitung war fĂŒr 42 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
User’s Manual
Professional Rack Mount LCD Series
PR1000ELCDRT2U/PR1500ELCDRT2U/
PR2200ELCDRT2U
K01-0000431- 01
EN
1
Copyright © 2016 CyberPower Systems, Inc.
This manual contains important instructions. Please read and follow all instructions carefully during installation
and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate the
UPS.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection.
DO NOT plug the UPS into an outlet that is not grounded. If you need to power-drain this equipment, turn o
and unplug the unit .
CAUTION! The battery can power hazardous components inside the unit, even when the AC input power is
disconnected.
CAUTION! The UPS should be near the connected equipment and easily accessible.
CAUTION! To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor
area, free of conductive contaminants. (Please see specications for acceptable temperature and humidity
range).
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the battery. an
There are no user serviceable parts inside, except for the battery.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing
the battery or installing a computer com ponent.
CAUTION! To reduce the risk of re, connect the UPS to a circuit with 16 amperes maximum over-current
protection in accordance CE requirement. to
CAUTION! The AC outlet where the UPS is connected should be close to the unit and easily accessible.
CAUTION! Please use only VDE-tested, CE-marked mains cable, (e.g. the mains cable of your equipment),
to connect the UPS to the AC outlet.
CAUTION! Please use only VDE-tested, CE-marked power cables to connect any equipment to the U PS.
CAUTION! When installing the equipment, ensure that the sum of the leakage current of the UPS and the
connected equipment does not exceed 3.5mA.
CAUTION! This is permanently connected equipment and only qualied maintenance personnel may carry
out installations.
CAUTION! Do not unplug the unit from AC Power during operation, as this will invalidate the protective
ground insulation.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! Under no circumstances this
unit should be used for medical applications involving life support equipment and/or patient care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of re, do not use with or near
aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause
the machine to short out.
CAUTION! DO NOT USE WITH LASER PRINTERS! The power demands of laser printers are too large for a
UPS.
DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A
STRONG HEAT SOURCE!
DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING!
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO UPS OUTPUT SOCKETS.
IMPORTANT SAFETY INSTRUCTIONS
2
Copyright © 2016 CyberPower Systems, Inc.
UNPACKING
The box should contain the following:
(1) UPS unit x 1; (2) User manual x 1; (3) Phone line x 1; (4) PowerPanelÂź Business Edition software CD x 1; (5)
USB A+B type cable 1; (6) Rack mount Brackets x 2; (7) Emergency Power O Cable (gray) 1; (8) Serial x x
Interface Cable (DB- 1; (9) Power cord x 4 (Power cord x 6 for PR2200ELCDRT2U) 9) x
AUTOMATIC VOLTAGE REGULATOR(AVR)
The can stabiliz PR1000ELCDRT2U/PR1500ELCDRT2U/PR2200ELCDRT2U
the consistent utility power. The utility power may be damaging to important data
and hardware, but Automatic Voltage Regulation helps the computer not
experience dangerous voltage levels. Automatic Voltage Regulator automatically
regulates low or high voltages keep equipment working at safe AC power levels to
(220/230/240V) without switching to battery. Your equipment can operate normally
even meet the power problems, such as, shout brownouts and blackouts. The
unit’s powerful sealed lead-acid batteries will provide power only if the incoming
voltage drops below 150V or increases above 0V.30
SYSTEM BLOCK DIAGRAM
HARDWARE INSTALLATION GUIDE
1. Battery charge loss may occur during shipping and storage. The rst time the UPS is used, is strongly it
recommended to charge the batteries for at least hours to ensure that the batteries are at theirmaximum 12
charge capacity. To recharge the batteries, simply plug UPSinto an AC outlet, the batteries will charge
whether the UPS is powered on or not.
2. With the UPS o and unplugged, connect your computer, monitor, and any externally powered data
storage device (Hard drive, Tape drive, etc.) into the outlets. DO NOT plug a laser printer, copier, space
heater, vacuum, paper shredder or other large electrical device into the UPS. The power demands
of these devices will overload and possibly damage the unit.
3. To protect a fax, telephone, modem line or network cable, connect the telephone or network cable from the
wall jack outlet to the jack marked “IN” on the UPS. Then, connect a telephone cable or network cable from
the jack marked “OUT” on the UPS to the modem, computer, telephone, fax machine, or network device.
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g.
air conditioner, copier, etc). The warranty prohibits the use of extension cords, outlet strips, and surge
strips.
INSTALLING YOUR UPS SYSTEM (continued)
INSTALLING YOUR UPS SYSTEM (continued)


Produktspezifikationen

Marke: CyberPower
Kategorie: Unterbrechungsfreies Stromversorgungssystem
Modell: PR1000ELCDRT2U
Display-Typ: LCD
Breite: 433 mm
Tiefe: 388 mm
Gewicht: 25500 g
Produktfarbe: Schwarz
Höhe: 88 mm
Energieschutzeigenschaften: Over current, Over power, Over voltage, Overload, Short circuit
Anzahl USB 2.0 AnschlĂŒsse: 1
Betriebstemperatur: 0 - 40 °C
Relative Luftfeuchtigkeit in Betrieb: 0 - 95 %
Anzahl Ethernet-LAN-AnschlĂŒsse (RJ-45): 1
Reaktionszeit: 4 ms
LED-Anzeigen: Leistung
Temperaturbereich bei Lagerung: -15 - 45 °C
Mac-KompatibilitÀt: Ja
Formfaktor: Rackmount/Tower
Kompatible Betriebssysteme: Windows 7/VISTA/XP/2000 Pro/ME/9 8/S e r v e r\n2003/2008, Mac, Linux
Ausgangsleistung: 700 W
Nachhaltigkeitszertifikate: RoHS
Eingangsfrequenz: 50/60 Hz
Anzahl serielle AnschlĂŒsse: 2
Anzahl der AC-AusgÀnge: 8 AC-AusgÀnge
AusgangskapazitÀt: 1 kVA
Modem (RJ-11) Port: 1
AC-Steckertypen: C13-Koppler
Druckanstiegsschutz: Ja
Nominale Eingang Spannung: 150-300 V
Nominale Ausgang Spannung: 230 V
Rack-KapazitÀt: 2U
Notstrom Aus (EPO): Ja
Überspannungsschutz-Funktionen: Fax, Modem

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower PR1000ELCDRT2U benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem CyberPower

Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem

Neueste Bedienungsanleitung fĂŒr -Kategorien-