BAS34U24V
CyberShield UPSs are designed to provide a local power solution for
cable telephony, wireless local loop (WLL), and fiber to the home
(FTTH) broadband equipment.
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack, install, or operate this device.
OVERVIEW
LED INDICATOR
LED Indicator
Ethernet Port LED Indicator
AC Power Cord Connector
DC Output Connector (5W/0.21A)
Universal (Serial) Port
Ethernet Port
External Battery Connector
DC Output Connector(24W/1A)
1
2
3
4
5
6
7
8
Rail Slot
Locking Clip
9
10
1
2
9
10
3
4 5 6 7 8
BATTERY REPLACEMENT AND INSTALLATION
BAS34U24V AND MOUNTING DETAILS
Step 1:
a. Upside down the unit.
b. Loosen four screws from enclosure.
Step 2:
a. Tack away the battery cover.
Step 3:
a. Remove the battery from enclosure.
Step 4:
a. Disconnect the battery cable connector.
b. Install a new battery by connecting the
cable connector.
a.
b.
Step 5:
a. Put the battery back into the compartment.
Step 6:
a. Replace the battery cover.
Step 7:
a. Tighten up four screws from the enclosure.
Mounting on DIN Rail Removing from DIN Rail
Step 8:
a. Upside down the unit to resume normal
operation.
Step 9:
a. Connect the AC cable to activate the unit.
User’s Manual for
CyberShield
STATUS
DC
BATTERY
ETHERNET
PORT
Green
Red
Green
Green
Indicates normal mode of operation.
Indicates the battery is supplying the power.
1.Battery mode : LED is on.
2.Line mode : LED is off.
3.Low battery : LED is blinking.
1.Battery replacement required : LED is on.
2.Battery is absent : LED is blinking.
Yellow The Remote Management Card is connected to the Network.
Indicates the Remote Management Card power.
1.Power on : LED is on.
2.Power off : LED is off.
3.Receiving/transmitting data packet : LED is blinking.
4.Reset finished : LED is blinking.
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
Do not store batteries or battery-powered devices in hot places — elevated temperatures
can lead to capacity loss, leakage, or rupture.
Do not dispose of batteries in a fire. The battery may explode if improperly disposed.
Recycle the battery in accordance with local regulations.
When replacing the battery, the replacement should have the same rating as followers,
18650 Lithium-ion Rechargeable Battery, 14.8V/6500mAh.
Do not remove the cover, except to service the battery, to reduce the risk of electric shock.
To reduce the risk of electric shock, do not remove the cover. No user serviceable parts
inside including the battery. Please contact us or our dealer directly.
Do not disassemble, crush, puncture, or otherwise damage batteries. This can result in
leakage or rupture.
Do not open or mutilate the battery. Released material is harmful to the skin and eyes. It
maybe toxic.
Never block or insert any objects into the keyholes or other openings of the UPS.
To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area, free of conductive contaminants. (Please see specifications for acceptable
temperature and humidity range).
This unit must be DIN rail. Do not use the unit unless it is mounted correctly.
The unit is for indoor use only. Please avoid direct sunlight exposure.
Runtimes based on testing fully-charged, new batteries at normal operating conditions.
Runtime curve is approximate and varies based on battery age, level of charge at test,
environment, and other variables.
As long as utility power is on, you may leave the UPS and connected equipment on while replacing
a new battery. (For service personnel reference only)
Indicator Color
DescriptionNumber
Condition
LIMITED WARRANTY
CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years from the date
Warranty. This Limited Warranty gives you specific rights, and you may have other rights, which vary from State to State or Province to Province.
Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose, if applicable to the Product, is limited in duration to three years. This pr
Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product. NOTE: Some States and Provinces do not allow
so the above limitation may not apply to you.
To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty. Your sole
Limited Warranty. This exclusion of other express warranties applies to written and oral express warranties. CyberPower excludes any liability for perso
indirect, special, incidental, or consequential damages, whether for damage to or loss of property, loss of profits, business interruption, information or d
is caused by negligence or other fault. NOTE: Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damage
DO NOT USE FOR MEDICAL OR LIFE SUPPO EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.RT
CyberPower does not sell the PRODUCT for use in high-risk activities. The PRODUCT is not designed or intended for use in hazardous environments
of nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life support or medical applications or for use in
could lead directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical or life suppo
CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities. CyberPower does not authorize use of any PRODU
ANY SUCH USE IS IMPROPER AND IS MISUSE OF CHARTER PRODUCT. A A
The Limited Warranty is governed by the laws of the United States, without reference to conflict of law principles. The application of the United Nations
Sale of Goods is expressly excluded.
FCC NOTICE :
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
(2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the re
experienced radio/TV technician for help.
CAUTION: Shielded signal cables must be used with this device to ensure compliance with Class A FCC limits.
CAUTION: Any changes or modifications not expressly approved by CyberPower could void the authority granted by the FCC to operate this equipmen
Dimensions (LxWxD)
20.1cm x 12cm x 9.45cm
Weight (Net)
1.3 kg (with 14.8V/6500mAh battery)
Environment
Operating Temperature
Operating Humidity
Max Operating Elevation
CyberPower Systems ( USA ), Inc. 4241 12th Avenue East, Suite 400, Shakopee, MN55379 Phone: (952)403-9500 Fax: (952)403-0009 www.cyberpo
CyberPower Systems ( EUROPE ), Inc. www.cyberpowersystems.com
Deliver spent batteries to a recycling facility or ship to the manufacturer in the
replacement battery packing material.
Max Storage Elevation
Storage Temperature
Signal
Pin
_
AUX_RXD
Output1 +
Output1 -
External _BAT IN +
External _BAT IN -
4
5
6
7
8
This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
Operation of this equipment in a residential environment could cause radio interference.
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to ta
WAMING:
WAMING:
WAMING:
Produktspezifikationen
Marke: | CyberPower |
Kategorie: | Unterbrechungsfreies Stromversorgungssystem |
Modell: | BAS34U24V |
Breite: | 119.8 mm |
Tiefe: | 94.4 mm |
Gewicht: | 1302 g |
Produktfarbe: | Schwarz |
Akku-/Batterietechnologie: | Lithium Polymer (LiPo) |
Höhe: | 200.9 mm |
Betriebstemperatur: | 0 - 40 °C |
Relative Luftfeuchtigkeit in Betrieb: | 0 - 95 % |
Verpackungsbreite: | 169.9 mm |
Verpackungstiefe: | 160.02 mm |
Verpackungshöhe: | 249.9 mm |
Paketgewicht: | 1660 g |
Temperaturbereich bei Lagerung: | 0 - 40 °C |
Akku-/Batteriespannung: | 240 V |
Batteriekapazität: | 6.5 Ah |
Höhe bei Betrieb: | 0 - 3048 m |
Anzahl enthaltener Akkus/Batterien: | - StĂĽck(e) |
Höhe bei Lagerung: | 0 - 15240 m |
Brauchst du Hilfe?
Wenn Sie Hilfe mit CyberPower BAS34U24V benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem CyberPower
22 Mai 2024
27 April 2024
14 April 2024
10 April 2024
7 April 2024
7 April 2024
2 April 2024
1 April 2024
20 März 2024
29 Februar 2024
Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem
- Unterbrechungsfreies Stromversorgungssystem Approx
- Unterbrechungsfreies Stromversorgungssystem HP
- Unterbrechungsfreies Stromversorgungssystem Voltcraft
- Unterbrechungsfreies Stromversorgungssystem Siemens
- Unterbrechungsfreies Stromversorgungssystem Schneider
- Unterbrechungsfreies Stromversorgungssystem Lenovo
- Unterbrechungsfreies Stromversorgungssystem Tripp Lite
- Unterbrechungsfreies Stromversorgungssystem Adj
- Unterbrechungsfreies Stromversorgungssystem JUNG
- Unterbrechungsfreies Stromversorgungssystem Block
- Unterbrechungsfreies Stromversorgungssystem Digitus
- Unterbrechungsfreies Stromversorgungssystem APC
- Unterbrechungsfreies Stromversorgungssystem Eaton
- Unterbrechungsfreies Stromversorgungssystem EnerGenie
- Unterbrechungsfreies Stromversorgungssystem Furman
- Unterbrechungsfreies Stromversorgungssystem Riello
- Unterbrechungsfreies Stromversorgungssystem Steren
- Unterbrechungsfreies Stromversorgungssystem Puls Dimension
- Unterbrechungsfreies Stromversorgungssystem Atlantis Land
- Unterbrechungsfreies Stromversorgungssystem Phoenix Contact
- Unterbrechungsfreies Stromversorgungssystem Middle Atlantic
- Unterbrechungsfreies Stromversorgungssystem Minuteman
- Unterbrechungsfreies Stromversorgungssystem Salicru
- Unterbrechungsfreies Stromversorgungssystem Maruson
- Unterbrechungsfreies Stromversorgungssystem Minute Man
- Unterbrechungsfreies Stromversorgungssystem DEXP
- Unterbrechungsfreies Stromversorgungssystem Bxterra
- Unterbrechungsfreies Stromversorgungssystem Altronix
- Unterbrechungsfreies Stromversorgungssystem FSP
- Unterbrechungsfreies Stromversorgungssystem PowerWalker
- Unterbrechungsfreies Stromversorgungssystem FSP/Fortron
Neueste Bedienungsanleitung fĂĽr -Kategorien-
22 Juni 2024
22 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024